Kenmore I10.8809 If using an existing vent system, If this is a new vent system Vent material

Page 13

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

IMPORTANT: Observe all governing codes and ordinances.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible heavy metal vent.

Review Vent system chart. Modify existing vent system if necessary to achieve the best drying performance.

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE TM venting products are recommended.

Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow and poor performance.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

Elbows

45 ° elbows provide better airflow than 90 ° elbows.

9

GoodBetter

Clamps

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws or other fastening devices that extend into the interior of the duct. Do not use duct tape.

Clamp

Exhaust

Recommended hood styles are shown here.

B

(10.2 cm)

A. Louvered hood style

B. Box hood style

The angled hood style (shown here) is acceptable.

4" (10.2cm) heavymetal exhaust vent

DURASAFE TM vent products can be purchased from your dealer. For further information, please call

1-8O0-4-MY-HOME ® (1-800-469-4663} or visit our website at www.sears.com or www.sears.ca,

Rigid metal vent

For best drying performance, rigid metal vents are recommended.

Rigid metal vent is recommended to avoid crushing and kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for cleaning.

Flexible metal vent must be fully extended and supported when the dryer is in its final location.

('°

(6.4 cm)

An exhaust hood should cap the vent to keep rodents and insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, snow line, etc.).

Do not use an exhaust hood with a magnetic latch.

Improper venting can cause moisture and lint to collect indoors, which may result in:

[] Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

[] Housecleaning problems and health problems.

13

Image 13
Contents Electric Dryer Table of Contents ONE Year Limited Warranty Kenmore Elite Appliance WarrantyProtection Agreements Master Protection AgreementsYour safety and the safety of others are very important Dryer SafetyParts supplied 80O-4-MY-HOM E If using a power supply cordParts needed You will needMobile Home Additional Installation Requirements Installation ClearancesIt is your responsibility Electrical Connection If connecting by direct wireIf your outlet looks like this Ecb ca Direct WireWire connection Power supply cord Style 2 Direct wire strain reliefWire connection Direct Wire CG F Optional 3-wire connection If this is a new vent system Vent material If using an existing vent systemExhaust Rigid metal ventSpecial provisions for mobile home installations Optional exhaust installationsDetermine vent path Vent system chartNumber Type Box or Angled G0 turns Vent Louvered Hoods Hoods Rigid MetalEc, ne ,-@se Remove the door assembly If the dryer will not start, check the following To use an Auto Dry Cycle Dryer USETo stop or pause your dryer at any time To use a Timed CycleDrying tips Cycle tipsAuto Dry Cycles Heavy Duty SteamCare Preset Cycle SettingsUltra Delicate Express DRY TMAuto Dry Cycle Modifiers Changing Modifiers and Options after pressing Start Changing the Preset Dryness Level SettingsTo use the dryer rack Dryer Care For direct-wired dryers Dryer displaying code message TroubleshootingNo heat UnusualsoundsAre fabric softener sheets blocking the grille? Is the lint screen clogged with lint?Is the exhaust vent the correct length? Has the Air Dry modifier been selected?Odors Loads are wrinkledLint on load Is the lint screen clogged? Is the dryer being used for the first time?Contratos DE Proteccion Garantia Limitada DE UN Aiio Seguridad DE LA SecadoraExclusion DE Garantias Implcitas Limitacion DE Recursos Piezas suministradas Instrucciones DE InstalacionPiezas necesarias Peligro de Explosion Si emplea un cable de suministro elctricoUsted necesitara Las instalaciones en casas rodantes necesitan Usted es responsable deConexibn elctrica Si el contacto de pared luce como steSi hace la conexi6n con cableado directo Si el contacto de pared luce come steCable de suministro elctrico Cable directo Con Estilo 2 Protector de cables para cable directoConexibn de 4 hilos Cable de suministro elctrico Conexibn de 4 hilos Cable directo CG F Conexibn opcional de 3 hilos Codos Ducto de escape de metal flexibleAbrazaderas Ventilaci6nPeligro de Incendio Instalaciones opcionales de escapeDe 90 o Caja o tipo Codos Persiana No. de Tipo de ducto Capotas de Vueltas Ventilaci6n deDeterminacibn de la via del ducto de escape Cuadro del sistema de ventilacibnRe& c de C6mo invertir el tope Si la secadora no funciona, revise Io siguiente Peligro de Explosi6n USO DE LA SecadoraSistema de secado de doble acci6n Para usar un ciclo de secado automatico Auto Dry Cycle Para hacer cambios durante un ciclo de secado automaticoPara usar un Ciclo con vapor SteamOare Cycle Para usar un ciclo programadoSugerencias de secado Para reanudar la marcha de la secadoraSugerencias de ciclos Mojado WetTowels Ciclos de secado autombticoNormal Secado expreso Express DRY TM Ciclos programados Timed CyclesAjustes prefijados de ciclos programados Modificadores del ciclo de secado autombticoSerial de ciclo Cycle Signal Serial de semi seco Damp Dry SignalSecado al aim Air Dry Tipo de carga TiempoCbmo cambiar los ajustes prefijados de nivel de sequedad Cambio de ciclos despu6s de presionar Inicio StartPara limpiar Limpieza de cada cargaImportante Limpieza segun la necesidadEn el interior del gabinete de la secadora Para limpiar el tambor de la secadoraEn el ducto de escape Cuidado durante las vacaciones o falta de usoSin calor Solucion DE ProblemasPF corte de corriente, revise Io siguiente La secadora muestra mensajes codificadosIntente Io siguiente Cbdigos de servicio tcnico variables F1, F2, F20, etcPelusa en la ropa El tiempo del ciclo es demasiado cortoRopa arrugada Se esta usando la secadora por primera vez? OloresW10164636A Your Home