●Camera Cleaning
This menu is for specifying the order in which combination cameras connected to the system are cleaned.
The camera cleaning function causes cleaning of the built- in slip rings that conduct electric signals while moving the pan/tilt head. All combination cameras connected to the system are cleaned in the order specified here. Picture viewing is disabled during the cleaning process.
1.Display [CLEAn] and press the CAM/SET button. The LED displays
2.Use the numeric buttons to enter the number of the camera where cleaning is to start.
The default setting is
Available camera numbers: 01-199
3.Press the CAM/SET button to start cleaning.
Two animated digits appear in the left part of the LCD while the digits at right display the number of the cam- era being cleaned.
When cleaning is finished, the number of the last cam- era cleaned is displayed without animation.
4.Press the ESC button to go back to the previous menu.
●Unit Connection Test
This menu is for specifying the order in which data commu- nication between system units is tested prior to operating the system as a whole.
1.Display [UtESt] and press the CAM/SET button. The LED displays
2.Enter the
3.Press the CAM/SET button to start the test.
The digits in the left part of the LCD display the unit number under test while 2 animated digits appear at right.
To stop the test in progress, press the CAM/SET button. When testing is finished, the number of the last unit test- ed is displayed without animation.
4.Press the CAM/SET button. Enter a
You can now confirm the test results of a specific unit. When Off is displayed, check connections, switch set- tings, etc., of the system unit.
5. Press the ESC button to go back to the previous menu.
21