Liebert 130 kVA user manual 1+N System block diagram with Separate Batteries, Battery

Page 84

User Manual

Hipulse - Single Phase ‘1+N’ UPS System

130 kVA - 110V

Maintenance Bypass

 

 

 

 

 

Isolator Q3

Maintenance Bypass Line

 

 

 

 

 

 

 

 

 

Bypass Isolator Q2

Static Bypass Line

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

 

RECTIFIER

DC Bus

STATIC

Isolator Q4

 

INVERTER

SWITCH

 

 

 

Input

 

 

 

UPS 1

 

 

 

 

Isolator Q1

 

 

 

 

 

 

 

 

Output

 

UPS MODULE 1

3

4

 

Supply

 

 

 

X4

 

 

Battery

Inter Module

Ext.

 

 

BATTERY 1

Sw .

 

 

C.B. 1

Control Bus

Out

 

 

Maintenance Bypass

 

 

 

 

 

Isolator Q3

Maintenance Bypass Line

 

 

 

 

 

 

 

 

 

Bypass Isolator Q2

Static Bypass Line

 

 

 

 

 

 

 

 

 

 

 

 

 

Output

 

RECTIFIER

DC Bus

STATIC

 

Isolator Q4

 

INVERTER

SWITCH

 

 

 

Input

 

 

 

UPS 2

 

 

 

 

Isolator Q1

 

 

 

 

Output

 

UPS MODULE 2

3

4

 

Supply

 

 

 

 

X4

 

 

 

 

 

 

Battery

 

 

Ext.

 

BATTERY 2

Inter Module

 

Sw .

 

C.B. 12

 

 

Control Bus

 

Out

 

UPS MODULE 6

Ext.

Sw .

Out

I N P U T

D I S T R I B U T I O N

UPS 6

Output

Supply

D I S T R I B U T I O N O F L O A D

D I S T R I B U T I O N

P A N E L

Fig 8-1: '1+N' System block diagram with Separate Batteries

64

Image 84
Contents Hipulse Single Phase ‘1+N’ UPS System Hipulse Single Phase ‘1+N’ UPS System Dear Customer Hipulse Single Phase ‘1+N’ UPS System Rev. No Revision details Hipulse Single Phase ‘1+N’ UPS System Registered Head Office Hipulse Single Phase ‘1+N’ UPS System East Zone Hipulse Single Phase ‘1+N’ UPS System Safety Procedure Hipulse Single Phase ‘1+N’ UPS System General Hipulse Single Phase ‘1+N’ UPS System General Introduction Hipulse Single Phase ‘1+N’ UPS System Operating Instructions Hipulse Single Phase ‘1+N’ UPS System Annexure Hipulse Single Phase ‘1+N’ UPS System Single Module block diagram IntroductionDesign Concept Hipulse Module DesignUPS Power switches configuration Bypass SuppliesReturn of power mains Off-BatteryUPS Module fault Normal OperationMaintenance Bypass OverloadUPS Power Switch Configuration Battery circuit breakerBattery temperature compensation System ExpansionHipulse Single Phase ‘1+N’ UPS System Installation Procedure Battery location Environmental considerationsUPS location Mechanical Considerations Installation Drawings Preliminary ChecksOverall General Arrangement for 130kVA Single Phase UPS Cable Entry Details Power Cabling System ConfigurationBattery cables Module input cablesSafety earth Cable ratingGeneral Notes Cable ConnectionsProtection against earth faults RCD devices Protective devicesSplit Bypass UPS Battery Cabling procedureParallel 1+N Input ConnectionsInput-module Parallel Connections Auxiliary Connections+VE -VE Cable connections for 130 kVA 1Ph UPSBattery Control Control cablesAuxiliary Terminal Block detail Auxiliary Terminal Block X3 and X4 at UPS DescriptionBattery Connection Emergency StopBack Feed Protection Hipulse Single Phase ‘1+N’ UPS System Operator Control and Display Panel UPS Operator Control / Display PanelInverter control switch Single module operator control panelOperator control panel Mimic indicationsMenu Control switches Operator Panel and LCD DisplayOutput Parameters Bargraph SelectionEPO on UPS module Menu OptionsMap of screen display available to operator Or. for Instanc eDefault Window LCD Display Panel Messages Initializing WindowInfo Window Main Menu WindowOption Selection Mode Alarm / Warning MessagesGeneral notes Power Switches ShutdownOn Static Bypass Location of Power Isolators Ecomode the message Load on Bypass will not appear Battery C.B. Open Bypass Switch Open Ecomode Your load is now powered via the Static Bypass system Normal OperationYour load is now powered via the Static Bypass system Procedure for completely powering down the UPS UPS is now completely powered down Adding a single module to an existing system If YOU are not Sure What YOU are Doing Then do not do IT Ecomode INV OFF VIA Display Load on Bypass Setting the Battery Test Language Selection Changing the current Date and TimeHipulse Single Phase ‘1+N’ UPS System Battery Installation SafetyUPS Batteries Temperature considerations Battery populationBattery protection Battery RacksConnecting the Battery IntroductionBattery Supply To UPS Cabinet Battery Installation Battery circuit breakerBattery Control and Power Connections Battery temperature Board Display Panel Interpretation LED InterpretationProcedure to carry out the reset see Operating Instructions Sr. No Display Message Alarm Interpretation Display Panel MessagesBypass Switch Open BYP. Absent Battery Under Test BYP Xfer Count Block Hipulse Single Phase ‘1+N’ UPS System + N System General1+N System block diagram with Separate Batteries BatteryInstallation procedure Connection of 1+N system parallel single bus cablesInter-module control Connection of EPO Push Button System Start-up and shutdown procedures Separate Batteries Operating InstructionDefault window Hipulse Single Phase ‘1+N’ UPS System Display Panel message interpretation in 1+N System Complete system shutdownUPS Mechanical Characteristics Conformity and StandardUPS Environmental UPS Electrical Characteristics C T I F I E R I N P U T M a I N SUPS Electrical Characteristics DC Intermediate Circuit Rated Power KVA 130UPS Electrical Characteristics Inverter Output V E R T E R O U T P U TUPS Electrical Characteristics Bypass Input Mains Protection, bypass lineHipulse Single Phase ‘1+N’ UPS System Hipulse Single Phase ‘1+N’ UPS System Hipulse Single Phase ‘1+N’ UPS System Remote Alarm Monitor RAM ConnectionsUPS 220/240V AC 50 HzTermination Indication & MeteringProtection Bypass Isolation Cubicle