Panasonic WV-CU360C manual Operate indicator Operate, Login indicator Login, LED Display

Page 10

MAJOR OPERATING CONTROLS & THEIR FUNCTIONS

Front View (Template for PS Data)

q w e

r t

y u

i

OPERATE

LOGIN

ALARM

MONITOR

CAMERA

BUSY PROHIBITED

UNIT

 

 

 

 

 

System Controller WV-CU360C

!8

!9

 

 

PROGRAM

 

 

 

SETUP

CAM SETUP

 

IRIS

 

 

 

@0

 

 

 

CLOSE

OPEN

SHIFT

FUNCTION

CAM FUNCTION

 

 

@5

 

IRIS RESET

 

 

 

 

ALM RESET

ALM SUSPEND

AUTO

UNIT A

FOCUS

 

@6

NEAR

FAR

 

 

 

ALM RECALL

 

B/W

 

 

UNIT

AUTO FOCUS

@7

VCR CAM

MULTI SCREEN SELECT

DEF

 

 

 

L

@8

 

 

AUX 2

 

 

UNIT B

ZOOM

@9

 

 

 

 

WIDE

TELE

STILL

EL-ZOOM

WIPER

 

 

 

 

 

 

#0

+

AUX 1

 

 

 

 

#1

 

 

 

 

SEQ PAUSE

SEQUENCE

PATROL PLAY

MON

CAM

HOME/PRESET

 

 

 

#2

SLOW

PATROL

PATROL

ESC LOGOUT SET

PROGRAM

 

STOP

LEARN

 

PRESET

@4@2

UP

R

DOWN

@3 @1!7 !6!5!4!3!2!1!0o

qOperate indicator (OPERATE)

Is lit while power is supplied to the System Controller.

wLogin indicator (LOGIN)

Lights up when communication is established with PS Data compatible system units.

eAlarm indicator (ALARM)

yBusy indicator (BUSY)

Lights up when you attempt to control a system unit or camera that is already used by a higher priority opera- tor, or when a higher priority operator selects the cam- era or system unit you are currently operating.

Operations from the System Controller are disabled until this indicator goes off.

Blinks when an alarm is activated.

Blinking changes to steady light when the alarm is auto- matically reset.

To turn the indicator off, press the Alarm Reset button.

rMonitor/Unit indicator ( MONITOR/ UNIT)

When this indicator lights up, the monitor number is dis- played. When it goes off, the unit address is displayed.

tLED Display

LED display allowing you to confirm the monitor or unit number and the number of the currently controlled camera.

It also displays numeric input, error status, etc.

The monitor or unit number is displayed when initial communication is established.

uProhibited indicator (PROHIBITED)

Lights up when an attempt is made to access a function that is prohibited to the operator level.

iJoystick Controller (UP/DOWN/L/R)

Used to manually operate the pan/tilt head, or move the cursor in the setup menu on the active monitor screen. The joystick can also be moved in 8 directions.

Holding down the joystick in the desired position will keep the cursor moving continuously in the setup menu. (See page 17.)

UP: Upward

DOWN: Downward

L:Left

R:Right

10

Image 10
Contents Operating Instructions 360CEnglish Version Important Safety Instructions Contents Handle the appliance with care Do not use any AC adapter other than the one suppliedData Ports Data Controller Number Switch Controller NoMode Selection Switches Mode DC 9 V Input Jack DC 9V Installations Template MountingRear Panel Switch Setting Summary WJ-FS616CPanasonic Security Data PSData Systems Alarm indicator Alarm Busy indicator Busy Operate indicator OperateLogin indicator Login Monitor/Unit indicator MONITOR/ Unit9Setup/Function button SETUP/FUNCTION 4Home/Preset/Programme Preset button8Programme/Camera Setup/Camera Function button Iris buttons IRIS, CLOSE/OPEN@2Defroster/Auxiliary 2 button DEF/AUX @5Alarm Suspend button ALM Suspend@6Alarm Reset/Alarm Recall button ALM RESET/ALM @3Wiper/Auxiliary 1 button WIPER/AUXSystem Connections Installations PSDataConnection Example Data Port Connection PS Data Internal DiagramBasic Connection DIP Switch Setting PS Data Daisy Chain ConnectionController Number Setting PS Data Mode Switch Setting for System ExamplePrior to Setup Controller Setup Procedures PSDataButtons and Controls used for Setup Setup Menus Parity Administrator AuthorizationBaud Rate Wait TimeUser Password Certification User PasswordAdministrator Password Unit a button AssignmentUnit Connection Test Camera CleaningAvailable camera numbers Operating Procedures PSData Basic Operating FlowLog Login/LogoutLog Out Selecting with Unit Number System Unit SelectionSelecting with Unit A/UNIT B Button Monitor Selection Camera SelectionPan/Tilt Control Home/Preset PositionCamera Control Lens ControlCombination Camera Shortcuts IrisData Multiplex Unit Control Housing/AUX ControlSetting Camera SelectionStill Picture Video Multiplexer ControlMultiscreen Selection Electronic ZoomViewing Playback Sequence ControlDigital Disk Recorder Control WJ-HD100 ShortcutsWJ-HD500A Shortcuts Alarm Log 1 line Down Playback of Selected Alarm Show/Hide Alarm LogAlarm Log 1 line Up Alarm LogAlarm Recall Alarm OperationAlarm Reset Press the ALM RESET/ALM Recall buttonCamera Setup Remote Setup of Units & CamerasSystem Unit Setup Camera Patrol Learning ProgramCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C 0Home/Decrement button Home 8Alarm Reset button ALM Reset@1Alarm Suspend button ALM Suspend 1Auto Focus button Auto Focus@6Still button Still @5Preset Position button PRE Posi@8Set Up button SET UP ON/OFF @7Camera Set buttons Camera SET ON/OFFInstallations For WJ-FS616/FS616C WJ-FS616CDIP Switch Setting For Multiplexer Data Port Connection For MultiplexerUnit Version Controller Number SettingSwitch Setting Procedures WJ-FS616Setup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup Operating Procedures For WJ-FS616/FS616C System AUX ControlAlarm Suspension VTR VCR ControlGeneral Setup Shortcut for Preset Position SetupFor WJ-SX350 Matrix Switcher System Front View Template for WJ-SX350 Log-in indicator LoginLED Display Monitor Camera Iris buttons Iris CLOSE/OPEN 3Preset Position button Preset POSI/CAM Posi@0Alarm Acknowledgment and Reset button ACK/RESET Focus buttons Focus NEAR/FAR#1Set Up button SET UP @3All Alarms Reset button ALL Reset@6Alarm Recall button Recall @1@2Backward/Forward Sequence button SEQ BACK/FWDInstallations For WJ-SX350 Example below shows a typical system connectionDIP Switch Setting For WJ-SX350 Data Port Connection For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Lens Control Auto Focus Operation Operating Procedures For WJ-SX350Login & Logout Pan/Tilt Control Camera Position OperationAuxiliary Control Camera Housing ControlPan/Tilt Control Auto/Random Panning Wiper controlSystem Status Display For System WJ-SX850 Matrix Switcher System Alarm indicator Alarm Front View Template for System 850 Matrix SwitcherLink indicator Link Camera indicator Camera Monitor indicator Monitor9Alarm button ALARM, Disarm indicator Disarm 3Programme Preset button Program Preset4Call Preset button Call Preset @0Alarm Acknowledge button ACK@3Previous button Prev @1Alarm Reset button Reset@2Group Preset button Group Preset @4Next button NextPage Installations For System Sensors System Matrix SwitcherData Port Connection TX B TX a RX B RX aDIP Switch Setting Setup Procedures For System Setup Procedures Operating Procedures For System Turn on the power switches of all system componentsAppendix Specifications ControllerALL Reset Panasonic Canada Inc