Panasonic WJ-FS616C manual Connections, Other Applications, Operating Procedure

Page 75

Connections

In this type of installation, only one video multiplexer is con- nected directly to the system controller by a control cable. The rest of the video multiplexers are connected to the sys- tem controller in a daisy-chain type connection.

Refer to the connections and data port settings shown below.

 

Local Site

 

Main Site

 

 

 

 

 

 

 

Video Multiplexer

 

Video Multiplexer

 

 

 

 

 

 

 

 

WJ-FS616C

 

 

WJ-FS616C

 

 

 

 

 

 

 

SPOT

 

 

SPOT

 

 

 

 

 

 

 

OUT

I N

 

OUT

I N

 

 

 

 

 

 

 

 

OUT

DATA

 

OUT

DATA

 

DATA

CONTROLLER

 

IN

 

IN

IN

OUT

 

UNIT NO.

 

 

TEAM.

 

 

TEAM.

 

 

 

OFF ON

 

 

OFF ON

 

TERM

9

0

1

 

 

 

 

 

 

 

1-8

 

 

 

 

 

 

 

ON

OFF

8

 

2

 

 

 

 

 

 

 

7

 

3

 

 

 

 

 

 

 

 

 

6

5

4

For example, press the keys shown below.

2

MON

1

5

CAM

 

UNIT/ESC

 

 

SET

In this example, the image of camera 15 connected to the video multiplexer Unit 2 is displayed on the Spot Monitor connected to the video multiplexer Unit 1.

5.Operate the selected unit as described in the OPERAT-

ING PROCEDURES.

6.Select another unit with the Numeric key, then press the [MON(UNIT/ESC)] key to activate the selected unit.

Notes:

Up to four video multiplexers can be daisy-chained to the system controller.

Unit numbers should be assigned in the order of connection, starting with the unit connected directly to the WV-CU550C system controller.

Sequence display is limited to the cameras con- nected to one multiplexer unit only.

It is recommended to set the LOCK switch to the ON position while making these connections.

For controlling more than 4 cameras, additional WV- BP6164 Data Multiplex Boards need to be installed in the video multiplexer.

Other Applications

Application 1

The video signal looped through the SPOT IN connector can be displayed on the Spot Monitor.

VIDEO

VIDEO

Unit 2

Unit 1

Operating Procedure

To control the system, follow the procedure shown below.

1.Confirm that the camera and peripherals are connected correctly and firmly.

2.Turn on the power switches of all system components.

3.Confirm that the DAISY MODE parameter in the SYS- TEM SETUP menu is set to ON.

4.Select the unit number of the video multiplexer with the Numeric key, then press the [MON(UNIT/ESC)] key to activate the selected unit.

1 2 3

4 5 6

7 8 9

MON 0 CAM

UNIT/ESC SET

1.Confirm that the DAISY MODE in the SYSTEM SETUP menu is set to OFF.

2.Select the unit number of the video multiplexer with the Numeric key, then press the [MON(UNIT/ESC)] key to activate the selected unit.

3.Press the [F2] button on the controller to select the spot monitor.

4.Press [ 0 ] then press the [CAM(SET)] key to display the video looped through the SPOT IN connector on the Spot Monitor.

76

Image 75
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Preface FeaturesDo not attempt to disassemble the appliance PrecautionsFully charge up the backup battery Do not drop metallic parts through slotsAlarm Indicator Alarm Power Switch Power ON/OFFLock Indicator Lock Alarm Reset Button ResetMultiscreen Monitor Button Multiscreen Camera Number Buttons Camera Preset Position Number Buttons@2Preset Position Button PRE-POSI Spot Monitor Button SpotLeft Left Right Right @7Auto Button Auto #1Setup/Escape Button SET UP/ESC#2Lock Switch Lock OFF/ON @6Direction Buttons UP/DOWN/LEFT/RIGHT$5Line Selection Switch Line SELECT, 2/4 $1Camera Output Connectors Camera OUT$2Camera Input Connectors Camera $4Line Termination Switch TERM., OFF/ON8Data Port DATA, OUT/IN Installing the WV-PB6164 Data Multiplex Boards InstallationTally Output Setting DIP Switch Setting Alarm Output SettingDummy Black Image Setting Mounting into the Rack Shown below is an example of a basic system connection ConnectionsConnection with the Camera Sites Connections for RS-485 type camera RS-232C Connection with the MonitorsConnection with the PC Data portConnection with External Remote Control Switches Connection with Alarm SensorsSpot and Multiscreen Monitor Monitors and DisplaysConnect the time lapse VCR as shown in the example below Connection with the Time Lapse VCRSetup Procedures Displaying the Setup Menu Setup MenuSetup Menu Programming Setup MenuAlarm Setup Alarm RecallAlarm Schedule Alarm Display on the Monitors Camera Site AlarmVideo Loss Alarm Camera Switching Pulse Loss AlarmDwell Time for Alarm Sequence Alarm Mode on the Multiscreen MonitorAlarm Mode on the Spot Monitor Alarm Recording ModeStill Display Multiscreen Output SetupCamera Title Display Clock DisplayCamera Display Position Setting Sequence ModeSecret View Spot Output Setup Clock Display Record or Multiscreen 2 Output SetupRecord Output Setup Camera Title DisplayRecording Mode Setup Recording Mode Setting DetailsDynamic Recording Multiscreen 2 Output Setup Camera Display Position Sequence ModeSystem Setup Clock SetupClock Display Position Spot Sequence SEQ1 Camera Title SetupSequence Setup Camera Title Display PositionDwell Time Uniform Dwell Time Preset PositionAuto Skip Image AssignmentMulti Sequence SEQ2, SEQ3 Camera/PlaybackDwell Time Programming Steps 2 to Lock ModeSequence Timing Multiscreen Monitor Sequence Timing Spot MonitorCable Compensation/VD2/Data Alarm Terminal SetupCommunication Port Setup Playback ModeData Mode RS-232C ModeDaisy Mode VCR Input SelectUnit Address Password Registration PasswordOther Setup Menus Camera DownloadCamera Upload All Reset Operating Procedures Single Spot Live Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Sequence LiveFreezing Single Spot Live Selecting the Multiscreen MonitorControlling the Camera Images Single Spot LiveZooming Single Spot Live Multiscreen Spot LiveFreezing Multiscreen Spot Live Single or Multi Sequence Live Controlling the Playback ImagesFreezing Single Spot Playback Single Spot PlaybackSingle or Multi Sequence Playback Zooming Single Spot PlaybackMultiscreen Spot Playback Freezing Multiscreen Spot PlaybackMultiscreen Spot Live Images with a Playback Image Displaying the Camera and Playback ImagesFreezing Multiscreen Spot Live Images with a Playback Image Lens Control Controlling Camera Site AccessoriesCamera Control Function Camera SelectionPan/Tilt Control Auto Panning Pan/Tilt Control Preset OperationCamera Setup Pan/Tilt Control Home PositionSimplified preset position setting Alarm Control Function Alarm InputAlarm Operation Spot Output Multiscreen OutputExample of Using Multiscreen 2 Monitor Alarm ResetReset Spot Alarm SuspensionCamera Switching Pulse Loss Display Other FunctionRecording on the Time Lapse VCR Operating Procedures with WV-CU550C Major Operating Controls and Their Functions System Controller WV-CU550C5Preset Position Button PRE-POSI Busy Indicator BusySet Up button SET UP D Time Lapse Mode Buttons T/L MODE, D C@6Mode Selection switch Mode @2Alarm Reset button Reset@4Termination switch TERM., ON/OFF @5Controller Unit Number switch Controller Unit noInstallations Modifying the Front PanelConnection with the WV-CU550C System Controller WJ-FS616C WV-CU550C Function Setup Menu Operations with WV-CU550CControlling the Video Input and Monitors Function Operations with WV-CU550CCamera Control Function RES A.RES Auxiliary Control Alarm Control FunctionSystem Expansion Application Operating ProcedureConnections Other ApplicationsFor Main Site For Local SiteCommunication Protocol Transmission CommandResponse Command AppendixTransmission Response Parameter Ascii Command Ascii Command TableTable below 19 kinds None QOPResponse Command Ascii Main Unit Information Standard Accessories SpecificationsPanasonic Canada Inc