Panasonic WV-CU360C manual ALL Reset

Page 76

ALL RESET

The System Controller WV-CU360C can be reset to the default settings.

1.Remove the DC plug of the AC adapter from the con- troller.

2.While pressing numeric buttons 2, 4 and 6 simultane- ously, plug in the DC plug.

3.When all indicators light up, resetting is completed.

Note: Keep the DC plug connected to the controller until the reset procedure is completed.

1

4

7

HOME

ESC

2

3

5

6

8

9

PRESET

0

SET

PROGRAM

PRESET

79

Image 76
Contents Operating Instructions 360CEnglish Version Important Safety Instructions Contents Handle the appliance with care Do not use any AC adapter other than the one suppliedController Number Switch Controller No Mode Selection Switches ModeData Ports Data DC 9 V Input Jack DC 9VInstallations Template MountingRear Panel Switch Setting Summary WJ-FS616CPanasonic Security Data PSData Systems Operate indicator Operate Login indicator LoginAlarm indicator Alarm Busy indicator Busy Monitor/Unit indicator MONITOR/ Unit4Home/Preset/Programme Preset button 8Programme/Camera Setup/Camera Function button9Setup/Function button SETUP/FUNCTION Iris buttons IRIS, CLOSE/OPEN@5Alarm Suspend button ALM Suspend @6Alarm Reset/Alarm Recall button ALM RESET/ALM@2Defroster/Auxiliary 2 button DEF/AUX @3Wiper/Auxiliary 1 button WIPER/AUXSystem Connections Installations PSDataConnection Example Data Port Connection PS Data Internal DiagramBasic Connection DIP Switch Setting PS Data Daisy Chain ConnectionController Number Setting PS Data Mode Switch Setting for System ExamplePrior to Setup Controller Setup Procedures PSDataButtons and Controls used for Setup Setup Menus Administrator Authorization Baud RateParity Wait TimeUser Password Administrator PasswordUser Password Certification Unit a button AssignmentUnit Connection Test Camera CleaningAvailable camera numbers Operating Procedures PSData Basic Operating FlowLog Login/LogoutLog Out Selecting with Unit Number System Unit SelectionSelecting with Unit A/UNIT B Button Monitor Selection Camera SelectionHome/Preset Position Camera ControlPan/Tilt Control Lens ControlCombination Camera Shortcuts IrisHousing/AUX Control SettingData Multiplex Unit Control Camera SelectionVideo Multiplexer Control Multiscreen SelectionStill Picture Electronic ZoomViewing Playback Sequence ControlDigital Disk Recorder Control WJ-HD100 ShortcutsWJ-HD500A Shortcuts Show/Hide Alarm Log Alarm Log 1 line UpAlarm Log 1 line Down Playback of Selected Alarm Alarm LogAlarm Operation Alarm ResetAlarm Recall Press the ALM RESET/ALM Recall buttonCamera Setup Remote Setup of Units & CamerasSystem Unit Setup Camera Patrol Learning ProgramCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C 8Alarm Reset button ALM Reset @1Alarm Suspend button ALM Suspend0Home/Decrement button Home 1Auto Focus button Auto Focus@5Preset Position button PRE Posi @8Set Up button SET UP ON/OFF@6Still button Still @7Camera Set buttons Camera SET ON/OFFInstallations For WJ-FS616/FS616C WJ-FS616CDIP Switch Setting For Multiplexer Data Port Connection For MultiplexerController Number Setting Switch Setting ProceduresUnit Version WJ-FS616Setup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup Operating Procedures For WJ-FS616/FS616C System AUX ControlAlarm Suspension VTR VCR ControlGeneral Setup Shortcut for Preset Position SetupFor WJ-SX350 Matrix Switcher System Front View Template for WJ-SX350 Log-in indicator LoginLED Display Monitor Camera 3Preset Position button Preset POSI/CAM Posi @0Alarm Acknowledgment and Reset button ACK/RESETIris buttons Iris CLOSE/OPEN Focus buttons Focus NEAR/FAR@3All Alarms Reset button ALL Reset @6Alarm Recall button Recall#1Set Up button SET UP @1@2Backward/Forward Sequence button SEQ BACK/FWDInstallations For WJ-SX350 Example below shows a typical system connectionDIP Switch Setting For WJ-SX350 Data Port Connection For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Operating Procedures For WJ-SX350 Login & LogoutLens Control Auto Focus Operation Pan/Tilt Control Camera Position OperationCamera Housing Control Pan/Tilt Control Auto/Random PanningAuxiliary Control Wiper controlSystem Status Display For System WJ-SX850 Matrix Switcher System Front View Template for System 850 Matrix Switcher Link indicator Link Camera indicator CameraAlarm indicator Alarm Monitor indicator Monitor3Programme Preset button Program Preset 4Call Preset button Call Preset9Alarm button ALARM, Disarm indicator Disarm @0Alarm Acknowledge button ACK@1Alarm Reset button Reset @2Group Preset button Group Preset@3Previous button Prev @4Next button NextPage Installations For System Sensors System Matrix SwitcherData Port Connection TX B TX a RX B RX aDIP Switch Setting Setup Procedures For System Setup Procedures Operating Procedures For System Turn on the power switches of all system componentsAppendix Specifications ControllerALL Reset Panasonic Canada Inc