Panasonic WJ-FS616C Sequence Timing Multiscreen Monitor, Sequence Timing Spot Monitor, Lock Mode

Page 40

Preset Position

1.Move the cursor to the PRE column you want to edit for the area number by pressing the C, D, A or B button.

2.Select the desired preset position number for the cam- era in the PRE column by pressing the - or + button.

3.Repeat steps 1 and 2 above to assign other area num- bers.

Notes:

When the STEP parameter in this table is on PLAY, it is not possible to select a preset position in the PRE column.

It is possible to assign the same camera channel to multiple area numbers within a step.

In this case, make sure to assign the same preset positions in the table.

Programming Steps 2 to 5

1.Press the [FUNCTION] button to display the next page of the table.

2.Program the sequence pattern for steps 2 to 5 accord- ing to the procedure described above.

3.After finishing the settings, press the [SET UP/ESC] but- ton to execute the settings and returns to the previous SYSTEM SETUP menu.

Sequence Timing (Multiscreen Monitor)

This item lets you select between internal and external con- trol for advancing the sequence on the multiscreen monitor. It also lets you select functions of devices connected to pin 26 of the ALARM/REMOTE port.

One of these functions is input of the time adjustment signal from a VCR, the other enables external sequence advance for multiscreen monitor.

1.Move the cursor to the SEQ TIMING-MLT parameter in the SYSTEM SETUP menu.

2.Select INT (TIME-ADJ) or EXT.

INT: Advances a sequence by the dwell time that was programmed in the SEQUENCE SETUP menu.

It enables input of the time adjustment signal from a Time Lapse VCR.

EXT: Enables external sequence advance.

The factory default setting is INT (TIME-ADJ).

Notes:

If EXT is selected, time adjustment input from a Time Lapse VCR is disabled.

If EXT is selected, connect the external sequence switch to pin 26 of the ALARM/REMOTE port.

The multiplexer accepts the time adjustment signal for 6 minutes, that is, 3 minutes before and 3 min- utes after the exact time (For example, from 9:57:00 through 10:03:00. Time is adjusted to 10:00:00).

Sequence Timing (Spot Monitor)

This item lets you select between internal and external con- trol for advancing the sequence on the spot monitor.

1.Move the cursor to the SEQ TIMING-SPT parameter in the SYSTEM SETUP menu.

2.Select either INT or EXT.

INT: Advances a sequence by the dwell time that was programmed in the SEQUENCE SETUP menu.

EXT: Advances a sequence by the input from pin 6 of the ALARM/REMOTE port.

The factory default setting is INT.

Lock Mode

This item lets you determine which buttons will be locked while the LOCK switch is in ON position.

1.Move the cursor to the LOCK MODE parameter in the SYSTEM SETUP menu.

2.Select either ALL or VCR.

VCR: Locks the VCR Control Buttons.

ALL: Locks all the buttons.

The factory default setting is ALL.

Note: The LOCK indicator only lights when the LOCK switch is in ON position and LOCK MODE is set to ALL.

40

Image 40
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Features PrefacePrecautions Fully charge up the backup batteryDo not drop metallic parts through slots Do not attempt to disassemble the appliancePower Switch Power ON/OFF Lock Indicator LockAlarm Reset Button Reset Alarm Indicator AlarmCamera Number Buttons Camera Preset Position Number Buttons @2Preset Position Button PRE-POSISpot Monitor Button Spot Multiscreen Monitor Button Multiscreen#1Setup/Escape Button SET UP/ESC #2Lock Switch Lock OFF/ON@6Direction Buttons UP/DOWN/LEFT/RIGHT Left Left Right Right @7Auto Button Auto$1Camera Output Connectors Camera OUT $2Camera Input Connectors Camera$4Line Termination Switch TERM., OFF/ON $5Line Selection Switch Line SELECT, 2/48Data Port DATA, OUT/IN Installation Installing the WV-PB6164 Data Multiplex BoardsTally Output Setting Alarm Output Setting DIP Switch SettingDummy Black Image Setting Mounting into the Rack Connections Shown below is an example of a basic system connectionConnection with the Camera Sites Connections for RS-485 type camera Connection with the Monitors Connection with the PCData port RS-232CConnection with Alarm Sensors Connection with External Remote Control SwitchesMonitors and Displays Spot and Multiscreen MonitorConnection with the Time Lapse VCR Connect the time lapse VCR as shown in the example belowSetup Procedures Setup Menu Displaying the Setup MenuProgramming Setup Menu Setup MenuAlarm Recall Alarm SetupAlarm Schedule Camera Site Alarm Video Loss AlarmCamera Switching Pulse Loss Alarm Alarm Display on the MonitorsAlarm Mode on the Multiscreen Monitor Alarm Mode on the Spot MonitorAlarm Recording Mode Dwell Time for Alarm SequenceMultiscreen Output Setup Camera Title DisplayClock Display Still DisplaySequence Mode Camera Display Position SettingSecret View Spot Output Setup Record or Multiscreen 2 Output Setup Record Output SetupCamera Title Display Clock DisplayRecording Mode Setting Details Recording Mode SetupDynamic Recording Multiscreen 2 Output Setup Sequence Mode Camera Display PositionClock Setup System SetupClock Display Position Camera Title Setup Sequence SetupCamera Title Display Position Spot Sequence SEQ1Preset Position Auto SkipImage Assignment Dwell Time Uniform Dwell TimeCamera/Playback Multi Sequence SEQ2, SEQ3Dwell Time Lock Mode Sequence Timing Multiscreen MonitorSequence Timing Spot Monitor Programming Steps 2 toAlarm Terminal Setup Cable Compensation/VD2/DataPlayback Mode Data ModeRS-232C Mode Communication Port SetupVCR Input Select Daisy ModeUnit Address Password Password RegistrationCamera Download Other Setup MenusCamera Upload All Reset Operating Procedures Controlling the Video Input and Monitors Selecting the Spot MonitorSingle Sequence Live Single Spot LiveSelecting the Multiscreen Monitor Controlling the Camera ImagesSingle Spot Live Freezing Single Spot LiveMultiscreen Spot Live Zooming Single Spot LiveFreezing Multiscreen Spot Live Controlling the Playback Images Single or Multi Sequence LiveSingle Spot Playback Freezing Single Spot PlaybackZooming Single Spot Playback Multiscreen Spot PlaybackFreezing Multiscreen Spot Playback Single or Multi Sequence PlaybackDisplaying the Camera and Playback Images Multiscreen Spot Live Images with a Playback ImageFreezing Multiscreen Spot Live Images with a Playback Image Controlling Camera Site Accessories Camera Control FunctionCamera Selection Lens ControlPan/Tilt Control Preset Operation Camera SetupPan/Tilt Control Home Position Pan/Tilt Control Auto PanningSimplified preset position setting Alarm Input Alarm Control FunctionAlarm Operation Multiscreen Output Spot OutputAlarm Reset Example of Using Multiscreen 2 MonitorAlarm Suspension Reset SpotOther Function Camera Switching Pulse Loss DisplayRecording on the Time Lapse VCR Operating Procedures with WV-CU550C System Controller WV-CU550C Major Operating Controls and Their FunctionsBusy Indicator Busy Set Up button SET UP DTime Lapse Mode Buttons T/L MODE, D C 5Preset Position Button PRE-POSI@2Alarm Reset button Reset @4Termination switch TERM., ON/OFF@5Controller Unit Number switch Controller Unit no @6Mode Selection switch ModeModifying the Front Panel InstallationsConnection with the WV-CU550C System Controller Setup Menu Operations with WV-CU550C WJ-FS616C WV-CU550C FunctionFunction Operations with WV-CU550C Controlling the Video Input and MonitorsCamera Control Function RES A.RES Alarm Control Function Auxiliary ControlSystem Expansion Operating Procedure ConnectionsOther Applications ApplicationFor Local Site For Main SiteTransmission Command Response CommandAppendix Communication ProtocolCommand Table Transmission Response Parameter Ascii Command AsciiQOP Table below 19 kinds NoneResponse Command Ascii Main Unit Information Specifications Standard AccessoriesPanasonic Canada Inc