4.Select the preset position number to be assigned in the PRE column by pressing the - or + button.
5.Repeat steps 2 to 4 above to assign other terminal numbers.
Note: The same channel number can be assigned to multiple alarm terminals.
In this case, different preset positions can be assigned, but when alarm occurs at these positions, the camera movHes to the preset position where the most recent alarm occurred.
6.Press the [SET UP/ESC] button to execute the settings and returns to the previous SYSTEM SETUP menu.
■Playback Mode
This item lets you select the ID code for playback of record- ed videotape.
1.Move the cursor to the PLAYBACK MODE parameter in the SYSTEM SETUP menu.
2.Select either FIELD or FS10.
FIELD: Normally set to this position.
FS10: Enables playback of the videotape that is record- ed with the
The factory default setting is FIELD.
■Data Mode
This item lets you select an external controller from the DATA port.
1.Move the cursor to the DATA MODE parameter in the SYSTEM SETUP menu.
2.Select either CU or PC.
CU: Enables control from the specified System Controller.
PC: Enables control from a PC.
The factory default setting is CU.
■RS-232C Mode
This item lets you select the
1.Move the cursor to the
2.Select either VCR or PC.
VCR: Enables use as VCR control port.
PC: Enables use as external control port from a PC.
The factory default setting is VCR.
Note: Be sure to select PC in this menu if you plan to use the REMOTE OUT connector for control- ling the VCR.
■Communication Port Setup
This item lets you set the parameters for communication between the ports and the connected appliances.
1.Move the cursor to COM PORT SETUP in the SYSTEM menu, then press the [HOME/SET] button.
The COM PORT SETUP table shown in the figure appears on the monitor screen.
| COM PORT SETUP |
| |||
| DATA | ||||
DELAY |
| OFF |
| OFF | OFF |
BAUD RATE | 9600 | 9600 | 19200 | ||
WAIT TIME |
| OFF | 100 | OFF | |
DATA BIT | 7 |
| 8 | 8 | |
PARITY |
| ODD | EVEN | NONE | |
STOP BIT | 1 |
| 1 | 1 | |
XON/XOFF | - |
| OFF | OFF | |
FULL/HALF | - |
| - | FULL |
2.Move the cursor to the port column you want to edit by pressing the C, D, A or B button.
The table indicates the factory default settings.
3.Select the desired delay time for DELAY by pressing the - or + button.
↔ OFF ↔ 10 ↔ 20 ↔ 40 ↔ 60 ↔ 80 ↔ 100 ↔
4.Select the desired transmission speed (bits per sec- ond) for BAUD RATE by pressing the - or + button.
↔ 1 200 ↔ 2 400 ↔ 4 800 ↔ 9 600 ↔ 19 200 ↔
42