Bay Technical Associates DS62-MD4, DS Series manual Unit Configuration Menu, Configuration Status

Page 15

DS62-Network, DS62-MD4 Network/Modem Host Module

Accept changes ? (Y/N) :y

Changes accepted.

Unit Configuration Menu

The configuration menu allows the admin user to establish the parameters the DS-Series will operate.

Configuration

 

 

DS62

module #1

1

DS74

module #2

2

DS-RPC

module #5

3

Enter Request :

 

 

Select the number of the host module and the following menu is displayed:

Copyright(C) Bay Technical Associates 2006

 

DS62-MD4 Ethernet Host module

 

 

 

Revision F 2.10.05

Module 1

509

colilo version 1.05.01

Hardware 1.01

Serial number

Status

1

Current setting of the module

Serial Port Configuration

2

Setup the port configuration menu

Serial Port Device Name

3

Name the port

Attention Character

4

Pressing the attention character 5

 

 

 

consecutive times will return back to the

Disconnect Timeguard

............

5

main menu.

 

If more data is received within the delay

 

 

 

period, the DS series treats the

 

 

 

character as data, not an attention

 

 

 

character; thereby preventing unwanted

Connect Port ID Echo

............

6

port disconnection.

 

Enable port echo by name or module&port#

Login Setup

7

Login menu Access/Users/Direct Port

Network Port Configuration

8

Connection/Radius/TACACS

Network Setup IP Address

Module Name

9

Enter a name for the module

DS Management

..10

Set up Voltage/Current/Sensor thresholds

Firmware / Config Download

11

Updates by FTP & Reset to Factory Config

Exit

X,CR

 

 

Enter Request :

 

 

 

 

Configuration Status

The Status menu displays the modules installed and the current configuration of the host module. The following are the factory default settings:

15

Image 15
Contents DS Series Manual DS62-Network, DS62-MD4 Network/Modem Host Module EIA-232 Serial Connection DS62-Network, DS62-MD4 Network/Modem Host Module DS62-Network, DS62-MD4 Network/Modem Host Module Installation Connection DescriptionInternal Modem Connection Quick Start Host Module PowerSerial Setup DS-DS Access Control Login Setup MenuRadius Configuration Network Port ConfigurationCabling DS62 EIA-232 RJ-45 Signal Pin DirectionAdapters Signals Description Signal RS-232 COM Port Port DS Port RPC DE-9 Pin DB-25 PinAdapters Main Screen Detail Operations and ConfigurationsConfiguration Status Unit Configuration MenuDTR RTS Serial Port Configuration Default is NoneHandshaking Word Size Baud RateDS62-Network, DS62-MD4 Network/Modem Host Module Stop Bits ParityRTS/DTR Line Driver Inactivity State Connect Port ID Echo Default setting is DisabledSerial Port Device Name Disconnect TimeguardLogin Setup Menu Access ControlManage Users ADD User Change User’s Port Access and PasswordSelect a non-root user and the DS displays Radius Configuration Direct Port ConnectionDelete User Tacacs Configuration Tacacs Network Port Configuration Subnet Mask IP AddressBreak Length Inactivity TimeoutGateway Address Carriage Return TranslationSSH Host Key Generation IP Filter ConfigurationSelect F, Flush Rules to delete all rules. The DS displays Snmp Configuration Read/Write Community String Default is zero minutes Web Server ConfigurationDefault is Disabled Default is EnabledInternal Alarm Threshold Module NameDS Management Select 1, the DS displays External Alarm ThresholdOutlet Groups Select 6, Delete All Outlet Groups and the DS displays Enable Firmware Upgrade Firmware / Config DownloadEnable Configuration File Upload Get Current Configuration File Restore Configuration DefaultsDisplay Configuration Error Log DS62-MD4 Modem Configuration MenuModem Host V90 Modem 9600 None None LO LO Modem Device Name Status Menu Overall System StatusNetwork Status Logged Users Memory UsageCurrent Routing Cache Processes Route SetupUnit Reset LogoutUnitInfo Database Functional Solutions TroubleshootingDS62/DS62-MD4 DS62 and DS62-MD4 Reset procedureExceptions BayTech Product WarrantyEmail support@baytech.net Technical SupportReturn Authorization Process