DS62-Network, DS62-MD4 Network/Modem Host Module

DTR Line Driver Inactive State is: High

High ? (Y/N, CR for no change):

Serial Port Device Name

Select a port and type the new name.

Current device name: EIA-RS232

Enter device name for serial port ((1 - 16 char., CR to end) :

Attention Character

Pressing the Attention Character 5 consecutive times will access the network main menu. The Default is a semi-colon (;). Select this option to change the attention character. The DS displays the following:

Attention Character is

;

Enter Attention Character :

Disconnect Timeguard

This feature ensures reliable binary data transmission by providing a one-second “Timeguard” after the DS-Series receives the attention character. If more data is received within the delay period, the DS treats the character as data, not an attention character; thereby preventing unwanted port disconnection.

The Default setting is Disabled.

Disconnect Time

Guard is

Disabled

Enable ? (Y/N),

CR for no change) :

 

Connect Port ID Echo

When a user logs into the DS unit the port is identified in the following example:

BAYTECH

For further information check:

http://www.baytech.net/

DS62

<=

Device

name Port echo.

 

or

<=

 

 

 

02,1

Module

and Port Number

echo.

Select option 1, to disable the echo. The Default setting is Disabled.

Select option 2 to echo the module and port number. (i.e. 3, 2)

Select option 3 to echo the device name. (Device A)

20

Image 20
Contents DS Series Manual DS62-Network, DS62-MD4 Network/Modem Host Module EIA-232 Serial Connection DS62-Network, DS62-MD4 Network/Modem Host Module DS62-Network, DS62-MD4 Network/Modem Host Module Internal Modem Connection InstallationConnection Description Power Quick Start Host ModuleSerial Setup DS-DS Login Setup Menu Access ControlNetwork Port Configuration Radius ConfigurationDS62 EIA-232 RJ-45 Signal Pin Direction Adapters Signals DescriptionSignal RS-232 COM Port Port DS Port RPC DE-9 Pin DB-25 Pin CablingAdapters Detail Operations and Configurations Main ScreenUnit Configuration Menu Configuration StatusDTR RTS Handshaking Serial Port ConfigurationDefault is None Baud Rate Word SizeRTS/DTR Line Driver Inactivity State DS62-Network, DS62-MD4 Network/Modem Host Module Stop BitsParity Default setting is Disabled Serial Port Device NameDisconnect Timeguard Connect Port ID EchoManage Users Login Setup MenuAccess Control Change User’s Port Access and Password ADD UserSelect a non-root user and the DS displays Delete User Radius ConfigurationDirect Port Connection Tacacs Configuration Tacacs Network Port Configuration IP Address Subnet MaskInactivity Timeout Gateway AddressCarriage Return Translation Break LengthIP Filter Configuration SSH Host Key GenerationSelect F, Flush Rules to delete all rules. The DS displays Snmp Configuration Read/Write Community String Web Server Configuration Default is DisabledDefault is Enabled Default is zero minutesDS Management Internal Alarm ThresholdModule Name External Alarm Threshold Select 1, the DS displaysOutlet Groups Select 6, Delete All Outlet Groups and the DS displays Firmware / Config Download Enable Firmware UpgradeEnable Configuration File Upload Restore Configuration Defaults Get Current Configuration FileDS62-MD4 Modem Configuration Menu Display Configuration Error LogModem Host V90 Modem 9600 None None LO LO Modem Device Name Network Status Status MenuOverall System Status Current Routing Cache Logged UsersMemory Usage Route Setup ProcessesUnitInfo Database Unit ResetLogout Troubleshooting Functional SolutionsDS62 and DS62-MD4 Reset procedure DS62/DS62-MD4BayTech Product Warranty ExceptionsTechnical Support Email support@baytech.netReturn Authorization Process