MAJOR OPERATING CONTROLS & THEIR FUNCTIONS

Front View (Template for WJ-SX350)

q w e

r

t y

OPERATE

LOGIN

ALARM

MONITOR

 

 

 

 

 

 

CAMERA

 

BUSY PROHIBITED

 

 

 

 

System Controller WV-CU360C

 

 

 

 

For Matrix Switcher

CAMERA SITE CONTROL

ALT

PAUSE

FUNCTION

 

IRIS

!7!8!9

 

 

CLOSE

OPEN

 

 

 

 

IRIS RESET

ACK/RESET

BACK

FWD

AUX

FOCUS

@0@1@2

SEQ

 

NEAR

FAR

 

 

 

-1 CAM

+1 CAM

 

 

 

 

 

AUTO FOCUS

ALL RESET

 

DEC

 

INC

 

 

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

@3@4@5

 

 

 

PAN

ZOOM

 

 

 

 

RECALL BACK

FWD

 

 

TELE

WIDE

 

 

 

 

@6@7@8

HISTORY

 

 

 

 

 

 

 

 

 

STATUS

 

MON

CAM

PRESET

 

 

POSI

 

@9#0#1

 

 

 

 

 

CAM

SET UP

ESC

SET

CAM

 

MENU

 

 

POSI

 

 

 

 

 

UP

R

DOWN

!6 !5 !4 !3!2!1 !0oi u

qOperate indicator (OPERATE)

Is lit while power is supplied to the System Controller.

wLog-in indicator (LOGIN)

Lights up when login has been successfully finished.

eAlarm indicator (ALARM)

tBusy indicator (BUSY)

Blinks or lights up when you attempt to control a certain monitor (or a camera) that is already used by a higher priority operator, or when the higher priority operator chooses the camera or monitor you are currently oper- ating.

Blinks when an alarm condition exists.

It changes to steady light when the alarm is reset auto- matically.

To turn off the indicator, press the ACK/RESET or ALL RESET button.

rLED Display (MONITOR CAMERA)

Displays the number of monitors and cameras currently controlled.

Blinking:

Monitor Busy

Steady light:

Camera Busy

yProhibited indicator (PROHIBITED)

Lights up for two seconds when an invalid operator number or password is used to log in. The indicator also blinks when an attempt is made to access a func- tion that is prohibited for the given operator level.

54

Image 52
Contents Operating Instructions 360CEnglish Version Important Safety Instructions Contents Handle the appliance with care Do not use any AC adapter other than the one suppliedController Number Switch Controller No Mode Selection Switches ModeData Ports Data DC 9 V Input Jack DC 9VInstallations Template MountingRear Panel Switch Setting Summary WJ-FS616CPanasonic Security Data PSData Systems Operate indicator Operate Login indicator LoginAlarm indicator Alarm Busy indicator Busy Monitor/Unit indicator MONITOR/ Unit4Home/Preset/Programme Preset button 8Programme/Camera Setup/Camera Function button9Setup/Function button SETUP/FUNCTION Iris buttons IRIS, CLOSE/OPEN@5Alarm Suspend button ALM Suspend @6Alarm Reset/Alarm Recall button ALM RESET/ALM@2Defroster/Auxiliary 2 button DEF/AUX @3Wiper/Auxiliary 1 button WIPER/AUXSystem Connections Installations PSDataConnection Example Data Port Connection PS Data Internal DiagramBasic Connection DIP Switch Setting PS Data Daisy Chain ConnectionController Number Setting PS Data Mode Switch Setting for System ExamplePrior to Setup Controller Setup Procedures PSDataButtons and Controls used for Setup Setup Menus Administrator Authorization Baud RateParity Wait TimeUser Password Administrator PasswordUser Password Certification Unit a button AssignmentUnit Connection Test Camera CleaningAvailable camera numbers Operating Procedures PSData Basic Operating FlowLog Login/LogoutLog Out Selecting with Unit Number System Unit SelectionSelecting with Unit A/UNIT B Button Monitor Selection Camera SelectionHome/Preset Position Camera ControlPan/Tilt Control Lens ControlCombination Camera Shortcuts IrisHousing/AUX Control SettingData Multiplex Unit Control Camera SelectionVideo Multiplexer Control Multiscreen SelectionStill Picture Electronic ZoomViewing Playback Sequence ControlDigital Disk Recorder Control WJ-HD100 ShortcutsWJ-HD500A Shortcuts Show/Hide Alarm Log Alarm Log 1 line UpAlarm Log 1 line Down Playback of Selected Alarm Alarm LogAlarm Operation Alarm ResetAlarm Recall Press the ALM RESET/ALM Recall buttonCamera Setup Remote Setup of Units & CamerasSystem Unit Setup Camera Patrol Learning ProgramCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C 8Alarm Reset button ALM Reset @1Alarm Suspend button ALM Suspend0Home/Decrement button Home 1Auto Focus button Auto Focus@5Preset Position button PRE Posi @8Set Up button SET UP ON/OFF@6Still button Still @7Camera Set buttons Camera SET ON/OFFInstallations For WJ-FS616/FS616C WJ-FS616CDIP Switch Setting For Multiplexer Data Port Connection For MultiplexerController Number Setting Switch Setting ProceduresUnit Version WJ-FS616Setup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup Operating Procedures For WJ-FS616/FS616C System AUX Control Alarm Suspension VTR VCR ControlGeneral Setup Shortcut for Preset Position SetupFor WJ-SX350 Matrix Switcher System Front View Template for WJ-SX350 Log-in indicator LoginLED Display Monitor Camera 3Preset Position button Preset POSI/CAM Posi @0Alarm Acknowledgment and Reset button ACK/RESETIris buttons Iris CLOSE/OPEN Focus buttons Focus NEAR/FAR@3All Alarms Reset button ALL Reset @6Alarm Recall button Recall#1Set Up button SET UP @1@2Backward/Forward Sequence button SEQ BACK/FWDInstallations For WJ-SX350 Example below shows a typical system connectionDIP Switch Setting For WJ-SX350 Data Port Connection For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Operating Procedures For WJ-SX350 Login & LogoutLens Control Auto Focus Operation Pan/Tilt Control Camera Position OperationCamera Housing Control Pan/Tilt Control Auto/Random PanningAuxiliary Control Wiper controlSystem Status Display For System WJ-SX850 Matrix Switcher System Front View Template for System 850 Matrix Switcher Link indicator Link Camera indicator CameraAlarm indicator Alarm Monitor indicator Monitor3Programme Preset button Program Preset 4Call Preset button Call Preset9Alarm button ALARM, Disarm indicator Disarm @0Alarm Acknowledge button ACK@1Alarm Reset button Reset @2Group Preset button Group Preset@3Previous button Prev @4Next button NextPage Installations For System Sensors System Matrix SwitcherData Port Connection TX B TX a RX B RX aDIP Switch Setting Setup Procedures For System Setup Procedures Operating Procedures For System Turn on the power switches of all system componentsAppendix Specifications ControllerALL Reset Panasonic Canada Inc