3.Connect ground wire (green or bare) of direct wire cable to external ground conductor screw. Tighten screw.
F
A. External ground conductor screw
B. Neutral ground wire
C. Ground wire (green or bare) of power supply cord
D. 3/4"(!.9 cm) UL listed strain relief
E. Center
E Neutral wire (white or center wire)
4.Place the hooked ends of the other direct wire cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.
!!!!
5.Tighten strain relief screw.
6.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
7.You have completed your electrical connection. Now go to "Venting Requirements."
Use where local codes permit connecting
E
A
CG F
A.
B.
C. Neutral prong
D. Spade terminals with upturned ends
E. _" (1.9 cm) UL Iisted strain relief
E Ring terminals
G. Neutral wire (white or center wire)
1.Loosen or remove center
2.Connect neutral wire (white or center wire) of power supply cord to the center,
A. External ground conductor screw
B. Neutral ground wire
C. Center
D. Neutral wire (white or center wire)
E. _" (1.9 cm) UL Iisted strain relief
3.Connect the other wires to outer terminal block screws. Tighten screws.
!!!!
4.Tighten strain relief screws.
5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with
6.You have completed your electrical connection. Now go to "Venting Requirements."
Use where local codes permit connecting
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.
Strip 31/2''(8.9 cm) of outer covering from end of cable. Strip insulation back 1" (2.5 cm). If using
11