Camera Cleaning

This menu is for specifying the order in which combination cameras connected to the system are cleaned.

The camera cleaning function causes cleaning of the built- in slip rings that conduct electric signals while moving the pan/tilt head. All combination cameras connected to the system are cleaned in the order specified here. Picture viewing is disabled during the cleaning process.

1.Display [CLEAn] and press the CAM/SET button. The LED displays [no-01].

2.Use the numeric buttons to enter the number of the camera where cleaning is to start.

The default setting is no-01.

Available camera numbers: 01-199

3.Press the CAM/SET button to start cleaning.

Two animated digits appear in the left part of the LCD while the digits at right display the number of the cam- era being cleaned.

When cleaning is finished, the number of the last cam- era cleaned is displayed without animation.

4.Press the ESC button to go back to the previous menu.

Unit Connection Test

This menu is for specifying the order in which data commu- nication between system units is tested prior to operating the system as a whole.

1.Display [UtESt] and press the CAM/SET button. The LED displays [01-on] or [01-oF].

2.Enter the 2-digit unit number you wish to start with.

3.Press the CAM/SET button to start the test.

The digits in the left part of the LCD display the unit number under test while 2 animated digits appear at right.

To stop the test in progress, press the CAM/SET button. When testing is finished, the number of the last unit test- ed is displayed without animation.

4.Press the CAM/SET button. Enter a 2-digit number(e.g., 01), then press the CAM/SET button.

You can now confirm the test results of a specific unit. When Off is displayed, check connections, switch set- tings, etc., of the system unit.

01-on:On, unit 01 is connected.

01-oF:Off, unit 01 is disconnected.

5. Press the ESC button to go back to the previous menu.

21

Image 21
Contents 360C Operating InstructionsEnglish Version Important Safety Instructions Contents Do not use any AC adapter other than the one supplied Handle the appliance with careMode Selection Switches Mode Controller Number Switch Controller NoData Ports Data DC 9 V Input Jack DC 9VTemplate Mounting InstallationsWJ-FS616C Rear Panel Switch Setting SummaryPanasonic Security Data PSData Systems Login indicator Login Operate indicator OperateAlarm indicator Alarm Busy indicator Busy Monitor/Unit indicator MONITOR/ Unit8Programme/Camera Setup/Camera Function button 4Home/Preset/Programme Preset button9Setup/Function button SETUP/FUNCTION Iris buttons IRIS, CLOSE/OPEN@6Alarm Reset/Alarm Recall button ALM RESET/ALM @5Alarm Suspend button ALM Suspend@2Defroster/Auxiliary 2 button DEF/AUX @3Wiper/Auxiliary 1 button WIPER/AUXInstallations PSData System ConnectionsConnection Example Internal Diagram Data Port Connection PS DataBasic Connection Daisy Chain Connection DIP Switch Setting PS DataMode Switch Setting for System Example Controller Number Setting PS DataController Setup Procedures PSData Prior to SetupButtons and Controls used for Setup Setup Menus Baud Rate Administrator AuthorizationParity Wait TimeAdministrator Password User PasswordUser Password Certification Unit a button AssignmentCamera Cleaning Unit Connection TestAvailable camera numbers Basic Operating Flow Operating Procedures PSDataLogin/Logout LogLog Out System Unit Selection Selecting with Unit NumberSelecting with Unit A/UNIT B Button Camera Selection Monitor SelectionCamera Control Home/Preset PositionPan/Tilt Control Lens ControlIris Combination Camera ShortcutsSetting Housing/AUX ControlData Multiplex Unit Control Camera SelectionMultiscreen Selection Video Multiplexer ControlStill Picture Electronic ZoomSequence Control Viewing PlaybackWJ-HD100 Shortcuts Digital Disk Recorder ControlWJ-HD500A Shortcuts Alarm Log 1 line Up Show/Hide Alarm LogAlarm Log 1 line Down Playback of Selected Alarm Alarm LogAlarm Reset Alarm OperationAlarm Recall Press the ALM RESET/ALM Recall buttonRemote Setup of Units & Cameras Camera SetupSystem Unit Setup Program Camera Patrol LearningCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C @1Alarm Suspend button ALM Suspend 8Alarm Reset button ALM Reset0Home/Decrement button Home 1Auto Focus button Auto Focus@8Set Up button SET UP ON/OFF @5Preset Position button PRE Posi@6Still button Still @7Camera Set buttons Camera SET ON/OFFWJ-FS616C Installations For WJ-FS616/FS616CData Port Connection For Multiplexer DIP Switch Setting For MultiplexerSwitch Setting Procedures Controller Number SettingUnit Version WJ-FS616Setup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup AUX Control Operating Procedures For WJ-FS616/FS616C SystemVTR VCR Control Alarm SuspensionShortcut for Preset Position Setup General SetupFor WJ-SX350 Matrix Switcher System Log-in indicator Login Front View Template for WJ-SX350LED Display Monitor Camera @0Alarm Acknowledgment and Reset button ACK/RESET 3Preset Position button Preset POSI/CAM PosiIris buttons Iris CLOSE/OPEN Focus buttons Focus NEAR/FAR@6Alarm Recall button Recall @3All Alarms Reset button ALL Reset#1Set Up button SET UP @1@2Backward/Forward Sequence button SEQ BACK/FWDExample below shows a typical system connection Installations For WJ-SX350Data Port Connection For WJ-SX350 DIP Switch Setting For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Login & Logout Operating Procedures For WJ-SX350Lens Control Auto Focus Operation Pan/Tilt Control Camera Position OperationPan/Tilt Control Auto/Random Panning Camera Housing ControlAuxiliary Control Wiper controlSystem Status Display For System WJ-SX850 Matrix Switcher System Link indicator Link Camera indicator Camera Front View Template for System 850 Matrix SwitcherAlarm indicator Alarm Monitor indicator Monitor4Call Preset button Call Preset 3Programme Preset button Program Preset9Alarm button ALARM, Disarm indicator Disarm @0Alarm Acknowledge button ACK@2Group Preset button Group Preset @1Alarm Reset button Reset@3Previous button Prev @4Next button NextPage Sensors System Matrix Switcher Installations For SystemTX B TX a RX B RX a Data Port ConnectionDIP Switch Setting Setup Procedures For System Setup Procedures Turn on the power switches of all system components Operating Procedures For SystemAppendix Controller SpecificationsALL Reset Panasonic Canada Inc