5.Select the desired waiting time for WAIT TIME by press- ing the - or + button.
This item lets you set the waiting time to retry if there is no response from the connected device.
OFF: Selects no retry.
100 – 1000: Selects a waiting time in
6.Select a number of data bit, 7 or 8, for DATA BIT by pressing the - or + button.
7.Select the parity check mode for PARITY by pressing the - or + button.
NONE: No parity check
EVEN: Even parity
ODD: Odd parity
8.Select a number of stop bit, 1 or 2, for STOP BIT by pressing the - or + button.
9.Select the flow control mode, ON or OFF, for XON/XOFF by pressing the - or + button. (except
OFF: Disables the flow control.
ON: Enables the flow control.
10.Select FULL or HALF Duplex for FULL/HALF by press- ing the - or + button.
11.Repeat the above steps to edit other ports.
12.Press the [SET UP/ESC] button to execute the setting and returns to the previous SYSTEM SETUP menu.
■VCR Input Select
This item lets you select the VCR input terminal.
1.Move the cursor to the VCR IN SELECT parameter in the SYSTEM SETUP menu.
2.Select input either VIDEO or
VIDEO: Selects input from the VCR VIDEO terminal.
The factory default setting is VIDEO.
■Daisy Mode
This item lets you select whether to have the video signal connected to SPOT IN looped through to the SPOT OUT connector
1.Move the cursor to the DAISY MODE parameter in the SYSTEM SETUP menu.
2.Select either ON or OFF.
ON: Select this parameter if the video multiplexer is
OFF: Normal position.
The factory default setting is OFF.
■Unit Address
This item lets you assign a unit number for identification when multiple video multiplexers are connected in a sys- tem.
1.Move the cursor to the UNIT ADDR. SET parameter in the SYSTEM SETUP menu.
2.Select a unit number, 1 to 16, by pressing the A or B button.
The factory default setting is 1.
43