Panasonic WJ-FS616C manual Cable Compensation/VD2/Data, Alarm Terminal Setup

Page 41

Cable Compensation/VD2/Data

This item lets you select the optimum setting for the cable- loss compensator and whether to supply the VD2 (sync) signal or control data to the camera.

Note: These settings will work only for the input channels that have the multiplex feature with the Data Multiplex Board WV-BP6164 installed. The boards are installed for input channels 1 through 4 at the factory. You can install boards for other channels. For installations, see page 12.

1.Press the [FUNCTION] button while the SYSTEMSETUP menu (1 of 2) is displayed on the monitor screen.

The next page of the menu appears on the screen.

2.Move the cursor to CABLE COMP/VD2/DATA SETUP in the SYSTEM MENU, then press the [HOME/SET] button. The CABLE COMP/VD2/DATA SETUP table shown in the figure appears on the monitor screen.

CABLE COMP/VD2/DATA SETUP 1 OF 2

CAM CABLE VD2 DATA

1CH

S

ON

ON

2CH

S

ON

ON

3CH

S

ON

ON

4CH

S

ON

ON

5CH

S

OFF

OFF

6CH

S

OFF

OFF

7CH

S

OFF

OFF

8CH

S

OFF

OFF

5.Select either ON or OFF in the VD2 column by pressing the - or + button.

Note: Select ON for a camera with VD2 capability, oth- erwise select OFF.

6.Select one of the parameters shown below in the DATA column by pressing the - or + button.

ON: Communicates with the camera site by multiplexed data.

1-16:Communicate with the camera site by RS-485. This number indicates the unit address of the selected camera.

OFF: Disables communication with the camera site.

6.Repeat steps 3 to 6 above to edit other channels.

Press the [FUNCTION] button to display the next page of the table, then press this button again to return to the previous page.

7.After finishing the settings, press the [SET UP/ESC] but- ton to execute the settings and returns to the previous SYSTEM SETUP menu.

Note: Installation of the WV-PB6164 Data Multiplex Boards is required for controlling more than 4 cam- eras.

CABLE COMP/VD2/DATA SETUP 2 OF 2

CAM CABLE VD2 DATA

9CH

S

OFF

OFF

10CH

S

OFF

OFF

11CH

S

OFF

OFF

12CH

S

OFF

OFF

13CH

S

OFF

OFF

14CH

S

OFF

OFF

15CH

S

OFF

OFF

16CH

S

OFF

OFF

3.Move the cursor to the columns you want to edit for the channel by pressing the C, D, A or B button.

4.Select one of the parameters shown below in the CABLE column by pressing the - or + button.

This item lets you select a suitable cable-loss compen- sator corresponding with the cable length.

S:Up to 400 m (1 300 ft)

M:400 m (1 300 ft) to 700 m (2 300 ft)

L:700 m (2 300 ft) to 900 m (3 000 ft)

(Using the RG-59/U, BELDEN 9259 or equivalent cable)

Note: Set CABLE to S if no camera is connected to the channel.

Alarm Terminal Setup

This item lets you designate the alarm input from the ALARM/REMOTE port located on the rear of the multiplexer.

1.Move the cursor to ALM TERMINAL SETUP in the SYS- TEM SETUP menu, then press the [HOME/SET] button. The ALARM TERMINAL SETUP table shown in the fig- ure appears on the monitor screen.

 

ALARM

TERMINAL SETUP

 

NO.

CAM

PRE

NO.

CAM

PRE

1

1CH

 

-

9

9CH

-

2

2CH

-

10

10CH

-

3

3CH

-

11

11CH

-

4

4CH

-

12

12CH

-

5

5CH

-

13

13CH

-

6

6CH

-

14

14CH

-

7

7CH

-

15

15CH

-

8

8CH

-

16

16CH

-

2.Move the cursor to the columns you want to edit for the terminal number by pressing the C, D, A or B button.

3.Select the channel number to be assigned in the CAM column by pressing the - or + button.

Note: Channel numbers can also be input directly with the camera number buttons.

41

Image 41
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Preface FeaturesFully charge up the backup battery PrecautionsDo not drop metallic parts through slots Do not attempt to disassemble the applianceLock Indicator Lock Power Switch Power ON/OFFAlarm Reset Button Reset Alarm Indicator Alarm@2Preset Position Button PRE-POSI Camera Number Buttons Camera Preset Position Number ButtonsSpot Monitor Button Spot Multiscreen Monitor Button Multiscreen#2Lock Switch Lock OFF/ON #1Setup/Escape Button SET UP/ESC@6Direction Buttons UP/DOWN/LEFT/RIGHT Left Left Right Right @7Auto Button Auto$2Camera Input Connectors Camera $1Camera Output Connectors Camera OUT$4Line Termination Switch TERM., OFF/ON $5Line Selection Switch Line SELECT, 2/48Data Port DATA, OUT/IN Installing the WV-PB6164 Data Multiplex Boards InstallationTally Output Setting Dummy Black Image Setting DIP Switch SettingAlarm Output Setting Mounting into the Rack Shown below is an example of a basic system connection ConnectionsConnection with the Camera Sites Connections for RS-485 type camera Connection with the PC Connection with the MonitorsData port RS-232CConnection with External Remote Control Switches Connection with Alarm SensorsSpot and Multiscreen Monitor Monitors and DisplaysConnect the time lapse VCR as shown in the example below Connection with the Time Lapse VCRSetup Procedures Displaying the Setup Menu Setup MenuSetup Menu Programming Setup MenuAlarm Schedule Alarm SetupAlarm Recall Video Loss Alarm Camera Site AlarmCamera Switching Pulse Loss Alarm Alarm Display on the MonitorsAlarm Mode on the Spot Monitor Alarm Mode on the Multiscreen MonitorAlarm Recording Mode Dwell Time for Alarm SequenceCamera Title Display Multiscreen Output SetupClock Display Still DisplaySecret View Camera Display Position SettingSequence Mode Spot Output Setup Record Output Setup Record or Multiscreen 2 Output SetupCamera Title Display Clock DisplayDynamic Recording Recording Mode SetupRecording Mode Setting Details Multiscreen 2 Output Setup Camera Display Position Sequence ModeClock Display Position System SetupClock Setup Sequence Setup Camera Title SetupCamera Title Display Position Spot Sequence SEQ1Auto Skip Preset PositionImage Assignment Dwell Time Uniform Dwell TimeDwell Time Multi Sequence SEQ2, SEQ3Camera/Playback Sequence Timing Multiscreen Monitor Lock ModeSequence Timing Spot Monitor Programming Steps 2 toCable Compensation/VD2/Data Alarm Terminal SetupData Mode Playback ModeRS-232C Mode Communication Port SetupUnit Address Daisy ModeVCR Input Select Password Registration PasswordCamera Upload Other Setup MenusCamera Download All Reset Operating Procedures Selecting the Spot Monitor Controlling the Video Input and MonitorsSingle Sequence Live Single Spot LiveControlling the Camera Images Selecting the Multiscreen MonitorSingle Spot Live Freezing Single Spot LiveFreezing Multiscreen Spot Live Zooming Single Spot LiveMultiscreen Spot Live Single or Multi Sequence Live Controlling the Playback ImagesFreezing Single Spot Playback Single Spot PlaybackMultiscreen Spot Playback Zooming Single Spot PlaybackFreezing Multiscreen Spot Playback Single or Multi Sequence PlaybackMultiscreen Spot Live Images with a Playback Image Displaying the Camera and Playback ImagesFreezing Multiscreen Spot Live Images with a Playback Image Camera Control Function Controlling Camera Site AccessoriesCamera Selection Lens ControlCamera Setup Pan/Tilt Control Preset OperationPan/Tilt Control Home Position Pan/Tilt Control Auto PanningSimplified preset position setting Alarm Operation Alarm Control FunctionAlarm Input Spot Output Multiscreen OutputExample of Using Multiscreen 2 Monitor Alarm ResetReset Spot Alarm SuspensionRecording on the Time Lapse VCR Camera Switching Pulse Loss DisplayOther Function Operating Procedures with WV-CU550C Major Operating Controls and Their Functions System Controller WV-CU550CSet Up button SET UP D Busy Indicator BusyTime Lapse Mode Buttons T/L MODE, D C 5Preset Position Button PRE-POSI@4Termination switch TERM., ON/OFF @2Alarm Reset button Reset@5Controller Unit Number switch Controller Unit no @6Mode Selection switch ModeConnection with the WV-CU550C System Controller InstallationsModifying the Front Panel WJ-FS616C WV-CU550C Function Setup Menu Operations with WV-CU550CControlling the Video Input and Monitors Function Operations with WV-CU550CCamera Control Function RES A.RES Auxiliary Control Alarm Control FunctionSystem Expansion Connections Operating ProcedureOther Applications ApplicationFor Main Site For Local SiteResponse Command Transmission CommandAppendix Communication ProtocolTransmission Response Parameter Ascii Command Ascii Command TableTable below 19 kinds None QOPResponse Command Ascii Main Unit Information Standard Accessories SpecificationsPanasonic Canada Inc