To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

[] If local codes do not permit the connection of a neutral ground wire to the neutral wire, see "Optional 3-wire connection" in the "Electrical Connection" section.

This dryer is manufactured ready to install with a 3-wire electrical supply connection. The neutral ground wire is permanently connected to the neutral conductor (white wire) within the dryer. If the dryer is installed with a 4-wire electrical supply connection, the neutral ground wire must be removed from the external ground conductor screw (green screw), and secured under the neutral terminal (center or white wire) of the terminal block. When the neutral ground wire is secured under the neutral terminal (center or white wire) of the terminal block, the dryer cabinet is isolated from the neutral conductor.

A 4-wire power supply connection must be used when the appliance is installed in a location where grounding through the neutral conductor is prohibited. Grounding through the neutral is prohibited for (1) new branch-circuit installations,

(2)mobile homes, (3) recreational vehicles, and (4) areas where local codes prohibit grounding through the neutral conductors.

If using a power supply cord:

Use a UL listed power supply cord kit marked for use with clothes dryers. The kit should contain:

[] A UL listed 30-amp power supply cord, rated

120/240 volt minimum. The cord should be type SRD or SRDT and be at least 4 ft (1.22 m) long. The wires that connect to the dryer must end in ring terminals or spade terminals with upturned ends.

[] A UL listed strain relief.

If your outlet looks like this:

4-wire receptacle (14-30R)

Then choose a 4-wire power supply cord with ring or spade terminals and UL listed strain relief. The 4-wire power supply cord, at least 4 ft (1.22 m) long, must have four 10-gauge copper wires and match a 4-wire receptacle of NEMA Type 14-30R. The ground wire (ground conductor) may be either green or bare. The neutral conductor must be identified by a white cover.

If your outlet looks like this:

3-wire receptacle (10-30R)

Then choose a 3-wire power supply cord with ring or spade terminals and UL listed strain relief. The 3-wire power supply cord, at least 4 ft (1.22 m) long, must have three 10-gauge copper wires and match a 3-wire receptacle of NEMA Type 10-30R.

If connecting by direct wire:

Power supply cable must match power supply (4-wire or 3-wire) and be:

[] Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), protected with flexible metallic conduit. All current-carrying wires must be insulated.

[] 10-gauge solid copper wire (do not use aluminum).

[] At least 5 ft (1.52 m) long.

GROUNDING INSTRUCTIONS

[] For a grounded, cord-connected dryer:

This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.

[] For a permanently connected dryer:

This dryer must be connected to a grounded metal, permanent wiring system, or an equipment-grounding conductor must be run with the circuit conductors and connected to the equipment-grounding terminal or lead on the dryer.

WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug on the power supply cord: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.

SAVE THESE INSTRUCTIONS

Image 7
Contents Electric Dryer Table of Contents Master Protection Agreements Kenmore Elite Appliance WarrantyONE Year Limited Warranty Protection AgreementsYour safety and the safety of others are very important Dryer SafetyYou will need 80O-4-MY-HOM E If using a power supply cordParts supplied Parts neededMobile Home Additional Installation Requirements Installation ClearancesIt is your responsibility Electrical Connection If connecting by direct wireIf your outlet looks like this Ecb ca Direct WireWire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct Wire CG F Optional 3-wire connection Rigid metal vent If using an existing vent systemIf this is a new vent system Vent material ExhaustSpecial provisions for mobile home installations Optional exhaust installationsHoods Rigid Metal Vent system chartDetermine vent path Number Type Box or Angled G0 turns Vent Louvered HoodsEc, ne ,-@se Remove the door assembly If the dryer will not start, check the following To use an Auto Dry Cycle Dryer USECycle tips To use a Timed CycleTo stop or pause your dryer at any time Drying tipsAuto Dry Cycles Express DRY TM SteamCare Preset Cycle SettingsHeavy Duty Ultra DelicateAuto Dry Cycle Modifiers Changing Modifiers and Options after pressing Start Changing the Preset Dryness Level SettingsTo use the dryer rack Dryer Care For direct-wired dryers Unusualsounds TroubleshootingDryer displaying code message No heatHas the Air Dry modifier been selected? Is the lint screen clogged with lint?Are fabric softener sheets blocking the grille? Is the exhaust vent the correct length?Is the dryer being used for the first time? Loads are wrinkledOdors Lint on load Is the lint screen clogged?Contratos DE Proteccion Garantia Limitada DE UN Aiio Seguridad DE LA SecadoraExclusion DE Garantias Implcitas Limitacion DE Recursos Piezas suministradas Instrucciones DE InstalacionPiezas necesarias Peligro de Explosion Si emplea un cable de suministro elctricoUsted necesitara Si el contacto de pared luce como ste Usted es responsable deLas instalaciones en casas rodantes necesitan Conexibn elctricaSi hace la conexi6n con cableado directo Si el contacto de pared luce come steCable de suministro elctrico Cable directo Con Estilo 2 Protector de cables para cable directoConexibn de 4 hilos Cable de suministro elctrico Conexibn de 4 hilos Cable directo CG F Conexibn opcional de 3 hilos Ventilaci6n Ducto de escape de metal flexibleCodos AbrazaderasPeligro de Incendio Instalaciones opcionales de escapeCuadro del sistema de ventilacibn No. de Tipo de ducto Capotas de Vueltas Ventilaci6n deDe 90 o Caja o tipo Codos Persiana Determinacibn de la via del ducto de escapeRe& c de C6mo invertir el tope Si la secadora no funciona, revise Io siguiente Peligro de Explosi6n USO DE LA SecadoraSistema de secado de doble acci6n Para usar un ciclo programado Para hacer cambios durante un ciclo de secado automaticoPara usar un ciclo de secado automatico Auto Dry Cycle Para usar un Ciclo con vapor SteamOare CycleMojado Wet Para reanudar la marcha de la secadoraSugerencias de secado Sugerencias de ciclosTowels Ciclos de secado autombticoNormal Modificadores del ciclo de secado autombtico Ciclos programados Timed CyclesSecado expreso Express DRY TM Ajustes prefijados de ciclos programadosTipo de carga Tiempo Serial de semi seco Damp Dry SignalSerial de ciclo Cycle Signal Secado al aim Air DryCbmo cambiar los ajustes prefijados de nivel de sequedad Cambio de ciclos despu6s de presionar Inicio StartLimpieza segun la necesidad Limpieza de cada cargaPara limpiar ImportanteCuidado durante las vacaciones o falta de uso Para limpiar el tambor de la secadoraEn el interior del gabinete de la secadora En el ducto de escapeSin calor Solucion DE ProblemasCbdigos de servicio tcnico variables F1, F2, F20, etc La secadora muestra mensajes codificadosPF corte de corriente, revise Io siguiente Intente Io siguientePelusa en la ropa El tiempo del ciclo es demasiado cortoRopa arrugada Se esta usando la secadora por primera vez? OloresW10164636A Your Home