Preset Position
1.Move the cursor to the PRE column you want to edit for the area number by pressing the C, D, A or B button.
2.Select the desired preset position number for the cam- era in the PRE column by pressing the - or + button.
3.Repeat steps 1 and 2 above to assign other area num- bers.
Notes:
•When the STEP parameter in this table is on PLAY, it is not possible to select a preset position in the PRE column.
•It is possible to assign the same camera channel to multiple area numbers within a step.
In this case, make sure to assign the same preset positions in the table.
Programming Steps 2 to 5
1.Press the [FUNCTION] button to display the next page of the table.
2.Program the sequence pattern for steps 2 to 5 accord- ing to the procedure described above.
3.After finishing the settings, press the [SET UP/ESC] but- ton to execute the settings and returns to the previous SYSTEM SETUP menu.
■Sequence Timing (Multiscreen Monitor)
This item lets you select between internal and external con- trol for advancing the sequence on the multiscreen monitor. It also lets you select functions of devices connected to pin 26 of the ALARM/REMOTE port.
One of these functions is input of the time adjustment signal from a VCR, the other enables external sequence advance for multiscreen monitor.
1.Move the cursor to the SEQ
2.Select INT
INT: Advances a sequence by the dwell time that was programmed in the SEQUENCE SETUP menu.
It enables input of the time adjustment signal from a Time Lapse VCR.
EXT: Enables external sequence advance.
The factory default setting is INT
Notes:
•If EXT is selected, time adjustment input from a Time Lapse VCR is disabled.
•If EXT is selected, connect the external sequence switch to pin 26 of the ALARM/REMOTE port.
•The multiplexer accepts the time adjustment signal for 6 minutes, that is, 3 minutes before and 3 min- utes after the exact time (For example, from 9:57:00 through 10:03:00. Time is adjusted to 10:00:00).
■Sequence Timing (Spot Monitor)
This item lets you select between internal and external con- trol for advancing the sequence on the spot monitor.
1.Move the cursor to the SEQ
2.Select either INT or EXT.
INT: Advances a sequence by the dwell time that was programmed in the SEQUENCE SETUP menu.
EXT: Advances a sequence by the input from pin 6 of the ALARM/REMOTE port.
The factory default setting is INT.
■Lock Mode
This item lets you determine which buttons will be locked while the LOCK switch is in ON position.
1.Move the cursor to the LOCK MODE parameter in the SYSTEM SETUP menu.
2.Select either ALL or VCR.
VCR: Locks the VCR Control Buttons.
ALL: Locks all the buttons.
The factory default setting is ALL.
Note: The LOCK indicator only lights when the LOCK switch is in ON position and LOCK MODE is set to ALL.
40