5.Select the desired waiting time for WAIT TIME by press- ing the - or + button.

This item lets you set the waiting time to retry if there is no response from the connected device.

OFF: Selects no retry.

100 – 1000: Selects a waiting time in milli-seconds.

6.Select a number of data bit, 7 or 8, for DATA BIT by pressing the - or + button.

7.Select the parity check mode for PARITY by pressing the - or + button.

NONE: No parity check

EVEN: Even parity

ODD: Odd parity

8.Select a number of stop bit, 1 or 2, for STOP BIT by pressing the - or + button.

9.Select the flow control mode, ON or OFF, for XON/XOFF by pressing the - or + button. (except RS-232C)

OFF: Disables the flow control.

ON: Enables the flow control.

10.Select FULL or HALF Duplex for FULL/HALF by press- ing the - or + button. (RS-485 only)

11.Repeat the above steps to edit other ports.

12.Press the [SET UP/ESC] button to execute the setting and returns to the previous SYSTEM SETUP menu.

VCR Input Select

This item lets you select the VCR input terminal.

1.Move the cursor to the VCR IN SELECT parameter in the SYSTEM SETUP menu.

2.Select input either VIDEO or S-VIDEO.

VIDEO: Selects input from the VCR VIDEO terminal.

S-VIDEO:Selects input from the VCR S-VIDEO termi- nal.

The factory default setting is VIDEO.

Daisy Mode

This item lets you select whether to have the video signal connected to SPOT IN looped through to the SPOT OUT connector (daisy-chain connection).

1.Move the cursor to the DAISY MODE parameter in the SYSTEM SETUP menu.

2.Select either ON or OFF.

ON: Select this parameter if the video multiplexer is daisy-chained.

OFF: Normal position.

The factory default setting is OFF.

Unit Address

This item lets you assign a unit number for identification when multiple video multiplexers are connected in a sys- tem.

1.Move the cursor to the UNIT ADDR. SET parameter in the SYSTEM SETUP menu.

2.Select a unit number, 1 to 16, by pressing the A or B button.

The factory default setting is 1.

43

Image 43
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Preface FeaturesDo not attempt to disassemble the appliance PrecautionsFully charge up the backup battery Do not drop metallic parts through slotsAlarm Indicator Alarm Power Switch Power ON/OFFLock Indicator Lock Alarm Reset Button ResetMultiscreen Monitor Button Multiscreen Camera Number Buttons Camera Preset Position Number Buttons@2Preset Position Button PRE-POSI Spot Monitor Button SpotLeft Left Right Right @7Auto Button Auto #1Setup/Escape Button SET UP/ESC#2Lock Switch Lock OFF/ON @6Direction Buttons UP/DOWN/LEFT/RIGHT$5Line Selection Switch Line SELECT, 2/4 $1Camera Output Connectors Camera OUT$2Camera Input Connectors Camera $4Line Termination Switch TERM., OFF/ON8Data Port DATA, OUT/IN Installing the WV-PB6164 Data Multiplex Boards InstallationTally Output Setting Alarm Output Setting DIP Switch SettingDummy Black Image Setting Mounting into the Rack Shown below is an example of a basic system connection ConnectionsConnection with the Camera Sites Connections for RS-485 type camera RS-232C Connection with the MonitorsConnection with the PC Data portConnection with External Remote Control Switches Connection with Alarm SensorsSpot and Multiscreen Monitor Monitors and DisplaysConnect the time lapse VCR as shown in the example below Connection with the Time Lapse VCRSetup Procedures Displaying the Setup Menu Setup MenuSetup Menu Programming Setup MenuAlarm Recall Alarm SetupAlarm Schedule Alarm Display on the Monitors Camera Site AlarmVideo Loss Alarm Camera Switching Pulse Loss AlarmDwell Time for Alarm Sequence Alarm Mode on the Multiscreen MonitorAlarm Mode on the Spot Monitor Alarm Recording ModeStill Display Multiscreen Output SetupCamera Title Display Clock DisplaySequence Mode Camera Display Position SettingSecret View Spot Output Setup Clock Display Record or Multiscreen 2 Output SetupRecord Output Setup Camera Title DisplayRecording Mode Setting Details Recording Mode SetupDynamic Recording Multiscreen 2 Output Setup Camera Display Position Sequence ModeClock Setup System SetupClock Display Position Spot Sequence SEQ1 Camera Title SetupSequence Setup Camera Title Display PositionDwell Time Uniform Dwell Time Preset PositionAuto Skip Image AssignmentCamera/Playback Multi Sequence SEQ2, SEQ3Dwell Time Programming Steps 2 to Lock ModeSequence Timing Multiscreen Monitor Sequence Timing Spot MonitorCable Compensation/VD2/Data Alarm Terminal SetupCommunication Port Setup Playback ModeData Mode RS-232C ModeVCR Input Select Daisy ModeUnit Address Password Registration PasswordCamera Download Other Setup MenusCamera Upload All Reset Operating Procedures Single Spot Live Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Sequence LiveFreezing Single Spot Live Selecting the Multiscreen MonitorControlling the Camera Images Single Spot LiveMultiscreen Spot Live Zooming Single Spot LiveFreezing Multiscreen Spot Live Single or Multi Sequence Live Controlling the Playback ImagesFreezing Single Spot Playback Single Spot PlaybackSingle or Multi Sequence Playback Zooming Single Spot PlaybackMultiscreen Spot Playback Freezing Multiscreen Spot PlaybackMultiscreen Spot Live Images with a Playback Image Displaying the Camera and Playback ImagesFreezing Multiscreen Spot Live Images with a Playback Image Lens Control Controlling Camera Site AccessoriesCamera Control Function Camera SelectionPan/Tilt Control Auto Panning Pan/Tilt Control Preset OperationCamera Setup Pan/Tilt Control Home PositionSimplified preset position setting Alarm Input Alarm Control FunctionAlarm Operation Spot Output Multiscreen OutputExample of Using Multiscreen 2 Monitor Alarm ResetReset Spot Alarm SuspensionOther Function Camera Switching Pulse Loss DisplayRecording on the Time Lapse VCR Operating Procedures with WV-CU550C Major Operating Controls and Their Functions System Controller WV-CU550C5Preset Position Button PRE-POSI Busy Indicator BusySet Up button SET UP D Time Lapse Mode Buttons T/L MODE, D C@6Mode Selection switch Mode @2Alarm Reset button Reset@4Termination switch TERM., ON/OFF @5Controller Unit Number switch Controller Unit noModifying the Front Panel InstallationsConnection with the WV-CU550C System Controller WJ-FS616C WV-CU550C Function Setup Menu Operations with WV-CU550CControlling the Video Input and Monitors Function Operations with WV-CU550CCamera Control Function RES A.RES Auxiliary Control Alarm Control FunctionSystem Expansion Application Operating ProcedureConnections Other ApplicationsFor Main Site For Local SiteCommunication Protocol Transmission CommandResponse Command AppendixTransmission Response Parameter Ascii Command Ascii Command TableTable below 19 kinds None QOPResponse Command Ascii Main Unit Information Standard Accessories SpecificationsPanasonic Canada Inc