Bay Technical Associates DS Series, DS62-MD4 manual Serial Setup

Page 8

DS62-Network, DS62-MD4 Network/Modem Host Module

5.Select ‘C’ for the configuration menu.

6.Select the HOST module. You should see a menu similar to (Figure 2).

7.Select the number for ‘Login Setup’ option. You should see a menu similar to (Figure 3).

8.Select the number for ‘Manage Users’ option. You should see a menu similar to (Figure 4).

9.NOTE: The ‘root’ user can not be deleted.

10.Select ‘A’ to add user. Type the name and password at the prompts.

11.Press ‘Enter’ until get to the ‘Login Setup Menu’ (Figure 3).

12.Select option ‘Access Control’ to enable or disable the Tenet and Serial Login Prompt.

13.Press ‘Enter’ until you get the Configuration menu (Figure 2).

14.Select ‘Network Port Configuration’ option. You should see a menu similar to (Figure 5).

15.If your System Administrator requires you to use DHCP, then select ‘DHCP Enable/Disable’ and type ‘Y’ to enable DHCP. If you wish to assign a static IP address to this unit, disable the DHCP and go to step 18.

16.Press ‘Enter’ until you are asked to ‘Accept Changes’. Type ‘Y’ to accept changes or ‘N’ to decline changes.

17.After Accepting or Declining Changes Pres ‘Enter ‘ until you get the Network Access Menu (Figure 1).

18.Select ‘Unit reset’ to update the external connections. Once the reset is completed (1 minute) connect the Baytech device to your network using an Ethernet cable.

19.If you disabled the DHCP in step 15, you should see a menu similar to (Figure 5).

20.Select the ‘IP Address’ option and type the assigned IP address and press ‘Enter’.

21.Select the ‘Subnet Mask’ option and type the assigned subnet mask address and press ‘Enter’.

22.Select the ‘Gateway Address’ option and type the assigned Gateway address and press ‘Enter’.

23.Press ‘Enter’ until you are asked to ‘Accept Changes’. Type ‘Y’ to accept changes.

24.Press ‘Enter’ until you get the Network Access Menu, (Figure 1).

25.Select ‘Unit reset’ to update the external connections. Once the reset is completed (1 minute) connect the Baytech device to your network using an Ethernet cable.

At this point you have enough basic configurations needed to operate this Baytech unit.

Serial Setup

Verify JMP5 is set to pins 1 and 2 on the DS62 module.

Connect the 9FRJ45PC-4adapter to the user’s computer

Connect the Host Module’s EIA-232 port to the adapter via the RJ08X007 rolled flat ribbon cable.

Use terminal emulation software to access the unit, 9600 bps, 8 data bits, 1stop bit and no parity.

NOTE: At any time during the session you need to go to another menu, use the Attention Character = semi-colon (;). Press the attention character key 5 consecutive times to get back to the main status menu.

8

Image 8
Contents DS Series Manual DS62-Network, DS62-MD4 Network/Modem Host Module EIA-232 Serial Connection DS62-Network, DS62-MD4 Network/Modem Host Module DS62-Network, DS62-MD4 Network/Modem Host Module Internal Modem Connection InstallationConnection Description Power Quick Start Host ModuleSerial Setup DS-DS Login Setup Menu Access ControlNetwork Port Configuration Radius ConfigurationDS62 EIA-232 RJ-45 Signal Pin Direction Adapters Signals DescriptionSignal RS-232 COM Port Port DS Port RPC DE-9 Pin DB-25 Pin CablingAdapters Detail Operations and Configurations Main ScreenUnit Configuration Menu Configuration StatusDTR RTS Handshaking Serial Port ConfigurationDefault is None Baud Rate Word SizeRTS/DTR Line Driver Inactivity State DS62-Network, DS62-MD4 Network/Modem Host Module Stop BitsParity Default setting is Disabled Serial Port Device NameDisconnect Timeguard Connect Port ID EchoManage Users Login Setup MenuAccess Control Change User’s Port Access and Password ADD UserSelect a non-root user and the DS displays Delete User Radius ConfigurationDirect Port Connection Tacacs Configuration Tacacs Network Port Configuration IP Address Subnet MaskInactivity Timeout Gateway AddressCarriage Return Translation Break LengthIP Filter Configuration SSH Host Key GenerationSelect F, Flush Rules to delete all rules. The DS displays Snmp Configuration Read/Write Community String Web Server Configuration Default is DisabledDefault is Enabled Default is zero minutesDS Management Internal Alarm ThresholdModule Name External Alarm Threshold Select 1, the DS displaysOutlet Groups Select 6, Delete All Outlet Groups and the DS displays Firmware / Config Download Enable Firmware UpgradeEnable Configuration File Upload Restore Configuration Defaults Get Current Configuration FileDS62-MD4 Modem Configuration Menu Display Configuration Error LogModem Host V90 Modem 9600 None None LO LO Modem Device Name Network Status Status MenuOverall System Status Current Routing Cache Logged UsersMemory Usage Route Setup ProcessesUnitInfo Database Unit ResetLogout Troubleshooting Functional SolutionsDS62 and DS62-MD4 Reset procedure DS62/DS62-MD4BayTech Product Warranty ExceptionsTechnical Support Email support@baytech.netReturn Authorization Process