Panasonic WV-CU360C manual 0Iris buttons IRIS, CLOSE/OPEN, 1Focus buttons FOCUS, NEAR/FAR

Page 65

oJoystick Controller (UP/DOWN/L/R)

Used to manually operate the Pan/Tilt Head, or move the cursor in the camera menu on the active monitor screen.

UP: Upward

DOWN: Downward

L:Left

R:Right

!0Iris buttons (IRIS, CLOSE/OPEN)

Closes or opens the lens iris of cameras equipped with the specified lens.

When these buttons are pressed at the same time, the lens iris is reset to the factory default setting.

!1Focus buttons (FOCUS, NEAR/FAR)

Adjusts the lens focus of cameras equipped with the specified lens.

When these buttons are pressed at the same time, the lens focus is set automatically if the specified camera with the auto focus feature is equipped.

!2Zoom buttons (ZOOM, WIDE/TELE)

Zoom the image in or out if the camera is equipped with the specified lens.

!3Programme Preset button (PROGRAM PRESET)

In combination with the numeric buttons and CAMERA (ENTER) button, saves a preset position of the camera in a system equipped with the specified cameras.

To save a preset position, move the camera to the posi- tion to be preset and select a preset number by press- ing the numeric buttons. Hold down the PROGRAM PRESET button, then press the CAMERA (ENTER) but- ton.

!4Call Preset button (CALL PRESET)

In combination with the numeric buttons, moves the pan/tilt head of the selected camera to a preset position in a system equipped with the specified cameras.

!5Camera/Enter button [CAMERA (ENTER)]

CAMERA: Used for camera selection. Select a camera by pressing the corresponding numeric buttons, fol- lowed by the CAMERA (ENTER) button.

ENTER: In combination with the numeric buttons, enter numeric input, such as operator ID and password. It is also used to execute the currently highlighted selection and enter a submenu of the camera menu.

Pressing CAMERA (ENTER) while holding down the SHIFT button will activate the auto panning function of the selected camera (AUTO PAN).

!6Clear/Escape button [CLEAR (ESC)]

Clear: Clears numeric input from the LED display.

Escape: Escapes from the currently highlighted selec- tion and return to the previous page of the camera menu.

This button is also used to exit from alarm selection mode to normal operation mode.

!7Numeric buttons (0 - 9)

Used for numeric input into the system such as the camera and monitor number, sequence number, preset position, etc.

Pressing the buttons shown below while holding down the SHIFT button will select special functions.

1:Turns off the user auxiliary 1 switch of the receiver. (AUX1 OFF)

2:Turn on the user auxiliary 1 switch of the receiver. (AUX1 ON)

3:Turns on the housing wiper of the camera until these buttons are released. (WIPER)

4:Turns off the user auxiliary 2 switch of the receiver. (AUX2 OFF)

5:Turns on the user auxiliary 2 switch of the receiver. (AUX2 ON)

7:Turns off the housing defroster of the camera. (DEF OFF)

8:Turns on the housing defroster of the camera. (DEF ON)

!8Shift button (SHIFT)

Pressing this button in combination with buttons to which a special function has been assigned will acti- vate these functions.

!9Alarm button (ALARM), Disarm indicator (DISARM)

In combination with the Numeric buttons, selects an alarm. To select an activated alarm, press the numeric buttons, followed by the ALARM button.

Pressing this button repeatedly enables or disables the cameras and monitor assigned to perform the alarm activities.

The DISARM indicator next to the button is lit while alarm activities are disabled.

@0Alarm Acknowledge button (ACK)

Acknowledge an activated alarm. Select the alarm by pressing the numeric buttons, followed by the ALARM button. Select the desired alarm action number by pressing the numeric buttons, then press the ACK but- ton. The ACK indicator will light.

After acknowledging the alarm, press the RESET button to reset the alarm. The ACK indicator will go off.

67

Image 65
Contents 360C Operating InstructionsEnglish Version Important Safety Instructions Contents Do not use any AC adapter other than the one supplied Handle the appliance with careMode Selection Switches Mode Controller Number Switch Controller NoData Ports Data DC 9 V Input Jack DC 9VTemplate Mounting InstallationsWJ-FS616C Rear Panel Switch Setting SummaryPanasonic Security Data PSData Systems Login indicator Login Operate indicator OperateAlarm indicator Alarm Busy indicator Busy Monitor/Unit indicator MONITOR/ Unit8Programme/Camera Setup/Camera Function button 4Home/Preset/Programme Preset button9Setup/Function button SETUP/FUNCTION Iris buttons IRIS, CLOSE/OPEN@6Alarm Reset/Alarm Recall button ALM RESET/ALM @5Alarm Suspend button ALM Suspend@2Defroster/Auxiliary 2 button DEF/AUX @3Wiper/Auxiliary 1 button WIPER/AUXConnection Example Installations PSDataSystem Connections Basic Connection Internal DiagramData Port Connection PS Data Daisy Chain Connection DIP Switch Setting PS DataMode Switch Setting for System Example Controller Number Setting PS DataButtons and Controls used for Setup Controller Setup Procedures PSDataPrior to Setup Setup Menus Baud Rate Administrator AuthorizationParity Wait TimeAdministrator Password User PasswordUser Password Certification Unit a button AssignmentAvailable camera numbers Camera CleaningUnit Connection Test Basic Operating Flow Operating Procedures PSDataLog Out Login/LogoutLog Selecting with Unit A/UNIT B Button System Unit SelectionSelecting with Unit Number Camera Selection Monitor SelectionCamera Control Home/Preset PositionPan/Tilt Control Lens ControlIris Combination Camera ShortcutsSetting Housing/AUX ControlData Multiplex Unit Control Camera SelectionMultiscreen Selection Video Multiplexer ControlStill Picture Electronic ZoomSequence Control Viewing PlaybackWJ-HD100 Shortcuts Digital Disk Recorder ControlWJ-HD500A Shortcuts Alarm Log 1 line Up Show/Hide Alarm LogAlarm Log 1 line Down Playback of Selected Alarm Alarm LogAlarm Reset Alarm OperationAlarm Recall Press the ALM RESET/ALM Recall buttonSystem Unit Setup Remote Setup of Units & CamerasCamera Setup Program Camera Patrol LearningCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C @1Alarm Suspend button ALM Suspend 8Alarm Reset button ALM Reset0Home/Decrement button Home 1Auto Focus button Auto Focus@8Set Up button SET UP ON/OFF @5Preset Position button PRE Posi@6Still button Still @7Camera Set buttons Camera SET ON/OFFWJ-FS616C Installations For WJ-FS616/FS616CData Port Connection For Multiplexer DIP Switch Setting For MultiplexerSwitch Setting Procedures Controller Number SettingUnit Version WJ-FS616Setup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup AUX Control Operating Procedures For WJ-FS616/FS616C SystemVTR VCR Control Alarm SuspensionShortcut for Preset Position Setup General SetupFor WJ-SX350 Matrix Switcher System LED Display Monitor Camera Log-in indicator LoginFront View Template for WJ-SX350 @0Alarm Acknowledgment and Reset button ACK/RESET 3Preset Position button Preset POSI/CAM PosiIris buttons Iris CLOSE/OPEN Focus buttons Focus NEAR/FAR@6Alarm Recall button Recall @3All Alarms Reset button ALL Reset#1Set Up button SET UP @1@2Backward/Forward Sequence button SEQ BACK/FWDExample below shows a typical system connection Installations For WJ-SX350Data Port Connection For WJ-SX350 DIP Switch Setting For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Login & Logout Operating Procedures For WJ-SX350Lens Control Auto Focus Operation Pan/Tilt Control Camera Position OperationPan/Tilt Control Auto/Random Panning Camera Housing ControlAuxiliary Control Wiper controlSystem Status Display For System WJ-SX850 Matrix Switcher System Link indicator Link Camera indicator Camera Front View Template for System 850 Matrix SwitcherAlarm indicator Alarm Monitor indicator Monitor4Call Preset button Call Preset 3Programme Preset button Program Preset9Alarm button ALARM, Disarm indicator Disarm @0Alarm Acknowledge button ACK@2Group Preset button Group Preset @1Alarm Reset button Reset@3Previous button Prev @4Next button NextPage Sensors System Matrix Switcher Installations For SystemTX B TX a RX B RX a Data Port ConnectionDIP Switch Setting Setup Procedures For System Setup Procedures Turn on the power switches of all system components Operating Procedures For SystemAppendix Controller SpecificationsALL Reset Panasonic Canada Inc