Panasonic WV-CU360C manual Handle the appliance with care

Page 5

PREFACE

The System Controller WV-CU360C is designed for setup and operation of cameras and other system units installed in a surveillance system.

The controller is compatible with the Panasonic Security Data (PS Data) protocol by default, but DIP switches are provided to select the conventional communication protocol used with the Video Multiplexer WJ-FS616C, Matrix Switcher WJ-SX350 or WJ-SX850. Exchangeable templates

are supplied to adapt the names printed on the buttons to the functions of the unit you wish to control.

You can operate a whole system from the controller, for example, by selecting cameras and monitors, watching monitor screens and indicators, and controlling pan/tilt, lens and other camera functions.

FEATURES

Main features

In a PS Data or a WJ-FS616 system

• Camera channel selection

• Switching of Live pictures and Playback/Changing the

• Monitor Selection

Multiscreen Picture layout/Electronic Zoom/Sequence

• Alarm (Display/Suspend/Recall/Reset)

• System Unit Selection

• Camera and system unit setup

 

Camera controls

Lens functions: Iris/Focus/Auto Focus/Zoom

Housing: Defroster/Wiper/Auxiliary 1, 2

Pan/Tilt: Slow Pan/Slow Tilt/Auto Pan/Auto Sort/Auto Sequence/Random Pan/Preset/Home/Camera Patrol

PRECAUTIONS

Refer all work related to the installation of this product to qualified service personnel or system installers.

Do not attempt to disassemble the appliance.

To prevent electric shock, do not remove screws or covers.

There are no user-serviceable parts inside. Contact qualified service personnel for maintenance.

Handle the appliance with care.

Do not strike or shake, as this may damage the appli- ance.

Do not expose the appliance to water or moisture, nor try to operate it in wet areas.

Take immediate action if the appliance becomes wet. Turn the power off and refer servicing to qualified ser- vice personnel. Moisture may damage the appliance and cause electric shock.

Do not use strong or abrasive detergents when cleaning the appliance body.

Use a dry cloth to clean the appliance when it is dirty. When the dirt is hard to remove, use a mild detergent and wipe gently.

Do not operate the appliance beyond its specified temperature, humidity or power source ratings.

Do not use in the appliance in an extreme environment where high temperature or high humidity exists.

Use the appliance at temperatures within –10˚C - +50˚C (14˚F - 122˚F) and a humidity below 90 %. The input power source for this appliance is 120 V AC 60 Hz by use of the AC Adapter supplied.

Do not use any AC adapter other than the one supplied.

5

Image 5
Contents 360C Operating Instructions English Version Important Safety Instructions Contents Do not use any AC adapter other than the one supplied Handle the appliance with careMode Selection Switches Mode Controller Number Switch Controller NoData Ports Data DC 9 V Input Jack DC 9VTemplate Mounting InstallationsWJ-FS616C Rear Panel Switch Setting SummaryPanasonic Security Data PSData Systems Login indicator Login Operate indicator OperateAlarm indicator Alarm Busy indicator Busy Monitor/Unit indicator MONITOR/ Unit8Programme/Camera Setup/Camera Function button 4Home/Preset/Programme Preset button9Setup/Function button SETUP/FUNCTION Iris buttons IRIS, CLOSE/OPEN@6Alarm Reset/Alarm Recall button ALM RESET/ALM @5Alarm Suspend button ALM Suspend@2Defroster/Auxiliary 2 button DEF/AUX @3Wiper/Auxiliary 1 button WIPER/AUXConnection Example Installations PSDataSystem Connections Basic Connection Internal DiagramData Port Connection PS Data Daisy Chain Connection DIP Switch Setting PS DataMode Switch Setting for System Example Controller Number Setting PS DataButtons and Controls used for Setup Controller Setup Procedures PSDataPrior to Setup Setup Menus Baud Rate Administrator AuthorizationParity Wait TimeAdministrator Password User PasswordUser Password Certification Unit a button AssignmentAvailable camera numbers Camera CleaningUnit Connection Test Basic Operating Flow Operating Procedures PSDataLog Out Login/LogoutLog Selecting with Unit A/UNIT B Button System Unit SelectionSelecting with Unit Number Camera Selection Monitor SelectionCamera Control Home/Preset PositionPan/Tilt Control Lens ControlIris Combination Camera ShortcutsSetting Housing/AUX ControlData Multiplex Unit Control Camera SelectionMultiscreen Selection Video Multiplexer ControlStill Picture Electronic ZoomSequence Control Viewing PlaybackWJ-HD100 Shortcuts Digital Disk Recorder ControlWJ-HD500A Shortcuts Alarm Log 1 line Up Show/Hide Alarm LogAlarm Log 1 line Down Playback of Selected Alarm Alarm LogAlarm Reset Alarm OperationAlarm Recall Press the ALM RESET/ALM Recall buttonSystem Unit Setup Remote Setup of Units & CamerasCamera Setup Program Camera Patrol LearningCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C @1Alarm Suspend button ALM Suspend 8Alarm Reset button ALM Reset0Home/Decrement button Home 1Auto Focus button Auto Focus@8Set Up button SET UP ON/OFF @5Preset Position button PRE Posi@6Still button Still @7Camera Set buttons Camera SET ON/OFFWJ-FS616C Installations For WJ-FS616/FS616CData Port Connection For Multiplexer DIP Switch Setting For MultiplexerSwitch Setting Procedures Controller Number SettingUnit Version WJ-FS616Setup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup AUX Control Operating Procedures For WJ-FS616/FS616C SystemVTR VCR Control Alarm SuspensionShortcut for Preset Position Setup General SetupFor WJ-SX350 Matrix Switcher System LED Display Monitor Camera Log-in indicator LoginFront View Template for WJ-SX350 @0Alarm Acknowledgment and Reset button ACK/RESET 3Preset Position button Preset POSI/CAM PosiIris buttons Iris CLOSE/OPEN Focus buttons Focus NEAR/FAR@6Alarm Recall button Recall @3All Alarms Reset button ALL Reset#1Set Up button SET UP @1@2Backward/Forward Sequence button SEQ BACK/FWDExample below shows a typical system connection Installations For WJ-SX350Data Port Connection For WJ-SX350 DIP Switch Setting For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Login & Logout Operating Procedures For WJ-SX350Lens Control Auto Focus Operation Pan/Tilt Control Camera Position OperationPan/Tilt Control Auto/Random Panning Camera Housing ControlAuxiliary Control Wiper controlSystem Status Display For System WJ-SX850 Matrix Switcher System Link indicator Link Camera indicator Camera Front View Template for System 850 Matrix SwitcherAlarm indicator Alarm Monitor indicator Monitor4Call Preset button Call Preset 3Programme Preset button Program Preset9Alarm button ALARM, Disarm indicator Disarm @0Alarm Acknowledge button ACK@2Group Preset button Group Preset @1Alarm Reset button Reset@3Previous button Prev @4Next button NextPage Sensors System Matrix Switcher Installations For SystemTX B TX a RX B RX a Data Port ConnectionDIP Switch Setting Setup Procedures For System Setup Procedures Turn on the power switches of all system components Operating Procedures For SystemAppendix Controller SpecificationsALL Reset Panasonic Canada Inc