Panasonic WV-CU360C manual Installations PSData, System Connections, Connection Example

Page 13

INSTALLATIONS (PSData)

CAUTION

The installation should be made by qualified service personnel or system installers according to the following instructions.

System Connections

Connection Example

Example 1 shows 8 cameras connected to 2 Data Multiplex Units (WJ-MP204C), to a Video Multiplexer (e.g., WJ-FS316) and a Digital Disk Recorder (e.g., WJ-HD100). The WV-CU360C controls these system units through RS-485 communication while pictures are viewed on the monitors.

Camera No. 5

Camera No. 6

Camera No. 7

Camera No. 8

Camera No. 4

Camera No. 1

 

Camera No. 2

 

Camera No. 3

VS/VD INPUT

VS/VD OUTPUT

Unit Address 2

Unit Address 1

WJ-MP204C

IN

4

3

2

1

IN

IN

OUT

4

3

2

1

OUT

OUT

 

 

CAMERA

 

SPOT

 

VS/VD

ALARM / REMOTE

IN

4

3

2

1

IN

IN ALARM / REMOTE

 

SD

RD

 

 

 

 

 

 

 

T

R

 

G B

A B

A

SIGNAL GND

 

 

 

 

 

G B A B

A

SIGNAL GND

 

 

 

OUT

4

3

2

1

OUT

OUT

 

 

RS485

DATA

MODE

 

CAMERA

 

SPOT

VS/VD

RS485

DATA

MODE

WJ-MP204C

MODE

MODE

4-Line

Termination ON

 

4-Line

 

Termination OFF

VD OUT

Panasonic Security

Data mode

 

Panasonic Security Data mode

WJ-FS316

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

IN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIGNAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ALARM/REMOTE

DATA

CAMERA

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SW IN

 

OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

 

 

 

 

 

 

 

 

 

 

 

VIDEO

 

 

 

 

 

 

MULTI

 

SPOT OUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PLAY IN REC OUT SCREEN OUT

 

 

 

 

 

Unit Address 3

 

 

 

 

 

PLAY

 

 

 

PLAY IN

 

 

 

VIDEO IN

 

 

 

REC OUT

 

 

 

 

REC)(EXT CLICK-JOG LEFT-JOG

RIGHT-JOG G SEARCHALARM STEP

REW/FF STOP/SETUP PLAY REC G OUT IN OUTPLAY OUTREC OUTOFFAUTO

OUTENDDISK OUT IN

G RECALL OUT OUTRECOVER INRESET IN

POWER

IN

 

IN

 

 

 

 

ON

 

WJ-HD100 OUT

 

 

 

 

 

 

SIGNAL GND

 

OUT

 

 

 

 

OFF

 

AUDIO

CAMERA

VIDEO MONITOR OUT RS-232C

DATA MODE

REMOTE

TIME

SERIES

ALARM

 

SW OUT

 

 

(PLAY)

 

 

ADJUST

RECORD

 

 

 

 

Branch

Unit Address 4

 

 

 

 

 

Cable

 

 

 

 

 

 

Monitor No. 1

Monitor No. 2

Up to four WV-CU360C can be used in a system.

RS-485 Cable

6-conductor Modular Cable (supplied)

1

 

 

6

 

 

CONTROLLER No. MODE

DATA

DC 9V IN

 

 

 

 

 

 

 

 

 

 

 

 

 

Keep in OFF position

 

 

 

 

 

 

 

 

 

 

 

 

 

Termination ON

Controller No. 1

 

 

 

 

 

 

 

 

 

 

Set to OFF position

 

 

 

 

 

 

 

 

 

 

(for operator mode)

9

0

1

 

 

 

 

 

 

 

 

 

 

Keep in OFF position

 

 

 

 

 

 

 

 

 

 

8

 

2

 

 

 

 

 

 

 

 

 

 

 

7

 

3

 

 

 

 

 

 

 

 

 

 

 

6

5

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROLLER No.

 

 

 

 

 

 

 

 

 

 

 

 

Refer to DIP switch setting on page 15

 

 

 

 

Video Signal

RS-485 Signal

(Panasonic Security

Data Mode)

13

Image 13
Contents 360C Operating InstructionsEnglish Version Important Safety Instructions Contents Do not use any AC adapter other than the one supplied Handle the appliance with careMode Selection Switches Mode Controller Number Switch Controller NoData Ports Data DC 9 V Input Jack DC 9VTemplate Mounting InstallationsWJ-FS616C Rear Panel Switch Setting SummaryPanasonic Security Data PSData Systems Login indicator Login Operate indicator OperateAlarm indicator Alarm Busy indicator Busy Monitor/Unit indicator MONITOR/ Unit8Programme/Camera Setup/Camera Function button 4Home/Preset/Programme Preset button9Setup/Function button SETUP/FUNCTION Iris buttons IRIS, CLOSE/OPEN@6Alarm Reset/Alarm Recall button ALM RESET/ALM @5Alarm Suspend button ALM Suspend@2Defroster/Auxiliary 2 button DEF/AUX @3Wiper/Auxiliary 1 button WIPER/AUXSystem Connections Installations PSDataConnection Example Data Port Connection PS Data Internal DiagramBasic Connection Daisy Chain Connection DIP Switch Setting PS DataMode Switch Setting for System Example Controller Number Setting PS DataPrior to Setup Controller Setup Procedures PSDataButtons and Controls used for Setup Setup Menus Baud Rate Administrator AuthorizationParity Wait TimeAdministrator Password User PasswordUser Password Certification Unit a button AssignmentUnit Connection Test Camera CleaningAvailable camera numbers Basic Operating Flow Operating Procedures PSDataLog Login/LogoutLog Out Selecting with Unit Number System Unit SelectionSelecting with Unit A/UNIT B Button Camera Selection Monitor SelectionCamera Control Home/Preset PositionPan/Tilt Control Lens ControlIris Combination Camera ShortcutsSetting Housing/AUX ControlData Multiplex Unit Control Camera SelectionMultiscreen Selection Video Multiplexer ControlStill Picture Electronic ZoomSequence Control Viewing PlaybackWJ-HD100 Shortcuts Digital Disk Recorder ControlWJ-HD500A Shortcuts Alarm Log 1 line Up Show/Hide Alarm LogAlarm Log 1 line Down Playback of Selected Alarm Alarm LogAlarm Reset Alarm OperationAlarm Recall Press the ALM RESET/ALM Recall buttonCamera Setup Remote Setup of Units & CamerasSystem Unit Setup Program Camera Patrol LearningCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C @1Alarm Suspend button ALM Suspend 8Alarm Reset button ALM Reset0Home/Decrement button Home 1Auto Focus button Auto Focus@8Set Up button SET UP ON/OFF @5Preset Position button PRE Posi@6Still button Still @7Camera Set buttons Camera SET ON/OFFWJ-FS616C Installations For WJ-FS616/FS616CData Port Connection For Multiplexer DIP Switch Setting For MultiplexerSwitch Setting Procedures Controller Number SettingUnit Version WJ-FS616Setup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup AUX Control Operating Procedures For WJ-FS616/FS616C SystemVTR VCR Control Alarm SuspensionShortcut for Preset Position Setup General SetupFor WJ-SX350 Matrix Switcher System Front View Template for WJ-SX350 Log-in indicator LoginLED Display Monitor Camera @0Alarm Acknowledgment and Reset button ACK/RESET 3Preset Position button Preset POSI/CAM PosiIris buttons Iris CLOSE/OPEN Focus buttons Focus NEAR/FAR@6Alarm Recall button Recall @3All Alarms Reset button ALL Reset#1Set Up button SET UP @1@2Backward/Forward Sequence button SEQ BACK/FWDExample below shows a typical system connection Installations For WJ-SX350Data Port Connection For WJ-SX350 DIP Switch Setting For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Login & Logout Operating Procedures For WJ-SX350Lens Control Auto Focus Operation Pan/Tilt Control Camera Position OperationPan/Tilt Control Auto/Random Panning Camera Housing ControlAuxiliary Control Wiper controlSystem Status Display For System WJ-SX850 Matrix Switcher System Link indicator Link Camera indicator Camera Front View Template for System 850 Matrix SwitcherAlarm indicator Alarm Monitor indicator Monitor4Call Preset button Call Preset 3Programme Preset button Program Preset9Alarm button ALARM, Disarm indicator Disarm @0Alarm Acknowledge button ACK@2Group Preset button Group Preset @1Alarm Reset button Reset@3Previous button Prev @4Next button NextPage Sensors System Matrix Switcher Installations For SystemTX B TX a RX B RX a Data Port ConnectionDIP Switch Setting Setup Procedures For System Setup Procedures Turn on the power switches of all system components Operating Procedures For SystemAppendix Controller SpecificationsALL Reset Panasonic Canada Inc