SYSTEM SETUP

The procedure described below let you determine the sys- tem designation and display the system status.

WJ-FS616C SETUP MENU

ALARM SETUP *

MULTI OUTPUT SETUP *

SPOT OUTPUT SETUP *

REC/MULTI2 REC OUTPUT *

SYSTEM SETUP *

CAM DOWNLOAD NO

CAM UPLOAD NO

ALL RESET SELECT *

1.Move the cursor to SYSTEM SETUP in the SETUP MENU and then press the [HOME/SET button.

The SYSTEM SETUP menu as shown in the figure appears on the monitor screen.

SYSTEM SETUP

1 OF 2

CLOCK SETUP

JAN

1.97 0:00

CLOCK POSITION *

 

TITLE SETUP *

 

 

TITLE POSITION *

 

SEQUENCE SETUP SEQ1 *

SEQ TIMING-MLT INT(TIME-ADJ)

SEQ TIMING-SPT INT

 

LOCK MODE

ALL

 

 

 

 

 

SYSTEM SETUP

2 OF 2

CABLE COMP/VD2/DATA SETUP *

ALM TERMINAL SETUP

*

PLAYBACK MODE

FIELD

DATA MODE

CU

 

RS-232C MODE

VCR

 

COM PORT SETUP

*

 

VCR IN SELECT

VIDEO

DAISY MODE

OFF

 

UNIT ADDR.SET

1

 

PASSWORD

OFF

 

 

 

 

2.Press the [FUNCTION] button to display the next page of the menu. Press this button again to return to the pre- vious page of the menu.

Clock Setup

This item lets you set the current time and date.

1.Move the cursor to CLOCK SETUP in the SYSTEM SETUP menu and then press the [HOME/SET] button. The cursor moves to the right editing area.

2.Select the month by pressing the A or B button.

3.Move the cursor to the right by pressing the C or D button, then select the date by pressing the A or B button.

4.Select the last 2 digits for the year and time (military time) as similarly by pressing the C or D button and the A or B button.

5.After completing the setting, press the [SET UP/ESC] button to move the cursor to CLOCK SETUP.

The selected time and date are updated when the [SET UP/ESC] button is pressed.

Clock Display Position

This item lets you select the position where the clock will be displayed on the monitor screen.

1.Move the cursor to CLOCK POSITION in the SYSTEM SETUP menu and then press the [HOME/SET] button. The position setting menu shown in the figure appears on the monitor screen.

DEC11.96 12:00:00

CAMTITLE

2.Move the clock position by pressing the C, D, A or B button.

Note: In the multiscreen display with the multiscreen output or record output, the clock display is shifted one line from the preset position if the camera title and the clock are preset to the same position.

3.Press the [SET UP/ESC] button to execute the selection and return to the previous SYSTEM SETUP menu.

36

Image 36
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Features PrefacePrecautions Fully charge up the backup batteryDo not drop metallic parts through slots Do not attempt to disassemble the appliancePower Switch Power ON/OFF Lock Indicator LockAlarm Reset Button Reset Alarm Indicator AlarmCamera Number Buttons Camera Preset Position Number Buttons @2Preset Position Button PRE-POSISpot Monitor Button Spot Multiscreen Monitor Button Multiscreen#1Setup/Escape Button SET UP/ESC #2Lock Switch Lock OFF/ON@6Direction Buttons UP/DOWN/LEFT/RIGHT Left Left Right Right @7Auto Button Auto$1Camera Output Connectors Camera OUT $2Camera Input Connectors Camera$4Line Termination Switch TERM., OFF/ON $5Line Selection Switch Line SELECT, 2/48Data Port DATA, OUT/IN Installation Installing the WV-PB6164 Data Multiplex BoardsTally Output Setting DIP Switch Setting Alarm Output SettingDummy Black Image Setting Mounting into the Rack Connections Shown below is an example of a basic system connectionConnection with the Camera Sites Connections for RS-485 type camera Connection with the Monitors Connection with the PCData port RS-232CConnection with Alarm Sensors Connection with External Remote Control SwitchesMonitors and Displays Spot and Multiscreen MonitorConnection with the Time Lapse VCR Connect the time lapse VCR as shown in the example belowSetup Procedures Setup Menu Displaying the Setup MenuProgramming Setup Menu Setup MenuAlarm Setup Alarm RecallAlarm Schedule Camera Site Alarm Video Loss AlarmCamera Switching Pulse Loss Alarm Alarm Display on the MonitorsAlarm Mode on the Multiscreen Monitor Alarm Mode on the Spot MonitorAlarm Recording Mode Dwell Time for Alarm SequenceMultiscreen Output Setup Camera Title DisplayClock Display Still DisplayCamera Display Position Setting Sequence ModeSecret View Spot Output Setup Record or Multiscreen 2 Output Setup Record Output SetupCamera Title Display Clock DisplayRecording Mode Setup Recording Mode Setting DetailsDynamic Recording Multiscreen 2 Output Setup Sequence Mode Camera Display PositionSystem Setup Clock SetupClock Display Position Camera Title Setup Sequence SetupCamera Title Display Position Spot Sequence SEQ1Preset Position Auto SkipImage Assignment Dwell Time Uniform Dwell TimeMulti Sequence SEQ2, SEQ3 Camera/PlaybackDwell Time Lock Mode Sequence Timing Multiscreen MonitorSequence Timing Spot Monitor Programming Steps 2 toAlarm Terminal Setup Cable Compensation/VD2/DataPlayback Mode Data ModeRS-232C Mode Communication Port SetupDaisy Mode VCR Input SelectUnit Address Password Password RegistrationOther Setup Menus Camera DownloadCamera Upload All Reset Operating Procedures Controlling the Video Input and Monitors Selecting the Spot MonitorSingle Sequence Live Single Spot LiveSelecting the Multiscreen Monitor Controlling the Camera ImagesSingle Spot Live Freezing Single Spot LiveZooming Single Spot Live Multiscreen Spot LiveFreezing Multiscreen Spot Live Controlling the Playback Images Single or Multi Sequence LiveSingle Spot Playback Freezing Single Spot PlaybackZooming Single Spot Playback Multiscreen Spot PlaybackFreezing Multiscreen Spot Playback Single or Multi Sequence PlaybackDisplaying the Camera and Playback Images Multiscreen Spot Live Images with a Playback ImageFreezing Multiscreen Spot Live Images with a Playback Image Controlling Camera Site Accessories Camera Control FunctionCamera Selection Lens ControlPan/Tilt Control Preset Operation Camera SetupPan/Tilt Control Home Position Pan/Tilt Control Auto PanningSimplified preset position setting Alarm Control Function Alarm InputAlarm Operation Multiscreen Output Spot OutputAlarm Reset Example of Using Multiscreen 2 MonitorAlarm Suspension Reset SpotCamera Switching Pulse Loss Display Other FunctionRecording on the Time Lapse VCR Operating Procedures with WV-CU550C System Controller WV-CU550C Major Operating Controls and Their FunctionsBusy Indicator Busy Set Up button SET UP DTime Lapse Mode Buttons T/L MODE, D C 5Preset Position Button PRE-POSI@2Alarm Reset button Reset @4Termination switch TERM., ON/OFF@5Controller Unit Number switch Controller Unit no @6Mode Selection switch ModeInstallations Modifying the Front PanelConnection with the WV-CU550C System Controller Setup Menu Operations with WV-CU550C WJ-FS616C WV-CU550C FunctionFunction Operations with WV-CU550C Controlling the Video Input and MonitorsCamera Control Function RES A.RES Alarm Control Function Auxiliary ControlSystem Expansion Operating Procedure ConnectionsOther Applications ApplicationFor Local Site For Main SiteTransmission Command Response CommandAppendix Communication ProtocolCommand Table Transmission Response Parameter Ascii Command AsciiQOP Table below 19 kinds NoneResponse Command Ascii Main Unit Information Specifications Standard AccessoriesPanasonic Canada Inc