Panasonic WV-CU360C manual Installations, Template Mounting

Page 7

INSTALLATIONS

Template Mounting

The system controller is provided with four templates including one for PS Data system that is placed (not taped yet) on the surface of the controller when shipped from the factory.

OPERATE

LOGIN

ALARM

MONITOR

CAMERA

BUSY

PROHIBITED

 

UNIT

 

 

 

 

 

 

 

System Controller WV-CU360C

 

 

PROGRAM

 

 

 

 

 

 

SETUP

CAM SETUP

 

 

 

IRIS

 

 

 

 

 

 

 

CLOSE

OPEN

SHIFT

FUNCTION

CAM FUNCTION

 

 

 

IRIS RESET

UP

 

 

 

 

 

 

ALM RESET

ALM SUSPEND

AUTO

 

 

UNIT A

FOCUS

 

 

 

NEAR

FAR

ALM RECALL

B/W

UNIT

AUTO FOCUS

VCR CAM

MULTI SCREEN SELECT

DEF

 

 

 

L

R

 

 

 

 

 

 

 

 

 

 

 

UNIT B

ZOOM

 

 

 

AUX 2

 

 

WIDE

TELE

 

STILL

EL-ZOOM

WIPER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

+

AUX 1

 

 

 

 

 

SEQ PAUSE

SEQUENCE

PATROL PLAY

MON

CAM

HOME/PRESET

 

 

SLOW

PATROL

PATROL

ESC

LOGOUT SET

PROGRAM

 

 

 

STOP

LEARN

 

 

PRESET

 

 

OPERATE

LOCK

ALARM

UNIT

CAMERA

 

System Controller

WV-CU360C

 

 

 

 

 

 

1. Select the correct template for your system.

Select the PS Data template when your system includes any of the following:

Video Multiplexer (WJ-FS309/316) Digital Disk Recorder (WJ-HD100/500A) Data Multiplex Unit (WJ-MP204C)

Select the template marked “For Multiplexer” if your system includes a WJ-FS616C Video Multiplexer.

Select the template marked “For Matrix Switcher” if your system includes a WJ-SX350 Matrix Switcher.

Select the template marked “For Matrix Switcher (System SX850)” if your system includes a WJ-SX850 Matrix Switcher.

2.Peel off the tape, and fix the template in the guide slots on the front panel of the controller.

 

 

 

 

 

For Multiplexer

 

MULTI

 

 

CAMERA SITE CONTROL

ALT

SPOT

 

 

 

SCREEN

 

IRIS

 

 

 

 

 

 

 

 

 

CLOSE

OPEN

 

 

VTR

 

IRIS RESET

UP

ALM RESET SEQUENCE

AUTO/+

FOCUS

 

CAM

 

NEAR

FAR

ALL RESET

 

 

 

 

AUX 2

 

 

 

ALM SUSPEND

EL-ZOOM

MULTI SELECT

 

 

 

 

L

R

 

 

 

 

 

 

 

 

 

 

 

 

HOME/-

ZOOM

 

 

FUNCTION

PRE-POSI

STILL

 

 

 

TELE

WIDE

 

 

 

AUX 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

CAMERA SET

SETUP

UNIT

CAM

AUTO

 

 

 

FOCUS

 

 

 

ON

OFF

ON/OFF

ESC

SET

 

 

 

 

T/L MODE

 

 

 

 

 

 

 

OPERATE

LOGIN

ALARM

MONITOR

CAMERA

BUSY

PROHIBITED

System Controller

WV-CU360C

 

 

 

 

 

 

 

 

 

 

 

ALM

RESET

 

 

 

 

 

 

 

 

ALL

RESET

 

 

 

 

ALM

 

 

 

 

SUSPEND

 

 

 

 

 

EL-

 

 

 

 

ZOOM

 

 

 

FUNCTION

 

 

 

 

 

PRE-

 

 

 

 

 

POSI

 

 

 

 

 

STILL

 

 

CAMERA

SET

 

 

ON

OFF

SET UP

 

 

T/L

MODE

ON/OFF

UNIT

 

 

 

 

 

 

 

 

ESC

 

 

 

OPERATE

 

 

 

 

LOCK

 

 

 

 

ALARM

 

 

ALT

MULTI

 

UNIT

 

 

 

 

 

 

SCREEN

 

 

 

 

SPOT

 

 

SEQUENCE

VTR

 

 

 

 

 

 

 

 

CAM

 

 

MULTI

SELECT

 

 

 

 

 

 

AUTO/+

 

 

 

 

 

 

 

AUX

NEAR

 

 

 

2

 

 

 

HOME/-

 

 

 

AUX

TELE

ZOOM

 

 

1

 

 

CAM

AUTO

 

WIDE

 

 

 

 

SET

 

FOCUS

 

 

CAMERA

 

CAMERA

SITE

 

System

Controller

 

CLOSE

IRIS

 

CONTRIL

 

 

 

WV-

 

 

For

 

CU

 

 

 

 

 

 

Multiplexer

IRIS

RESET

 

OPEN

 

 

 

 

 

 

 

 

 

 

FOCUS

 

 

 

 

 

 

 

 

FAR

 

 

 

UP

 

 

 

L

 

 

 

 

 

 

 

 

 

 

 

 

R

 

 

 

DOWN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Matrix Switcher

 

 

 

 

 

 

CAMERA SITE CONTROL

ALT

PAUSE

FUNCTION

IRIS

 

 

 

 

 

 

CLOSE

 

 

 

OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IRIS RESET

UP

ACK/RESET

BACK

FWD

AUX

FOCUS

 

 

 

SEQ

 

 

 

 

 

 

NEAR

 

FAR

 

-1 CAM

+1 CAM

 

 

 

AUTO FOCUS

 

ALL RESET

DEC

INC

 

 

 

L

R

 

 

 

 

 

 

 

 

 

 

 

PAN

ZOOM

 

RECALL

BACK

FWD

 

 

TELE

WIDE

 

 

 

 

 

 

 

 

HISTORY

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

STATUS

 

 

MON

CAM

PRESET

 

 

 

 

POSI

 

 

 

CAM

SETUP

ESC

SET

CAM

 

 

 

MENU

 

 

POSI

 

 

 

 

 

 

 

 

OPERATE

LINK

ALARM

MONITOR

CAMERA

BUSY

PROHIBITED

WV-CU360C

 

 

 

 

 

 

 

System Controller

 

 

 

 

 

 

 

For Matrix Switcher (System 850)

 

 

 

 

 

 

CAMERA SITE CONTROL

 

ALARM

ACK

RESET

 

 

 

 

IRIS

 

 

 

 

 

 

 

CLOSE

OPEN

 

DISARM

 

ALL RESET

 

 

 

 

IRIS RESET

UP

 

 

 

 

 

PROGRAM

 

GROUP PRESET

PREV

NEXT

CAM ID

GEN

 

FOCUS

 

PRESET

 

 

NEAR

FAR

OPE ID

S-CTL ID

 

AUX1 OFF

AUX1 ON

WIPER

 

AUTO FOCUS

 

 

 

 

ALM S

VLD S

SYS S

 

 

LOG OUT

PAUSE

STOP

 

MDN STATUS

ALL

 

L

R

 

 

 

 

 

 

 

 

 

 

 

 

 

CALL

ZOOM

 

 

CAM MENU OFF

CAM MENU ON

AUX2 OFF

AUX2 ON

 

PRESET

 

 

 

WIDE

TELE

 

 

GROUP

TOUR

ALM H

VLD H

 

 

F1

SEQ

SEQ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOWN

 

 

 

DEF OFF

DEF ON

CLEAR

CAMERA

 

 

 

OSD

 

 

 

 

 

F2

MONITOR

 

 

(ESC)

(ENTER)

 

 

CAM FUNC

 

LOCK

SHIFT

BLK

EXIT

AUTO

 

 

 

 

OSD SERVICE

 

 

 

PAN

 

 

1 2 3 4 5 6 7 8 9

0

7

Image 7
Contents 360C Operating InstructionsEnglish Version Important Safety Instructions Contents Do not use any AC adapter other than the one supplied Handle the appliance with careDC 9 V Input Jack DC 9V Controller Number Switch Controller NoMode Selection Switches Mode Data Ports DataTemplate Mounting InstallationsWJ-FS616C Rear Panel Switch Setting SummaryPanasonic Security Data PSData Systems Monitor/Unit indicator MONITOR/ Unit Operate indicator OperateLogin indicator Login Alarm indicator Alarm Busy indicator BusyIris buttons IRIS, CLOSE/OPEN 4Home/Preset/Programme Preset button8Programme/Camera Setup/Camera Function button 9Setup/Function button SETUP/FUNCTION@3Wiper/Auxiliary 1 button WIPER/AUX @5Alarm Suspend button ALM Suspend@6Alarm Reset/Alarm Recall button ALM RESET/ALM @2Defroster/Auxiliary 2 button DEF/AUXSystem Connections Installations PSDataConnection Example Data Port Connection PS Data Internal DiagramBasic Connection Daisy Chain Connection DIP Switch Setting PS DataMode Switch Setting for System Example Controller Number Setting PS DataPrior to Setup Controller Setup Procedures PSDataButtons and Controls used for Setup Setup Menus Wait Time Administrator AuthorizationBaud Rate ParityUnit a button Assignment User PasswordAdministrator Password User Password CertificationUnit Connection Test Camera CleaningAvailable camera numbers Basic Operating Flow Operating Procedures PSDataLog Login/LogoutLog Out Selecting with Unit Number System Unit SelectionSelecting with Unit A/UNIT B Button Camera Selection Monitor SelectionLens Control Home/Preset PositionCamera Control Pan/Tilt ControlIris Combination Camera ShortcutsCamera Selection Housing/AUX ControlSetting Data Multiplex Unit ControlElectronic Zoom Video Multiplexer ControlMultiscreen Selection Still PictureSequence Control Viewing PlaybackWJ-HD100 Shortcuts Digital Disk Recorder ControlWJ-HD500A Shortcuts Alarm Log Show/Hide Alarm LogAlarm Log 1 line Up Alarm Log 1 line Down Playback of Selected AlarmPress the ALM RESET/ALM Recall button Alarm OperationAlarm Reset Alarm RecallCamera Setup Remote Setup of Units & CamerasSystem Unit Setup Program Camera Patrol LearningCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C 1Auto Focus button Auto Focus 8Alarm Reset button ALM Reset@1Alarm Suspend button ALM Suspend 0Home/Decrement button Home@7Camera Set buttons Camera SET ON/OFF @5Preset Position button PRE Posi@8Set Up button SET UP ON/OFF @6Still button StillWJ-FS616C Installations For WJ-FS616/FS616CData Port Connection For Multiplexer DIP Switch Setting For MultiplexerWJ-FS616 Controller Number SettingSwitch Setting Procedures Unit VersionSetup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup AUX Control Operating Procedures For WJ-FS616/FS616C SystemVTR VCR Control Alarm SuspensionShortcut for Preset Position Setup General SetupFor WJ-SX350 Matrix Switcher System Front View Template for WJ-SX350 Log-in indicator LoginLED Display Monitor Camera Focus buttons Focus NEAR/FAR 3Preset Position button Preset POSI/CAM Posi@0Alarm Acknowledgment and Reset button ACK/RESET Iris buttons Iris CLOSE/OPEN@1@2Backward/Forward Sequence button SEQ BACK/FWD @3All Alarms Reset button ALL Reset@6Alarm Recall button Recall #1Set Up button SET UPExample below shows a typical system connection Installations For WJ-SX350Data Port Connection For WJ-SX350 DIP Switch Setting For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Pan/Tilt Control Camera Position Operation Operating Procedures For WJ-SX350Login & Logout Lens Control Auto Focus OperationWiper control Camera Housing ControlPan/Tilt Control Auto/Random Panning Auxiliary ControlSystem Status Display For System WJ-SX850 Matrix Switcher System Monitor indicator Monitor Front View Template for System 850 Matrix SwitcherLink indicator Link Camera indicator Camera Alarm indicator Alarm@0Alarm Acknowledge button ACK 3Programme Preset button Program Preset4Call Preset button Call Preset 9Alarm button ALARM, Disarm indicator Disarm@4Next button Next @1Alarm Reset button Reset@2Group Preset button Group Preset @3Previous button PrevPage Sensors System Matrix Switcher Installations For SystemTX B TX a RX B RX a Data Port ConnectionDIP Switch Setting Setup Procedures For System Setup Procedures Turn on the power switches of all system components Operating Procedures For SystemAppendix Controller SpecificationsALL Reset Panasonic Canada Inc