Panasonic WV-CU360C manual Controller Setup, Administrator Authorization

Page 46

Controller Setup

Set up the baud rate and parity check mode for the controller while observing the LED on the front panel.

Menu

 

Setup Menus

 

 

Parameter Selection (default*)

LED Display

Reading

Function

 

Selection

 

 

 

 

 

 

 

 

 

 

 

CAM

 

 

 

Setup

Initial

 

LED prompts you to enter pass-

 

 

Display

 

word

 

 

 

SET

 

 

 

 

 

No

 

 

 

 

Enter a 5-digit password,

 

 

 

 

 

 

 

Administrator

Authorization

 

press CAM (12345*)

OK

 

Password

 

 

blinking

Prompt

 

 

 

 

 

 

 

SET

 

 

 

 

 

 

 

 

 

Press

 

Move Joystick

 

Baud Rate

twice

(1) 2 400 (2) 4 800 (3) 9 600*

Speed

 

UP and down

 

(bps)

CAM

(4) 19 200

to select

 

 

 

 

 

 

 

L

R

 

 

SET

 

 

 

 

 

 

DOWN

 

 

 

MON

 

UP

 

Parity

Parity Check

 

(1) None* (2) Even

 

 

 

L

R

 

 

 

 

 

 

 

 

ESC

 

Administrator Authorization

1.Press the CAM/SET button while [SEtUP] is displayed. The [- - - - -] prompt appears.

2.Enter a password with the numeric buttons, then press the CAM/SET button.

The default setting is [12345].

3.If the password entered is valid, [SPEED] appears. If password entry failed, the menu returns to [SEtUP].

Baud Rate

In this menu, the communication speed (bps: bits per sec- ond) is selected. The communication speed should match that of the WJ-FS616/FS616C.

1.Display [SPEED] and press the CAM/SET button twice.

2.Select a parameter entering a bracket-enclosed num- ber, e.g., (3), moving the joystick to right and left, or pressing the [+] and [–] buttons.

The default setting is 9 600 bps.

(1)2 400: 2 400 bps

(2)4 800: 4 800 bps

(3)9 600: 9 600 bps

(4)19 200: 19 200 bps

Note: Selecting a slower rate (e.g., 2 400 bps) will delay the response time (e.g., the time until an activated alarm is reset).

3.Press the CAM/SET button to validate the selection.

4.Press the ESC button to go back to the previous menu.

Parity

In this menu the parity check mode is selected.

1.Display [PrtY] and press the CAM/SET button twice.

2.Select a parameter with the joystick. The default setting is None.

n:None

E:Even parity

3.Press the CAM/SET button to validate the selection.

47

Image 46
Contents Operating Instructions 360CEnglish Version Important Safety Instructions Contents Handle the appliance with care Do not use any AC adapter other than the one suppliedData Ports Data Controller Number Switch Controller NoMode Selection Switches Mode DC 9 V Input Jack DC 9VInstallations Template MountingRear Panel Switch Setting Summary WJ-FS616CPanasonic Security Data PSData Systems Alarm indicator Alarm Busy indicator Busy Operate indicator OperateLogin indicator Login Monitor/Unit indicator MONITOR/ Unit9Setup/Function button SETUP/FUNCTION 4Home/Preset/Programme Preset button8Programme/Camera Setup/Camera Function button Iris buttons IRIS, CLOSE/OPEN@2Defroster/Auxiliary 2 button DEF/AUX @5Alarm Suspend button ALM Suspend@6Alarm Reset/Alarm Recall button ALM RESET/ALM @3Wiper/Auxiliary 1 button WIPER/AUXSystem Connections Installations PSDataConnection Example Data Port Connection PS Data Internal DiagramBasic Connection DIP Switch Setting PS Data Daisy Chain ConnectionController Number Setting PS Data Mode Switch Setting for System ExamplePrior to Setup Controller Setup Procedures PSDataButtons and Controls used for Setup Setup Menus Parity Administrator AuthorizationBaud Rate Wait TimeUser Password Certification User PasswordAdministrator Password Unit a button AssignmentUnit Connection Test Camera CleaningAvailable camera numbers Operating Procedures PSData Basic Operating FlowLog Login/LogoutLog Out Selecting with Unit Number System Unit SelectionSelecting with Unit A/UNIT B Button Monitor Selection Camera SelectionPan/Tilt Control Home/Preset PositionCamera Control Lens ControlCombination Camera Shortcuts IrisData Multiplex Unit Control Housing/AUX ControlSetting Camera SelectionStill Picture Video Multiplexer ControlMultiscreen Selection Electronic ZoomViewing Playback Sequence ControlDigital Disk Recorder Control WJ-HD100 ShortcutsWJ-HD500A Shortcuts Alarm Log 1 line Down Playback of Selected Alarm Show/Hide Alarm LogAlarm Log 1 line Up Alarm LogAlarm Recall Alarm OperationAlarm Reset Press the ALM RESET/ALM Recall buttonCamera Setup Remote Setup of Units & CamerasSystem Unit Setup Camera Patrol Learning ProgramCamera Preset Position For WJ-FS616C Multiplexer System Front View Template for WJ-FS616C 0Home/Decrement button Home 8Alarm Reset button ALM Reset@1Alarm Suspend button ALM Suspend 1Auto Focus button Auto Focus@6Still button Still @5Preset Position button PRE Posi@8Set Up button SET UP ON/OFF @7Camera Set buttons Camera SET ON/OFFInstallations For WJ-FS616/FS616C WJ-FS616CDIP Switch Setting For Multiplexer Data Port Connection For MultiplexerUnit Version Controller Number SettingSwitch Setting Procedures WJ-FS616Setup Procedures For WJ-FS616/FS616C Controller Setup COM Port Setup Operating Procedures For WJ-FS616/FS616C System AUX ControlAlarm Suspension VTR VCR ControlGeneral Setup Shortcut for Preset Position SetupFor WJ-SX350 Matrix Switcher System Front View Template for WJ-SX350 Log-in indicator LoginLED Display Monitor Camera Iris buttons Iris CLOSE/OPEN 3Preset Position button Preset POSI/CAM Posi@0Alarm Acknowledgment and Reset button ACK/RESET Focus buttons Focus NEAR/FAR#1Set Up button SET UP @3All Alarms Reset button ALL Reset@6Alarm Recall button Recall @1@2Backward/Forward Sequence button SEQ BACK/FWDInstallations For WJ-SX350 Example below shows a typical system connectionDIP Switch Setting For WJ-SX350 Data Port Connection For WJ-SX350For version 6.00 or later, set the switches as shown below Controller Setup Procedures For WJ-SX350 Setup Procedures Lens Control Auto Focus Operation Operating Procedures For WJ-SX350Login & Logout Pan/Tilt Control Camera Position OperationAuxiliary Control Camera Housing ControlPan/Tilt Control Auto/Random Panning Wiper controlSystem Status Display For System WJ-SX850 Matrix Switcher System Alarm indicator Alarm Front View Template for System 850 Matrix SwitcherLink indicator Link Camera indicator Camera Monitor indicator Monitor9Alarm button ALARM, Disarm indicator Disarm 3Programme Preset button Program Preset4Call Preset button Call Preset @0Alarm Acknowledge button ACK@3Previous button Prev @1Alarm Reset button Reset@2Group Preset button Group Preset @4Next button NextPage Installations For System Sensors System Matrix SwitcherData Port Connection TX B TX a RX B RX aDIP Switch Setting Setup Procedures For System Setup Procedures Operating Procedures For System Turn on the power switches of all system componentsAppendix Specifications ControllerALL Reset Panasonic Canada Inc