Panasonic WJ-FS616C manual DIP Switch Setting, Alarm Output Setting, Dummy Black Image Setting

Page 14

DIP Switch Setting

Alarm Output Setting

The following settings let you set the polarities of alarm out- put, alarm reset output, and alarm & SW output on the ALARM/REMOTE port.

1.Disassemble the video multiplexer as described for installing the Data Multiplex Boards on page 12.

2.Set switches (SW3/SW4/SW5) on the board to the required position either Open Collector (O.C) or Pulse (0/5V) for alarm control signals.

Open Collector (O.C): 16V DC 100 mA max.

Pulse (0/5V): +5V DC approx. 500 ms

The positions in the figure are the factory default setting.

• Timing Table of the signals (0/5 V settings)

0/5V

 

 

O.C

SW3 : Alarm Output

 

 

SW5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW4 : Alarm Reset Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW5 : Alarm & SW Output

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW3

 

 

SW4

 

0/5V

 

 

O.C 0/5V

 

O.C

 

 

 

 

 

 

 

100 ms or more

 

100 ms or more

 

Alarm input 1

 

Hi-Z

0V

Hi-Z

0V

Hi-Z

Alarm input 2

 

 

 

Hi-Z

0V

Hi-Z

 

 

 

 

 

Retrigger

 

 

 

 

Alarm output time

 

Alarm output time

Alarm output

5V

 

 

 

 

 

0V

 

 

 

C

 

(Pin #9)

 

 

 

 

 

 

 

 

 

 

 

Alarm reset

5V

 

 

 

Approx.

 

 

 

 

 

450 ms

 

output (Pin #27) 0V

 

 

 

 

 

Alarm & SW

5V

 

Approx 100 ms

 

 

 

 

 

 

 

 

 

Output (Pin #25) 0V

 

 

 

 

 

CIf another alarm is received before the existing alarm is reset, the alarm output lasts as long as the duration set for the succeeding alarm.

The O.C position of SW3, SW4, and SW5 corresponds to their 0/5 V position as shown in the table.

Terminal condition

OFF

ON

SW

 

 

O.C position

Hi-Z

0 V

 

 

 

0/5 V position

0 V

5 V

 

 

 

Dummy Black Image Setting

According to the factory default setting, the Dummy Black Image signal is supplied to the REC OUT con- nector as needed to overwrite any image displayed by error. If this function is not required, set the switch SW 1 to the position shown below.

1.Disassemble the video multiplexer as described for installing the Data Multiplex Boards on page 12.

2.Set switch (SW1) on the board to the position shown in the figure.

SW1

OFF

SW1 : Record Output

14

Image 14
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Features PrefaceDo not drop metallic parts through slots PrecautionsFully charge up the backup battery Do not attempt to disassemble the applianceAlarm Reset Button Reset Power Switch Power ON/OFFLock Indicator Lock Alarm Indicator AlarmSpot Monitor Button Spot Camera Number Buttons Camera Preset Position Number Buttons@2Preset Position Button PRE-POSI Multiscreen Monitor Button Multiscreen@6Direction Buttons UP/DOWN/LEFT/RIGHT #1Setup/Escape Button SET UP/ESC#2Lock Switch Lock OFF/ON Left Left Right Right @7Auto Button Auto$4Line Termination Switch TERM., OFF/ON $1Camera Output Connectors Camera OUT$2Camera Input Connectors Camera $5Line Selection Switch Line SELECT, 2/48Data Port DATA, OUT/IN Installation Installing the WV-PB6164 Data Multiplex BoardsTally Output Setting Dummy Black Image Setting DIP Switch SettingAlarm Output Setting Mounting into the Rack Connections Shown below is an example of a basic system connectionConnection with the Camera Sites Connections for RS-485 type camera Data port Connection with the MonitorsConnection with the PC RS-232CConnection with Alarm Sensors Connection with External Remote Control SwitchesMonitors and Displays Spot and Multiscreen MonitorConnection with the Time Lapse VCR Connect the time lapse VCR as shown in the example belowSetup Procedures Setup Menu Displaying the Setup MenuProgramming Setup Menu Setup MenuAlarm Schedule Alarm SetupAlarm Recall Camera Switching Pulse Loss Alarm Camera Site AlarmVideo Loss Alarm Alarm Display on the MonitorsAlarm Recording Mode Alarm Mode on the Multiscreen MonitorAlarm Mode on the Spot Monitor Dwell Time for Alarm SequenceClock Display Multiscreen Output SetupCamera Title Display Still DisplaySecret View Camera Display Position SettingSequence Mode Spot Output Setup Camera Title Display Record or Multiscreen 2 Output SetupRecord Output Setup Clock DisplayDynamic Recording Recording Mode SetupRecording Mode Setting Details Multiscreen 2 Output Setup Sequence Mode Camera Display PositionClock Display Position System SetupClock Setup Camera Title Display Position Camera Title SetupSequence Setup Spot Sequence SEQ1Image Assignment Preset PositionAuto Skip Dwell Time Uniform Dwell TimeDwell Time Multi Sequence SEQ2, SEQ3Camera/Playback Sequence Timing Spot Monitor Lock ModeSequence Timing Multiscreen Monitor Programming Steps 2 toAlarm Terminal Setup Cable Compensation/VD2/DataRS-232C Mode Playback ModeData Mode Communication Port SetupUnit Address Daisy ModeVCR Input Select Password Password RegistrationCamera Upload Other Setup MenusCamera Download All Reset Operating Procedures Single Sequence Live Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Spot LiveSingle Spot Live Selecting the Multiscreen MonitorControlling the Camera Images Freezing Single Spot LiveFreezing Multiscreen Spot Live Zooming Single Spot LiveMultiscreen Spot Live Controlling the Playback Images Single or Multi Sequence LiveSingle Spot Playback Freezing Single Spot PlaybackFreezing Multiscreen Spot Playback Zooming Single Spot PlaybackMultiscreen Spot Playback Single or Multi Sequence PlaybackDisplaying the Camera and Playback Images Multiscreen Spot Live Images with a Playback ImageFreezing Multiscreen Spot Live Images with a Playback Image Camera Selection Controlling Camera Site AccessoriesCamera Control Function Lens ControlPan/Tilt Control Home Position Pan/Tilt Control Preset OperationCamera Setup Pan/Tilt Control Auto PanningSimplified preset position setting Alarm Operation Alarm Control FunctionAlarm Input Multiscreen Output Spot OutputAlarm Reset Example of Using Multiscreen 2 MonitorAlarm Suspension Reset SpotRecording on the Time Lapse VCR Camera Switching Pulse Loss DisplayOther Function Operating Procedures with WV-CU550C System Controller WV-CU550C Major Operating Controls and Their FunctionsTime Lapse Mode Buttons T/L MODE, D C Busy Indicator BusySet Up button SET UP D 5Preset Position Button PRE-POSI@5Controller Unit Number switch Controller Unit no @2Alarm Reset button Reset@4Termination switch TERM., ON/OFF @6Mode Selection switch ModeConnection with the WV-CU550C System Controller InstallationsModifying the Front Panel Setup Menu Operations with WV-CU550C WJ-FS616C WV-CU550C FunctionFunction Operations with WV-CU550C Controlling the Video Input and MonitorsCamera Control Function RES A.RES Alarm Control Function Auxiliary ControlSystem Expansion Other Applications Operating ProcedureConnections ApplicationFor Local Site For Main SiteAppendix Transmission CommandResponse Command Communication ProtocolCommand Table Transmission Response Parameter Ascii Command AsciiQOP Table below 19 kinds NoneResponse Command Ascii Main Unit Information Specifications Standard AccessoriesPanasonic Canada Inc