●Administrator Authorization
1.Press the CAM/SET button while [SEtUP] is displayed. The [- - - -
2.Enter a password with the numeric buttons, then press the CAM/SET button.
The default setting is [12345].
3.[SPEED] appears when the right password is entered. If password entry failed, the menu returns to [- - - -
Notes:
•We recommend that you register a new password dif- ferent from “12345” in [SUSrP], and note down the reg- istered password for future reference.
•Powering up the controller while holding down numeric buttons 2, 4 and 5 simultaneously will reset the pass- word to “12345”. Remember that this procedure also resets all other menu parameters to the default settings.
●Baud Rate
In this menu, the communication speed (bps: bits per sec- ond) is selected. The communication speed should match that of the other units connected in the communication chain.
1.Display [SPEED] and press the CAM/SET button twice.
2.Select a parameter entering a
The default setting is 19 200 bps.
(1)2 400: 2 400 bps
(2)4 800: 4 800 bps
(3)9 600: 9 600 bps
(4)19 200: 19 200 bps
Note: Selecting a slower rate (e.g., 2 400 bps) will delay the response time (e.g., the time until an acti- vated alarm is reset).
3.Press the CAM/SET button to validate the selection.
4.Press the ESC button to go back to the previous menu.
●Parity
In this menu, the parity check mode is selected.
1.Display [PrtY] and press the CAM/SET button twice.
2.Select a parameter with the joystick. The default setting is None.
n:None
E:Even parity
3.Press the CAM/SET button to validate the selection.
4.Press the ESC button to go back to the previous menu.
●Wait Time
In this menu a wait time is selected. The controller will retransmit data when there is no response during the speci- fied wait time.
1.Display [LJAit] and press the CAM/SET button twice.
2.Select a parameter with the joystick. The default setting is Off.
(1)OFF: Off, no retransmission of data
(2)100: 100 ms
(3)200: 200 ms
(4)400: 400 ms
(5)500: 500 ms
(6)1 000: 1 s
3.Press the CAM/SET button to validate the selection.
4.Press the ESC button to go back to the previous menu.
The following two menus should be maintained in the default condition.
●Controller Unit-Group Address
●System Unit-Group Address
19