Set up the baud rate and parity check mode for the controller while observing the LED on the front panel.

Menu

 

Setup Menus

 

 

Parameter Selection (default*)

LED Display

Reading

Function

 

Selection

 

 

 

 

 

 

 

 

 

 

 

CAM

 

 

 

Setup

Initial

 

LED prompts you to enter pass-

 

 

Display

 

word

 

 

 

SET

 

 

 

 

 

No

 

 

 

 

Enter a 5-digit password,

 

 

 

 

 

 

 

Administrator

Authorization

 

press CAM (12345*)

OK

 

Password

 

 

blinking

Prompt

 

 

 

 

 

 

 

SET

 

 

 

 

 

 

 

 

 

Press

 

Move Joystick

 

Baud Rate

twice

(1) 2 400 (2) 4 800 (3) 9 600*

Speed

 

UP and down

 

(bps)

CAM

(4) 19 200

to select

 

 

 

 

 

 

 

L

R

 

 

SET

 

 

 

 

 

 

DOWN

 

 

 

MON

 

UP

 

Parity

Parity Check

 

(1) None* (2) Even

 

 

 

L

R

 

 

 

 

 

 

 

 

ESC

 

Administrator Authorization

1.Press the CAM/SET button while [SEtUP] is displayed. The [- - - - -] prompt appears.

2.Enter a password using the numeric buttons, then press the CAM/SET button.

The default setting is [12345].

3.If the password entered is valid, [SPEED] appears. If password entry failed, the menu returns to [SEtUP].

Note: Selecting a slower rate (e.g., 2 400 bps) will delay the response time (e.g., the time until an acti- vated alarm is reset).

3.Press the CAM/SET button to validate the selection.

4.Press the MON/ESC button to return to the [SPEED] menu.

Parity

The parity check mode is selected in this menu.

Baud Rate

When bit 7 of the MODE switch is in the ON position, you need to select the communication speed manually to match that of the WJ-SX350.

1.Display [SPEED], and press the CAM/SET button twice.

2.Select a parameter entering a bracket-enclosed num- ber, e.g., (3), or moving the joystick.

The default setting is 9 600 bps.

(1)2 400: 2 400 bps

(2)4 800: 4 800 bps

(3)9 600: 9 600 bps *

(4)19 200: 19 200 bps

1.Display [PrtY] and press the CAM/SET button twice.

2.Select a parameter with the joystick. The default setting is None.

n:None

E:Even parity

3.Press the CAM/SET button to confirm the selection.

4.Press the MON/ESC button to return to the [SPEED] menu.

Note: The baud rate and parity check mode of the WJ- SX350 and the controller must be the same, otherwise data communications will not function.

61

Image 59
Contents 360C Operating InstructionsEnglish Version Important Safety Instructions Contents Do not use any AC adapter other than the one supplied Handle the appliance with careDC 9 V Input Jack DC 9V Controller Number Switch Controller NoMode Selection Switches Mode Data Ports DataTemplate Mounting InstallationsWJ-FS616C Rear Panel Switch Setting SummaryPanasonic Security Data PSData Systems Monitor/Unit indicator MONITOR/ Unit Operate indicator OperateLogin indicator Login Alarm indicator Alarm Busy indicator BusyIris buttons IRIS, CLOSE/OPEN 4Home/Preset/Programme Preset button8Programme/Camera Setup/Camera Function button 9Setup/Function button SETUP/FUNCTION@3Wiper/Auxiliary 1 button WIPER/AUX @5Alarm Suspend button ALM Suspend@6Alarm Reset/Alarm Recall button ALM RESET/ALM @2Defroster/Auxiliary 2 button DEF/AUXConnection Example Installations PSDataSystem Connections Basic Connection Internal DiagramData Port Connection PS Data Daisy Chain Connection DIP Switch Setting PS DataMode Switch Setting for System Example Controller Number Setting PS DataButtons and Controls used for Setup Controller Setup Procedures PSDataPrior to Setup Setup Menus Wait Time Administrator AuthorizationBaud Rate ParityUnit a button Assignment User PasswordAdministrator Password User Password CertificationAvailable camera numbers Camera CleaningUnit Connection Test Basic Operating Flow Operating Procedures PSDataLog Out Login/LogoutLog Selecting with Unit A/UNIT B Button System Unit SelectionSelecting with Unit Number Camera Selection Monitor SelectionLens Control Home/Preset PositionCamera Control Pan/Tilt ControlIris Combination Camera ShortcutsCamera Selection Housing/AUX ControlSetting Data Multiplex Unit ControlElectronic Zoom Video Multiplexer ControlMultiscreen Selection Still PictureSequence Control Viewing PlaybackWJ-HD100 Shortcuts Digital Disk Recorder ControlWJ-HD500A Shortcuts Alarm Log Show/Hide Alarm LogAlarm Log 1 line Up Alarm Log 1 line Down Playback of Selected AlarmPress the ALM RESET/ALM Recall button Alarm OperationAlarm Reset Alarm RecallSystem Unit Setup Remote Setup of Units & CamerasCamera Setup Program Camera Patrol LearningCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C 1Auto Focus button Auto Focus 8Alarm Reset button ALM Reset@1Alarm Suspend button ALM Suspend 0Home/Decrement button Home@7Camera Set buttons Camera SET ON/OFF @5Preset Position button PRE Posi@8Set Up button SET UP ON/OFF @6Still button StillWJ-FS616C Installations For WJ-FS616/FS616CData Port Connection For Multiplexer DIP Switch Setting For MultiplexerWJ-FS616 Controller Number SettingSwitch Setting Procedures Unit VersionSetup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup AUX Control Operating Procedures For WJ-FS616/FS616C SystemVTR VCR Control Alarm SuspensionShortcut for Preset Position Setup General SetupFor WJ-SX350 Matrix Switcher System LED Display Monitor Camera Log-in indicator LoginFront View Template for WJ-SX350 Focus buttons Focus NEAR/FAR 3Preset Position button Preset POSI/CAM Posi@0Alarm Acknowledgment and Reset button ACK/RESET Iris buttons Iris CLOSE/OPEN@1@2Backward/Forward Sequence button SEQ BACK/FWD @3All Alarms Reset button ALL Reset@6Alarm Recall button Recall #1Set Up button SET UPExample below shows a typical system connection Installations For WJ-SX350Data Port Connection For WJ-SX350 DIP Switch Setting For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Pan/Tilt Control Camera Position Operation Operating Procedures For WJ-SX350Login & Logout Lens Control Auto Focus OperationWiper control Camera Housing ControlPan/Tilt Control Auto/Random Panning Auxiliary ControlSystem Status Display For System WJ-SX850 Matrix Switcher System Monitor indicator Monitor Front View Template for System 850 Matrix SwitcherLink indicator Link Camera indicator Camera Alarm indicator Alarm@0Alarm Acknowledge button ACK 3Programme Preset button Program Preset4Call Preset button Call Preset 9Alarm button ALARM, Disarm indicator Disarm@4Next button Next @1Alarm Reset button Reset@2Group Preset button Group Preset @3Previous button PrevPage Sensors System Matrix Switcher Installations For SystemTX B TX a RX B RX a Data Port ConnectionDIP Switch Setting Setup Procedures For System Setup Procedures Turn on the power switches of all system components Operating Procedures For SystemAppendix Controller SpecificationsALL Reset Panasonic Canada Inc