Panasonic WJ-FS616C Auto Skip, Image Assignment, Preset Position, Dwell Time Uniform Dwell Time

Page 38

2.Select SEQ1 and then press the [HOME/SET] button. The SEQ1 SETUP menu shown in the figure appears on the monitor screen.

SEQ1(SPOT-SEQUENCE)SETUP 1 OF 2

AUTO SKIP OFF

DWELL TIME 2SEC

STEP

CAM PRE TIME

STEP CAM PRE TIME

1

1CH

-

2SEC

9

9CH

-

2SEC

2

2CH

-

2SEC

10

10CH

-

2SEC

3

3CH

-

2SEC

11

11CH

-

2SEC

4

4CH

-

2SEC

12

12CH

-

2SEC

5

5CH

-

2SEC

13

13CH

-

2SEC

6

6CH

-

2SEC

14

14CH

-

2SEC

7

7CH

-

2SEC

15

15CH

-

2SEC

8

8CH

-

2SEC

16

16CH

-

2SEC

Auto Skip

1.Move the cursor to the AUTO SKIP parameter.

2.Select either ON or OFF.

ON: Enables the auto skip function.

OFF: Disables the auto skip function.

The factory default setting is OFF.

Note: The auto skip function is not available when play- ing back videotape images.

Image Assignment

1.Move the cursor to the CAM column you want to edit for the step number by pressing the C, D, A or B button.

2.Select the desired camera or playback channel in the CAM column by pressing the - or + button.

1 - 16: Camera Channel

P1 - P16: Playback Channel

–:Not Assigned

Notes:

Pressing the Camera Number button assigns the camera channel directly.

Any playback steps programmed in a sequence are excluded from display on the spot monitor and mul- tiscreen 2 monitor due to the way the system is designed.

3.Repeat steps 1 and 2 above to assign other steps.

Preset Position

1.Move the cursor to the PRE column you want to edit for the step number by pressing the C, D, A or B button.

2.Select the desired preset position number for the cam- era in the PRE column by pressing the - or + button.

Note: A preset position assigned to a step that has been assigned to a playback channel is invalid.

3.Repeat steps 1 and 2 above to assign other steps.

Dwell Time

Uniform Dwell Time

1.Move the cursor to the DWELL TIME parameter by pressing the C or D button.

2.Select the desired dwell time by pressing the A or B button.

Dwell Time can be selected between 0SEC and 30SEC.

Note: If 0SEC is selected for the dwell time, the spot sequence is not activated.

Individual Dwell Time

1.Move the cursor to the TIME column you want to edit for the step number by pressing the C, D, A or B button.

2.Select the desired dwell by pressing the - or + button.

Steps for which a different dwell time has been selected are marked “–” in the DWELL TIME para- meter. Previous settings made in the DWELL TIME parameter become invalid.

Programming Steps 17 to 32

1.Press the [FUNCTION] button to display the next page of the table.

The table shown in the figure appears on the monitor screen.

SEQ1(SPOT-SEQUENCE)SETUP 2 OF 2

STEP CAM PRE TIME

STEP CAM PRE

TIME

17

-

-

2SEC

25

-

-

2SEC

18

-

-

2SEC

26

-

-

2SEC

19

-

-

2SEC

27

-

-

2SEC

20

-

-

2SEC

28

-

-

2SEC

21

-

-

2SEC

29

-

-

2SEC

22

-

-

2SEC

30

-

-

2SEC

23

-

-

2SEC

31

-

-

2SEC

24

-

-

2SEC

32

-

-

2SEC

2.Program the sequence pattern for steps 17 to 32 as described previously.

3.Press the [FUNCTION] button to display the previous page of the table.

38

Image 38
Contents Operating Instructions Lightning flash with arrowhead symbol Important Safety Instructions Contents Features PrefaceDo not drop metallic parts through slots PrecautionsFully charge up the backup battery Do not attempt to disassemble the applianceAlarm Reset Button Reset Power Switch Power ON/OFFLock Indicator Lock Alarm Indicator AlarmSpot Monitor Button Spot Camera Number Buttons Camera Preset Position Number Buttons@2Preset Position Button PRE-POSI Multiscreen Monitor Button Multiscreen@6Direction Buttons UP/DOWN/LEFT/RIGHT #1Setup/Escape Button SET UP/ESC#2Lock Switch Lock OFF/ON Left Left Right Right @7Auto Button Auto$4Line Termination Switch TERM., OFF/ON $1Camera Output Connectors Camera OUT$2Camera Input Connectors Camera $5Line Selection Switch Line SELECT, 2/48Data Port DATA, OUT/IN Installation Installing the WV-PB6164 Data Multiplex BoardsTally Output Setting Dummy Black Image Setting DIP Switch SettingAlarm Output Setting Mounting into the Rack Connections Shown below is an example of a basic system connectionConnection with the Camera Sites Connections for RS-485 type camera Data port Connection with the MonitorsConnection with the PC RS-232CConnection with Alarm Sensors Connection with External Remote Control SwitchesMonitors and Displays Spot and Multiscreen MonitorConnection with the Time Lapse VCR Connect the time lapse VCR as shown in the example belowSetup Procedures Setup Menu Displaying the Setup MenuProgramming Setup Menu Setup MenuAlarm Schedule Alarm SetupAlarm Recall Camera Switching Pulse Loss Alarm Camera Site AlarmVideo Loss Alarm Alarm Display on the MonitorsAlarm Recording Mode Alarm Mode on the Multiscreen MonitorAlarm Mode on the Spot Monitor Dwell Time for Alarm SequenceClock Display Multiscreen Output SetupCamera Title Display Still DisplaySecret View Camera Display Position SettingSequence Mode Spot Output Setup Camera Title Display Record or Multiscreen 2 Output SetupRecord Output Setup Clock DisplayDynamic Recording Recording Mode SetupRecording Mode Setting Details Multiscreen 2 Output Setup Sequence Mode Camera Display PositionClock Display Position System SetupClock Setup Camera Title Display Position Camera Title SetupSequence Setup Spot Sequence SEQ1Image Assignment Preset PositionAuto Skip Dwell Time Uniform Dwell TimeDwell Time Multi Sequence SEQ2, SEQ3Camera/Playback Sequence Timing Spot Monitor Lock ModeSequence Timing Multiscreen Monitor Programming Steps 2 toAlarm Terminal Setup Cable Compensation/VD2/DataRS-232C Mode Playback ModeData Mode Communication Port SetupUnit Address Daisy ModeVCR Input Select Password Password RegistrationCamera Upload Other Setup MenusCamera Download All Reset Operating Procedures Single Sequence Live Controlling the Video Input and MonitorsSelecting the Spot Monitor Single Spot LiveSingle Spot Live Selecting the Multiscreen MonitorControlling the Camera Images Freezing Single Spot LiveFreezing Multiscreen Spot Live Zooming Single Spot LiveMultiscreen Spot Live Controlling the Playback Images Single or Multi Sequence LiveSingle Spot Playback Freezing Single Spot PlaybackFreezing Multiscreen Spot Playback Zooming Single Spot PlaybackMultiscreen Spot Playback Single or Multi Sequence PlaybackDisplaying the Camera and Playback Images Multiscreen Spot Live Images with a Playback ImageFreezing Multiscreen Spot Live Images with a Playback Image Camera Selection Controlling Camera Site AccessoriesCamera Control Function Lens ControlPan/Tilt Control Home Position Pan/Tilt Control Preset OperationCamera Setup Pan/Tilt Control Auto PanningSimplified preset position setting Alarm Operation Alarm Control FunctionAlarm Input Multiscreen Output Spot OutputAlarm Reset Example of Using Multiscreen 2 MonitorAlarm Suspension Reset SpotRecording on the Time Lapse VCR Camera Switching Pulse Loss DisplayOther Function Operating Procedures with WV-CU550C System Controller WV-CU550C Major Operating Controls and Their FunctionsTime Lapse Mode Buttons T/L MODE, D C Busy Indicator BusySet Up button SET UP D 5Preset Position Button PRE-POSI@5Controller Unit Number switch Controller Unit no @2Alarm Reset button Reset@4Termination switch TERM., ON/OFF @6Mode Selection switch ModeConnection with the WV-CU550C System Controller InstallationsModifying the Front Panel Setup Menu Operations with WV-CU550C WJ-FS616C WV-CU550C FunctionFunction Operations with WV-CU550C Controlling the Video Input and MonitorsCamera Control Function RES A.RES Alarm Control Function Auxiliary ControlSystem Expansion Other Applications Operating ProcedureConnections ApplicationFor Local Site For Main SiteAppendix Transmission CommandResponse Command Communication ProtocolCommand Table Transmission Response Parameter Ascii Command AsciiQOP Table below 19 kinds NoneResponse Command Ascii Main Unit Information Specifications Standard AccessoriesPanasonic Canada Inc