Kenmore I10.8808, I10.8809 manual For direct-wired dryers

Page 26

From Inside the Dryer Cabinet

Lint should be removed every 2 years, or more often, depending on dryer usage. Cleaning should be done by a qualified person.

From the Exhaust Vent

Lint should be removed every 2 years, or more often, depending on dryer usage.

Replace inlet hoses and hose screen after 5 years of use to reduce the risk of hose failure. Periodically inspect and replace inlet hoses if bulges, kinks, cuts, wear or leaks are found.

When replacing your inlet hoses, record the date of replacement.

"_ "+_]I, '

¢;@, ...... 'I

'<"+.t,

,

"*

....

i

Install and store your dryer where it will not freeze, Because some water may stay in the hoses, freezing can damage your dryer. If storing or moving your dryer during freezing weather, winterize it.

Non-Use or Vacation Care

Operate your dryer only when you are at home. If you will be on vacation or not using your dryer for an extended period of time, you should:

1.Unplug dryer or disconnect power.

2.Clean lint screen. See "Cleaning the Lint Screen."

3.Turn off the water supply to the dryer. This helps to avoid unintended flooding (due to a water pressure surge) while you are away.

To winterize dryer

1.Unplug dryer or disconnect power.

2.Shut off water faucet.

3.Disconnect water inlet hose from faucet and drain.

To use dryer again

1.Flush water pipes. Reconnect water inlet hose to faucet. Turn on water faucet.

2.Plug in dryer or reconnect power.

Moving care

For power supply cord-connected dryers:

1.Unplug the power supply cord.

2.Shut off water faucet.

3.Disconnect the water inlet hose from faucet, then drain the hose. Transport hose separately.

4.Make sure leveling legs are secure in dryer base.

5.Use masking tape to secure dryer door.

For direct-wired dryers:

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

1.Disconnect power.

2.Disconnect wiring.

3.Shut off water faucet.

4.Disconnect the water inlet hose from faucet, then drain the hose. Transport hose separately.

5.Make sure leveling legs are secure in dryer base.

6.Use masking tape to secure dryer door.

Reinstalling the dryer

Follow the "Installation Instructions" to locate, level and connect the dryer.

The dryer light automatically turns on inside the dryer drum when

you open the door.

To change the drum light

1.Unplug dryer or disconnect power.

2.Open the dryer door. Locate the light bulb cover on the back wall of the dryer. Remove the screw located in the lower right corner of the cover. Remove the cover.

3.Turn bulb counterclockwise. Replace the bulb with a 10-watt appliance bulb only. Replace the cover and secure with the screw.

4.Plug in dryer or reconnect power.

26

Image 26
Contents Electric Dryer Table of Contents Protection Agreements Kenmore Elite Appliance WarrantyONE Year Limited Warranty Master Protection AgreementsDryer Safety Your safety and the safety of others are very importantParts needed 80O-4-MY-HOM E If using a power supply cordParts supplied You will needIt is your responsibility Installation ClearancesMobile Home Additional Installation Requirements If your outlet looks like this If connecting by direct wireElectrical Connection Direct Wire Ecb caStyle 2 Direct wire strain relief Wire connection Power supply cordWire connection Direct Wire CG F Optional 3-wire connection Exhaust If using an existing vent systemIf this is a new vent system Vent material Rigid metal ventOptional exhaust installations Special provisions for mobile home installationsNumber Type Box or Angled G0 turns Vent Louvered Hoods Vent system chartDetermine vent path Hoods Rigid MetalEc, ne ,-@se Remove the door assembly If the dryer will not start, check the following Dryer USE To use an Auto Dry CycleDrying tips To use a Timed CycleTo stop or pause your dryer at any time Cycle tipsAuto Dry Cycles Ultra Delicate SteamCare Preset Cycle SettingsHeavy Duty Express DRY TMAuto Dry Cycle Modifiers To use the dryer rack Changing the Preset Dryness Level SettingsChanging Modifiers and Options after pressing Start Dryer Care For direct-wired dryers No heat TroubleshootingDryer displaying code message UnusualsoundsIs the exhaust vent the correct length? Is the lint screen clogged with lint?Are fabric softener sheets blocking the grille? Has the Air Dry modifier been selected?Lint on load Is the lint screen clogged? Loads are wrinkledOdors Is the dryer being used for the first time?Contratos DE Proteccion Exclusion DE Garantias Implcitas Limitacion DE Recursos Seguridad DE LA SecadoraGarantia Limitada DE UN Aiio Piezas necesarias Instrucciones DE InstalacionPiezas suministradas Usted necesitara Si emplea un cable de suministro elctricoPeligro de Explosion Conexibn elctrica Usted es responsable deLas instalaciones en casas rodantes necesitan Si el contacto de pared luce como steSi el contacto de pared luce come ste Si hace la conexi6n con cableado directoCable de suministro elctrico Cable directo Conexibn de 4 hilos Cable de suministro elctrico Estilo 2 Protector de cables para cable directoCon Conexibn de 4 hilos Cable directo CG F Conexibn opcional de 3 hilos Abrazaderas Ducto de escape de metal flexibleCodos Ventilaci6nInstalaciones opcionales de escape Peligro de IncendioDeterminacibn de la via del ducto de escape No. de Tipo de ducto Capotas de Vueltas Ventilaci6n deDe 90 o Caja o tipo Codos Persiana Cuadro del sistema de ventilacibnRe& c de C6mo invertir el tope Si la secadora no funciona, revise Io siguiente Sistema de secado de doble acci6n USO DE LA SecadoraPeligro de Explosi6n Para usar un Ciclo con vapor SteamOare Cycle Para hacer cambios durante un ciclo de secado automaticoPara usar un ciclo de secado automatico Auto Dry Cycle Para usar un ciclo programadoSugerencias de ciclos Para reanudar la marcha de la secadoraSugerencias de secado Mojado WetNormal Ciclos de secado autombticoTowels Ajustes prefijados de ciclos programados Ciclos programados Timed CyclesSecado expreso Express DRY TM Modificadores del ciclo de secado autombticoSecado al aim Air Dry Serial de semi seco Damp Dry SignalSerial de ciclo Cycle Signal Tipo de carga TiempoCambio de ciclos despu6s de presionar Inicio Start Cbmo cambiar los ajustes prefijados de nivel de sequedadImportante Limpieza de cada cargaPara limpiar Limpieza segun la necesidadEn el ducto de escape Para limpiar el tambor de la secadoraEn el interior del gabinete de la secadora Cuidado durante las vacaciones o falta de usoSolucion DE Problemas Sin calorIntente Io siguiente La secadora muestra mensajes codificadosPF corte de corriente, revise Io siguiente Cbdigos de servicio tcnico variables F1, F2, F20, etcRopa arrugada El tiempo del ciclo es demasiado cortoPelusa en la ropa Olores Se esta usando la secadora por primera vez?Your Home W10164636A