■Camera Control
Cameras and their peripherals are controlled from the WV- CU360C as follows. Some of the descriptions may not be applicable if they refer to devices not equipped in your sys- tem.
The operating procedures on the following pages assume that you have selected a system unit and a monitor.
●Pan/Tilt Control
Proceed as follows to control a combination camera or an ordinary camera mounted on a pan/tilt head.
1.Move the pan/tilt head in the desired direction with the joystick controller.
Joystick
2.Press the ZOOM TELE button to optically bring the object closer, or press the ZOOM WIDE button to opti- cally widen the scene.
ZOOM
WIDE |
|
|
| TELE |
|
|
| ||
|
|
|
|
|
3.Press the IRIS CLOSE button to close the iris, or the IRIS OPEN button to open the iris.
If the IRIS CLOSE and IRIS OPEN buttons are pressed simultaneously, the iris is reset to the default.
IRIS
CLOSE |
|
|
|
|
| OPEN |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
IRIS RESET
2.To slowly move the pan/tilt head, move the joystick while holding down the SLOW button.
SEQ PAUSE
SLOW
●Lens Control
This allows you to control a motorized lens.
1.Press the FOCUS NEAR or FOCUS FAR button to adjust the lens focus while watching the monitor.
If you are using a camera with an auto focus feature, the lens focus can be automatically adjusted by press- ing the FOCUS NEAR and FOCUS FAR buttons simul- taneously.
FOCUS
NEAR |
|
|
|
|
| FAR |
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
AUTO FOCUS
●Home/Preset Position
The camera moves to the preset position or back to the home position, and the picture of the camera in that posi- tion appears on the monitor.
1.Press the HOME/PRESET button to move the camera back to the home position.
HOME/PRESET
PROGRAM
PRESET
2.Select a preset position number using the numeric but- tons, then press the HOME/PRESET button to move the camera to the position.
HOME/PRESET
MONCAM
PROGRAM
ESC | LOGOUT SET | PRESET |
|
|