Panasonic WJ-FS616C manual Command Table, Transmission Response Parameter Ascii Command Ascii

Page 78

Command Table

(1) Operation Control

Item

Transmission

Response

 

Parameter (ASCII)

Command (ASCII)

Command (ASCII)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m=0

Spot Monitor

 

Monitor Select

OMS : m

OMS

m=1

Multiscreen Monitor

 

 

 

m=2

Multiscreen 2 Monitor

 

 

 

 

 

 

VCR/Camera Select

OVC : m

OVC

m=0

Camera Mode

 

m=1

VCR Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m=0

Still OFF

 

 

Still ON/OFF

OST : m : nn

OST

m=1

Still ON

 

 

nn=00 All video channels specify

 

 

 

 

 

 

nn=01 - 16 Camera Number

 

 

 

 

 

 

 

 

 

 

m=0

Quad

m=1

7 divide

Multiscreen Select

OTC : m

OTC

m=2

9 divide

m=3

10 divide

m=4

13 divide

m=5

16 divide

 

 

 

 

 

 

m=1

No. of divisions (+) m=D

No. of divisions ()

 

 

 

 

 

 

Sequence

OSQ : m

OSQ

m=0

End Sequence

 

m=1

Activate Sequence

 

 

 

 

 

 

 

 

 

 

Sequence Mode

 

 

m=0

SEQ1

 

 

OSE : m

OSE

m=1

SEQ2

 

 

Select

 

 

 

 

m=2

SEQ3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electronic Zoom

OZM : m

OZM

m=0

Zoom OFF

 

 

ON/OFF

m=1

Zoom ON

 

 

 

 

 

 

 

 

 

 

Single Spot CH Select

OCS : mm

OCS

mm=00 - 16 Camera Number

*00=Spot Input

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Camera & Playback Display

OVS : mm

OVS

mm=01 - 16 Playback CH number

Playback CH Select

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

m=0

1CH Alarm

 

Alarm Input

OAI : m

OAI

:

 

 

 

 

 

 

m=F

16CH Alarm

 

 

 

 

 

 

 

Alarm Reset

OAL : m

OAL

m=0

Manual Reset

 

m=1

Auto Reset

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Log Clear

OAR

OAR

None

 

 

 

 

 

 

 

 

 

 

Note: If a command has no parameter value, it is processed with the value under lined in the table.

(2) Mode Change

Item

Transmission

Response

 

Parameter (ASCII)

Command (ASCII)

Command (ASCII)

 

 

 

 

 

 

 

 

 

Alarm Suspension

MAD : m

MAD

m=0

Alarm Suspension OFF

m=1

Alarm Suspension ON

 

 

 

 

 

 

 

 

Lock *1

MKL : m

MKL

m=0

Lock OFF

m=1

Lock ON

 

 

 

 

 

 

 

 

Setup

MSU : m

MSU

m=0

End Setup

m=1

Begin Setup

 

 

 

 

 

 

 

 

*1: The LOCK (key lock) command is used to prohibit operations on the panel of the Video Multiplexers and the System Controllers. After execution of this command, only the personal computer can operate the system.

79

Image 78
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Features PrefaceDo not drop metallic parts through slots PrecautionsFully charge up the backup battery Do not attempt to disassemble the applianceAlarm Reset Button Reset Power Switch Power ON/OFFLock Indicator Lock Alarm Indicator AlarmSpot Monitor Button Spot Camera Number Buttons Camera Preset Position Number Buttons@2Preset Position Button PRE-POSI Multiscreen Monitor Button Multiscreen@6Direction Buttons UP/DOWN/LEFT/RIGHT #1Setup/Escape Button SET UP/ESC#2Lock Switch Lock OFF/ON Left Left Right Right @7Auto Button Auto$4Line Termination Switch TERM., OFF/ON $1Camera Output Connectors Camera OUT$2Camera Input Connectors Camera $5Line Selection Switch Line SELECT, 2/48Data Port DATA, OUT/IN Installation Installing the WV-PB6164 Data Multiplex BoardsTally Output Setting DIP Switch Setting Alarm Output SettingDummy Black Image Setting Mounting into the Rack Connections Shown below is an example of a basic system connectionConnection with the Camera Sites Connections for RS-485 type camera Data port Connection with the MonitorsConnection with the PC RS-232CConnection with Alarm Sensors Connection with External Remote Control SwitchesMonitors and Displays Spot and Multiscreen MonitorConnection with the Time Lapse VCR Connect the time lapse VCR as shown in the example belowSetup Procedures Setup Menu Displaying the Setup MenuProgramming Setup Menu Setup MenuAlarm Setup Alarm RecallAlarm Schedule Camera Switching Pulse Loss Alarm Camera Site AlarmVideo Loss Alarm Alarm Display on the MonitorsAlarm Recording Mode Alarm Mode on the Multiscreen MonitorAlarm Mode on the Spot Monitor Dwell Time for Alarm SequenceClock Display Multiscreen Output SetupCamera Title Display Still DisplayCamera Display Position Setting Sequence ModeSecret View Spot Output Setup Camera Title Display Record or Multiscreen 2 Output SetupRecord Output Setup Clock DisplayRecording Mode Setup Recording Mode Setting DetailsDynamic Recording Multiscreen 2 Output Setup Sequence Mode Camera Display PositionSystem Setup Clock SetupClock Display Position Camera Title Display Position Camera Title SetupSequence Setup Spot Sequence SEQ1Image Assignment Preset PositionAuto Skip Dwell Time Uniform Dwell TimeMulti Sequence SEQ2, SEQ3 Camera/PlaybackDwell Time Sequence Timing Spot Monitor Lock ModeSequence Timing Multiscreen Monitor Programming Steps 2 toAlarm Terminal Setup Cable Compensation/VD2/DataRS-232C Mode Playback ModeData Mode Communication Port SetupDaisy Mode VCR Input SelectUnit Address Password Password RegistrationOther Setup Menus Camera DownloadCamera Upload All Reset Operating Procedures Single Sequence Live Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Spot LiveSingle Spot Live Selecting the Multiscreen MonitorControlling the Camera Images Freezing Single Spot LiveZooming Single Spot Live Multiscreen Spot LiveFreezing Multiscreen Spot Live Controlling the Playback Images Single or Multi Sequence LiveSingle Spot Playback Freezing Single Spot PlaybackFreezing Multiscreen Spot Playback Zooming Single Spot PlaybackMultiscreen Spot Playback Single or Multi Sequence PlaybackDisplaying the Camera and Playback Images Multiscreen Spot Live Images with a Playback ImageFreezing Multiscreen Spot Live Images with a Playback Image Camera Selection Controlling Camera Site AccessoriesCamera Control Function Lens ControlPan/Tilt Control Home Position Pan/Tilt Control Preset OperationCamera Setup Pan/Tilt Control Auto PanningSimplified preset position setting Alarm Control Function Alarm InputAlarm Operation Multiscreen Output Spot OutputAlarm Reset Example of Using Multiscreen 2 MonitorAlarm Suspension Reset SpotCamera Switching Pulse Loss Display Other FunctionRecording on the Time Lapse VCR Operating Procedures with WV-CU550C System Controller WV-CU550C Major Operating Controls and Their FunctionsTime Lapse Mode Buttons T/L MODE, D C Busy Indicator BusySet Up button SET UP D 5Preset Position Button PRE-POSI@5Controller Unit Number switch Controller Unit no @2Alarm Reset button Reset@4Termination switch TERM., ON/OFF @6Mode Selection switch ModeInstallations Modifying the Front PanelConnection with the WV-CU550C System Controller Setup Menu Operations with WV-CU550C WJ-FS616C WV-CU550C FunctionFunction Operations with WV-CU550C Controlling the Video Input and MonitorsCamera Control Function RES A.RES Alarm Control Function Auxiliary ControlSystem Expansion Other Applications Operating ProcedureConnections ApplicationFor Local Site For Main SiteAppendix Transmission CommandResponse Command Communication ProtocolCommand Table Transmission Response Parameter Ascii Command AsciiQOP Table below 19 kinds NoneResponse Command Ascii Main Unit Information Specifications Standard AccessoriesPanasonic Canada Inc