GSI Outdoors PNEG-951 Control Power Switch, Drying Mode Switch, Load Auger Switch, FAN Switch

Page 19

CONTROL POWER SWITCH

The control power to energize the Network Control System is turned on or off with this switch.

Note: This switch does not disconnect the power that is present at the breakers, contactors, transformer(s), fuses or other electrical components found in the upper and lower control boxes. Turn the Main Disconnect Handle to the OFF posistion prior to servicing any of the installed components.

DRYING MODE SWITCH

This is used to select staged batch or continuous flow drying. The switch will light only after the Network Control

System has been turned on, the safety circuit is okay and the

button on the control panel has been

pressed.

 

LOAD AUGER SWITCH

This is used to select the operation of the fill auger. In both the auto and manual position the load auger will operate if the dryer is low on grain and will automatically shut off when the dryer is full. In the auto position only, the dryer will shut down after a preset period of time set on the out of grain timer, or if grain flow is interrupted to the dryer. The switch will light whenever the load auger is operating.

Note: If the load auxiliary controls are being used, this switch will also control the operation of the auxil- iary equipment.

FAN SWITCH

Each fan is turned on or off with this switch. The on position operates the fan continuously during staged batch and continuous flow modes. The auto position operates the fan in staged batch during the dry and cool cycle but the fan will not operate during the unload cycle. The switch will light up whenever the air pressure switch is sensing air pressure and the dryer is full of grain.

Note: The bottom fan on your dryer is always Fan 1.

HEATER SWITCH

Each burner is turned on or off with this switch. The auto position operates the burner in staged batch during the dry cycle only. The on position will operate the burner only when the fan is running. The switch will light up only when the flame sensor detects the flame.

Note: The bottom burner on your dryer is always Burner 1.

UNLOAD SWITCH

The unload switch turns the metering rolls and discharge auger on or off, and selects the operation of the metering rolls.

In the 2 speed position if the moisture control switch is on, and the drying mode switch is turned to cont. flow, the metering roll speed will alternate between the high speed metering roll potentiometer setting and the low speed metering roll potentiometer setting depending on whether the grain temperature is above or below the grain temperature setpoint. The discharge auger will operate continuously.

In the 1 speed position, if the moisture control switch is on, and the drying mode switch is turned to cont. flow, the metering roll speed will discharge grain at the high speed metering roll potentiometer setting or turn off the meter rolls depending on whether the grain temperature is above or below the grain temperature setpoint. The discharge auger will operate whenever the metering rolls are operating.

In both the 1 speed or the 2 speed position, if the moisture control switch is off, and the drying mode switch is turned to cont. flow, the metering roll speed can be manually controlled by adjusting the high speed metering roll potentiometer. The discharge auger will operate continuously.

If the drying mode switch is turned to staged batch, the unload switch should be set to the 1 speed position. The discharge auger and metering rolls will only operate during the unload cycle of the staged batch operation, and the speed of the metering rolls is adjusted using the high speed metering roll potentiometer.

Note: If the unload auxiliary controls are being used, this switch will also control the operation of the auxiliary equipment.

PNEG-951

19

Image 19
Contents 3 Module Network Portable Dryer Models Page Table of Contents Drying Charts Module Network Dryer Manual Introduction Section GSI GROUP, INC. Warranty Safety First Dryer Operation Decal DC-889 Decal DC-972 Decal DC-1227 Decal DC-973 USE Caution in the Operation of this Equipment PNEG-951 Control Panel Switch Panel Layout FAN Switch Control Power SwitchDrying Mode Switch Load Auger SwitchStop Switch Moisture Control SwitchOutside Light Switch RUN SwitchSetup Button Screens Button Delay ButtonOut of Grain Time Set Out of Grain Meter Roll SP Avg View Grain TempsUser Hour Meter Unload Button Help ButtonDRY Button Cool ButtonStats Button PNEG-951 Dryer Pre Season Checks Fuel Check Electrical PowerInspect the Metering Rolls RUN ButtonMetering Roll Operation Load AugerUnload ONE Speed Operation Unload TWO Speed OperationMeter Roll 2 Speed Display FAN SwitchesBurner Safety Burner Test FireEmergency Dryer Shutdown Dryer ShutdownPNEG-951 Dryer Startup and Operation Dryer Shutdown Initial Setup ParametersTimer and Delay Settings Fan and Auger DelaysLoad Delay OUT of Grain TMR position Unload Delay Drying mode switch is in the Continuous position Setting Up The Temperature Set PointsStartup Startup ProcedureFull Heat-Continuous Flow Operation Continuous Flow Drying ModeDry and Cool-Continuous Flow Operation Continuous-Batch Operation Staged Batch Drying ModePNEG-951 Dry Timer Main Display Screen Operating Display ScreensPNEG-951 Safety Circuit Shutdown Messages Fan x No Airflow FAN and Heater Generated ErrorsAir Switch x Stuck Fan x Loss of AirflowIgnition Failure Housing x High LimitGrain Temp Short Grain x OverheatPlenum Temp Short Illegal FlameMotor Overload Plenum Temp OpenAux Load Overload INPUT/OUTPUT Generated ErrorsVapor x High Limit Air System FailureOut of Grain Grain Discharge WarningLoad Motor Overload Meter Rolls FailedUnload Motor Overload Master Display Generated ErrorsUser Safety Cont-Batch Mode ChngNetwork Failed Mast Network Failed I/OService and Maintanance Lubrication Procedure Seasonal Inspection and ServiceFAN Blade Removal and Installation FAN Removaland Installation FAN Motor Removal Heater Parts Removal and InstallationMain Controls Meter Roll ServicingHOW to Clear a Jammed Metering Roll Trouble Analysis Procedure PNEG-951 PNEG-951 PNEG-951 PNEG-951 Special Setup Screens AIR Switch Testing Meter Roll DisableMeter Roll Reverse Select Unload Method Reverse timeAttempt to Refill Select Dryer AddressModel Number FAN/HEATER Select Temperature ScaleSET Time & Date Possible reasons for using On/Off burnerContrast Adjustment PNEG-951 Drying Charts Series Dryers Continuous Dry & Cool Staged Batch Continuous Full Heat Continuous Dry & Cool Staged Batch PNEG-951 Technical Reference Control Panel Jumper Wiring Control Panel Internal Wiring PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 Lower Control BOX Back Panelwiring Network FAN/HEATER Interface FAN Computer Pinouts FAN Control BOX Upper Terminal Strip Upper Back Panel Control Wiring 100 PNEG-951 PNEG-951 101 GSI Group, Inc 1004 E. Illinois St Assumption, IL Phone Fax