Panasonic WJ-FS616C manual Connections for RS-485 type camera

Page 18

Connections for RS-485 type camera

There are two options to connect the camera with the multiplexer, depending on the distance between them. For data multiplexed type cameras, a maximum dis- tance of 900 meters (3 000 ft) is the limit for using coax- ial cable such as RG-59/U, BELDEN 9259 or equivalent. If more distance is required, use cameras and multi- plexer with RS-485 communication feature. This will lower signal loss and extend the distance as video sig- nal and data are transmitted separately.

Note that you need to set up the communication port as described on page 42 when using the RS-485 feature. Note: Recommended for RS-485 communication is

shielded, two-wire, twisted pair, low impedance cable, AWG#22 or thicker.

(1)Connect with a RS-485 camera in “Home Run” wiring as shown below, then set the LINE SELECT switch to “2” or “4”.

WV-RM70 and others

 

ON

 

OFF

TERM

 

 

 

 

 

DATA

 

 

 

 

T(A)

T(B)

 

R(A) R(B)

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

LINE

 

RS485

 

TERM.

SELECT

 

 

 

 

OFF

ON

2

4

A

B

G

A B

G

 

 

 

T

 

N

R

N

 

WJ-FS616C

 

D

D

 

 

(A)

OFF ON

 

(B)

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WV-CPR450 and others (For the Termination Switch positions, refer to the instruction manual for the camera.)

 

 

 

 

 

 

LINE

 

RS485

 

 

TERM.

SELECT

 

 

 

OFF

ON

2

4

A B

G A

B

G

 

 

 

T

N

R

N

 

WJ-FS616C

D

D

 

(2) Connect cameras in a Daisy Chain

1.Draw up a plan for connection between the cameras and the input channels of the video multiplexer, and the assignment of unit addresses to cameras.

Cautions:

Check the settings of the camera addresses when using cameras capable of RS-485 communication. Operations from the multiplexer will not work if the cam- era addresses are set improperly.

Do not use addresses other than 1 through 16 for individual cameras (“17” is not allowed).

Do not set a single address for more than one cam- era in an RS-485 chain.

2.Set the LINE SELECT switch of the multiplexer to “2”. Also set the switch of the connected equipment if required.

3.Connect one end of the cable as shown to the RS-485 terminal of the multiplexer, and the other end to the first camera in the chain. Repeat this procedure for all cam- eras to the end of the chain.

4.Set the termination switches of the multiplexer and cam- eras at both ends of the chain to ON position. Termination switches of cameras not at the chain ends must be in OFF position.

Cautions:

Termination is the key to data transmission and reception in the chain. Only the switches at the chain ends must be set to ON, while the other switches are set to OFF.

Response may slow gradually the higher the equip- ment number in the chain.

The switch on a daisy-

 

 

 

 

 

 

 

 

 

chain-connected unit not

The switch on the end

at the extremities must

unit should be in the

be in the OFF position.

ON position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(A)

OFF

ON

 

(A)

OFF

 

ON

 

(B)

 

(B)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

GND

 

 

 

 

 

 

 

WV-CPR450 and others (For the Termination Switch positions, refer to the instruction manual for the corresponding unit.)

 

 

 

 

 

 

LINE

 

 

RS485

 

 

TERM.

SELECT

 

 

 

 

OFF

ON

2

4

Set it to

 

 

 

 

 

 

 

 

 

 

 

 

 

 

position 2

A B

G A

B

G

 

 

 

 

T

N

R

N

 

WJ-FS616C

 

D

D

 

 

18

Image 18
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Features PrefaceDo not drop metallic parts through slots PrecautionsFully charge up the backup battery Do not attempt to disassemble the applianceAlarm Reset Button Reset Power Switch Power ON/OFFLock Indicator Lock Alarm Indicator AlarmSpot Monitor Button Spot Camera Number Buttons Camera Preset Position Number Buttons@2Preset Position Button PRE-POSI Multiscreen Monitor Button Multiscreen@6Direction Buttons UP/DOWN/LEFT/RIGHT #1Setup/Escape Button SET UP/ESC#2Lock Switch Lock OFF/ON Left Left Right Right @7Auto Button Auto$4Line Termination Switch TERM., OFF/ON $1Camera Output Connectors Camera OUT$2Camera Input Connectors Camera $5Line Selection Switch Line SELECT, 2/48Data Port DATA, OUT/IN Installation Installing the WV-PB6164 Data Multiplex BoardsTally Output Setting DIP Switch Setting Alarm Output SettingDummy Black Image Setting Mounting into the Rack Connections Shown below is an example of a basic system connectionConnection with the Camera Sites Connections for RS-485 type camera Data port Connection with the MonitorsConnection with the PC RS-232CConnection with Alarm Sensors Connection with External Remote Control SwitchesMonitors and Displays Spot and Multiscreen MonitorConnection with the Time Lapse VCR Connect the time lapse VCR as shown in the example belowSetup Procedures Setup Menu Displaying the Setup MenuProgramming Setup Menu Setup MenuAlarm Setup Alarm RecallAlarm Schedule Camera Switching Pulse Loss Alarm Camera Site AlarmVideo Loss Alarm Alarm Display on the MonitorsAlarm Recording Mode Alarm Mode on the Multiscreen MonitorAlarm Mode on the Spot Monitor Dwell Time for Alarm SequenceClock Display Multiscreen Output SetupCamera Title Display Still DisplayCamera Display Position Setting Sequence ModeSecret View Spot Output Setup Camera Title Display Record or Multiscreen 2 Output SetupRecord Output Setup Clock DisplayRecording Mode Setup Recording Mode Setting DetailsDynamic Recording Multiscreen 2 Output Setup Sequence Mode Camera Display PositionSystem Setup Clock SetupClock Display Position Camera Title Display Position Camera Title SetupSequence Setup Spot Sequence SEQ1Image Assignment Preset PositionAuto Skip Dwell Time Uniform Dwell TimeMulti Sequence SEQ2, SEQ3 Camera/PlaybackDwell Time Sequence Timing Spot Monitor Lock ModeSequence Timing Multiscreen Monitor Programming Steps 2 toAlarm Terminal Setup Cable Compensation/VD2/DataRS-232C Mode Playback ModeData Mode Communication Port SetupDaisy Mode VCR Input SelectUnit Address Password Password RegistrationOther Setup Menus Camera DownloadCamera Upload All Reset Operating Procedures Single Sequence Live Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Spot LiveSingle Spot Live Selecting the Multiscreen MonitorControlling the Camera Images Freezing Single Spot LiveZooming Single Spot Live Multiscreen Spot LiveFreezing Multiscreen Spot Live Controlling the Playback Images Single or Multi Sequence LiveSingle Spot Playback Freezing Single Spot PlaybackFreezing Multiscreen Spot Playback Zooming Single Spot PlaybackMultiscreen Spot Playback Single or Multi Sequence PlaybackDisplaying the Camera and Playback Images Multiscreen Spot Live Images with a Playback ImageFreezing Multiscreen Spot Live Images with a Playback Image Camera Selection Controlling Camera Site AccessoriesCamera Control Function Lens ControlPan/Tilt Control Home Position Pan/Tilt Control Preset OperationCamera Setup Pan/Tilt Control Auto PanningSimplified preset position setting Alarm Control Function Alarm InputAlarm Operation Multiscreen Output Spot OutputAlarm Reset Example of Using Multiscreen 2 MonitorAlarm Suspension Reset SpotCamera Switching Pulse Loss Display Other FunctionRecording on the Time Lapse VCR Operating Procedures with WV-CU550C System Controller WV-CU550C Major Operating Controls and Their FunctionsTime Lapse Mode Buttons T/L MODE, D C Busy Indicator BusySet Up button SET UP D 5Preset Position Button PRE-POSI@5Controller Unit Number switch Controller Unit no @2Alarm Reset button Reset@4Termination switch TERM., ON/OFF @6Mode Selection switch ModeInstallations Modifying the Front PanelConnection with the WV-CU550C System Controller Setup Menu Operations with WV-CU550C WJ-FS616C WV-CU550C FunctionFunction Operations with WV-CU550C Controlling the Video Input and MonitorsCamera Control Function RES A.RES Alarm Control Function Auxiliary ControlSystem Expansion Other Applications Operating ProcedureConnections ApplicationFor Local Site For Main SiteAppendix Transmission CommandResponse Command Communication ProtocolCommand Table Transmission Response Parameter Ascii Command AsciiQOP Table below 19 kinds NoneResponse Command Ascii Main Unit Information Specifications Standard AccessoriesPanasonic Canada Inc