Warning Statements Continued

Installation

WARNING: Installation and servicing of batteries is to be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.

WARNING: Disconnect the battery's ground terminal before working in the vicinity of the battery or battery wires. Contact with the battery can result in electrical shock when a tool accidently touches the positive battery terminal or wire. The risk of such shock is reduced when the ground lead is removed during installation and maintenance.

WARNING: An open bottom stationary engine generator set must be installed over noncombustible materials and shall be located such that it prevents combustible materials from accumulating under the generator set.

WARNING: Installation and repair procedures requires specialized skills with electrical generating equipment and small engine systems. Any person that installs or performs repairs must have these specialized skills to ensure that the generator set is safe to operate. Contact Baldor for installation or repairs.

WARNING: Be sure all wiring complies with the National Electrical Code (NEC) and all regional and local codes or CE Compliance. Improper wiring may cause a hazardous condition and exposure to electrical hazards can cause serious injury or death.

WARNING: Be sure the system is properly grounded before applying power. Do not apply AC power before you ensure that grounds are connected. Electrical shock can cause serious or fatal injury. NEC requires that the frame and exposed conductive surfaces (metal parts) be connected to an approved earth ground. Local codes may also require proper grounding of generator systems.

WARNING: Place protective covers over all rotating parts such as drive shaft, pulley, belt etc. Rotating parts cause extremely dangerous situations because they can catch loose clothing or extremities and cause serious or fatal injury.

WARNING: Unauthorized modification of a generator set may make the unit unsafe for operation or may impair the operation of the unit. Never start a generator set that has been modified or tampered with. Be sure that all covers and guards are properly installed and that the unit is safe before starting the engine. If you are unsure, contact Baldor before starting the engine.

WARNING: When moving the generator, use reasonable caution. Be careful where you place fingers and toes to prevent injury “Pinch Points”. Never try to lift a generator without a hoist or lift means because they are heavy and bodily injury may result.

Warning: Never connect this generator to the electrical system of any building unless a licensed electrician has installed an approved transfer switch. The national electrical code (NEC) requires that connection of a generator to any electrical circuit normally powered by means of an electric utility must be connected by means of approved transfer switch equipment to isolate the electrical circuit from the utility distribution system when the generator is operating. Failure to isolate the electrical circuits by such means may result in injury or death to utility power workers due to backfeed of electrical energy onto the utility lines.

WARNING: Circuit overload protection must be provided in accordance with the National Electrical Code and local regulations.

WARNING: Check Ground Fault Circuit Interrupt (GFCI) receptacles monthly by using the “Test” and “Reset” buttons.

WARNING: Only a professional experienced technician should install a fuel supply system. LPG and natural gas fuels are flammable and can cause fire, explosions, injury or death. Fuel supply lines should be kept away from sharp objects to prevent rupture. Comply with all NFPA regulations and local codes for shut-off valves, regulators, fuel line type, connectors etc.

WARNING: Have electrical circuits and wiring installed and checked by licensed electrician or qualified technician. Electrical shock can cause serious or fatal injury.

WARNING: Incorrect installation of this generator set could result in property damage, injury or death. Connection of the generator to its fuel source must be done by a qualified professional technician or contractor.

WARNING: An open bottom stationary engine generator set must be installed over noncombustible materials and shall be located such that it prevents combustible materials from accumulating under the generator set.

Continued on next page.

1‐4 Product Safety Information

MN2408

Image 8
Contents GLC Generator MN2408California Proposition 65 Warning Table of Contents Appendix B Troubleshooting and Maintenance Problems and SolutionsAppendix a Section Product Safety Information Read This Manual ThoroughlySymbols OperationOperation Warning Statements Burn Installation Battery Safety Maintenance Limited Warranty Warranty PeriodAny warranty coverage Generator Series Labor Parts‐2 General Information MN2408 Installation Guidelines Site PlanningControls and Transfer Switch Engine Cooling SystemExhaust System Room AirVibration Isolators Foundation Design Foundation ChecklistSetting The Genset On An Existing Concrete Floor Slab Weight Of The Genset ‐2 Approximate Weight vs. kW OutputDesigning An Isolated Foundation ‐3 Calculate Soil Bearing Load SBL Capacity‐5 Typical Foundation Installation Soil Type Safe Bearing Capacity Lb per ft Kilo PascalsExhaust System ‐6 Exhaust System Calculations Exhaust Piping Transfer Switch Location Transfer SwitchTransfer Switch Checklist Battery Starting System Battery LocationBattery Charger Battery Cables‐14 General Information MN2408 When the Generator is installed outdoors ‐1 Generator Lifting‐2 Mounting Dimensions ‐3 Stub Up DetailGenerator Open SoundSecure the Generator Ventilation TestGuidelines for Exhaust System Hot Exhaust GassesBackpressure must not exceed 20 of water column Page General Considerations Fuel Connections‐4 Fuel Consumption Natural and LPV External Supply Piping by installer Example Determining Pipe Size for Natural GasNatural Gas Connections Pipe Iron Pipe Size LengthExample Determining Pipe Size for LPV ‐6 LP Vapor Flow Rate Cubic Feet per Hour per Pipe LengthCatalog No Rating Remote Start Transfer Switch ConsiderationsSingle Phase Power Connections Connections AC Power Connections GroundNeutral L1L2 Connections Battery Charger Considerations General Wiring ConsiderationsRecommended Engine Oil and Battery Type GLC10-25GLC100 GLC125Post Installation Checks Post Installation Checks ‐16 Receiving & Installation MN2408 ‐8 Alarm & Warning Conditions Digital Engine Controller Description EM0046A21 MRS17OFF Mode MAN ModeAUT Mode Digital Engine Controller Description EM0046A21 MRS17Adjustment Menu Alarm ListECU Alarm List Menu Status Condition of Transition Action  Next StateAlarms Sensor fail FLS see ‐10Shut down SD see ‐10 ‐10 Possible WarningsInputs and Outputs ‐11 Binary Inputs‐12 Binary outputs Used for shunt trip‐14 Basic Setpoints Set points‐13 Analog Inputs ‐15 Engine Setpoints Delay for Analog Input 2 Wrn Wtemp low. s Range1-180 s ‐15 Engine Setpoints‐16 Engine Protect Setpoints During the first 500ms. ,1s Range 0 3s‐17 Generator Protect Setpoints ‐18 Sensor Spec Setpoints ‐19 IOM/PTM Module Setpoints‐11 Controller Connection Diagram Jdic Alarm LED Speed Signal LEDRun Switch OFF SwitchAutomatic Start/Stop Operator Control PanelManual Start/Stop Automatic Fault Shutdown Automatic Mains Failure AMFUtility Power Failure Conditions Utility Power RestoredUtility Normal Condition Load Test Push-button OperationInternal Faults Digital Input FaultsFault Digital Inputs Name Action Terminal # No Load Test‐15 Engine Controller Inputs & Outputs Analog Faults Fault Inputs Name Action SignalSuch as Fuel Rack Solenoids or electronic governors CrankEngine starter motor Fail Programmable ContactsAction Description Display Comments Apply Power Main LCD Display Reset faultsShow Operating Status screens Name and remaining timeGenerator Phase Voltage Display Line to Line Generator Phase/Neutral Voltage Display Line to NeutralGenerator Phase Current Display Generator Average Output DisplayProgram Menus Navigation Hints Main Menu Loop Voltage Calibration Procedure Zero CalibrationDisplayed values Repeat for each phaseSpan Calibration Oil Pressure Engine Temperature & Oil Pressure CalibrationDisplays the type of calibration function ‐16 Configuration Data Sheet Parameter Setting Range System Voltage Line To Line120-15000V AC Toggle Between Psi/KpaParameter Setting ‐21 Engine Control Connections ‐34 Operation MN2408 General EngineProblem Possible Cause Remedy Problems and Solutions‐1 General Troubleshooting Guide ‐2 Troubleshooting Guide Digital Controller Only Verify the adjustments. Replace controller if failed ‐3 Troubleshooting Guide Analog Controller OnlyService Battery Charger Installation ConsiderationsBattery Options & Accessories A‐1Figure A‐2 Battery Heating Pad Installation BTHTR81 Heater Options & Accessories A‐3 Engine Block HeaterSilencers GLC10-25 GLC30-45 GLC60-90 GLC100-105Fuel Strainer Options & Accessories A‐5Fuel Strainers & Fuel Lines Figure A‐6 Installation StopOptions & Accessories A‐7 Remote AnnuciatorsRadiator Duct Flange GeneratorGLC30-60 GLC80-100Options & Accessories A‐9 EnclosuresGLC10-25 H1=36.0 L1=11.75 GLC30-45 H1=52.1, H2=66.6 GLC60-90 H1=64.2, H2=76.8‐10 Series GLC MN2408 Qty per Phase GLC Circuit Breaker & Electrical DataOSH Plant Series GLC B‐1Figure B‐11 Customer Interface Connection Diagram Series GLC B‐3 Figure B‐13 Single Phase w/o Breaker Connection Diagram Figure B‐14 Single Phase One Breaker Connection Diagram Series GLC B‐5Figure B‐15 Single Phase Two Breaker Connection Diagram Series GLC B‐7 ‐8 Series GLC MN2408 Series GLC B‐9 ‐10 Series GLC MN2408 Figure B‐20 Three Phase Connection Diagram Series GLC B‐11Figure B‐21 Three Phase Connection Diagram with PMG Series GLC B‐13 ‐14 Series GLC MN2408 Series GLC B‐15 ‐16 Series GLC MN2408 Series GLC B‐17 Figure B‐27 Control Box Connections with MEC20 Controller Series GLC B‐19 Figure B‐29 Control Box Connections with MEC2 Controller Figure B‐30 Engine Wiring, Woodward 4.3L GM Series GLC B‐21Figure B‐31 Engine Wiring, Woodward 5.7L GM Figure B‐32 Engine Wiring, Woodward 8.1L GM Series GLC B‐23‐24 Series GLC MN2408 Baldor District Offices Baldor Electric Company MN2408