GSI Outdoors PNEG-951 manual Dry Timer

Page 46

During operation the remaining time on each timer is displayed on the screen. If the power goes out or if the dryer is stopped, these times are saved by the controller. When the dryer is restarted the timers will continue timing down. The timers will return to their initial setting if the reset button is pushed.

Use the dryer charts in the back of this manual for reference of a suggested timer settings.

Dry Timer

This timer controls how long the burner will operate. If the moisture control switch is turned on and the dry time reaches zero, then the burner will continue to burn as long as the grain temperature has not reached the moisture control set point.

To change the setting of this timer follow these instructions:

Press the

timer button, press the

button to edit the amount of dry time.

Press the

button to adjust the dry timer settings.

Press the

button to accept the new setting.

During dryer operation the remaining time on each timer is displayed on the screen unless reset to their

stored values by pressing the

button.

Cool Timer

This timer controls how long the fan will operate after the dry timer has expired.

To change the setting of this timer follow these instructions:

Press the

timer button, press the

button to edit the amount of cool time.

Press the

button to adjust the settings.

Press the

button to accept the new setting.

During dryer operation the remaining time on each timer is displayed on the screen unless reset to their

stored values by pressing the

button.

46

PNEG-951

Image 46
Contents 3 Module Network Portable Dryer Models Page Table of Contents Drying Charts Module Network Dryer Manual Introduction Section GSI GROUP, INC. Warranty Safety First Dryer Operation Decal DC-889 Decal DC-972 Decal DC-1227 Decal DC-973 USE Caution in the Operation of this Equipment PNEG-951 Control Panel Switch Panel Layout Load Auger Switch Control Power SwitchDrying Mode Switch FAN SwitchRUN Switch Moisture Control SwitchOutside Light Switch Stop SwitchSetup Button Screens Button Delay ButtonOut of Grain Time Set Out of Grain View Grain Temps Meter Roll SP AvgUser Hour Meter Cool Button Help ButtonDRY Button Unload ButtonStats Button PNEG-951 Dryer Pre Season Checks RUN Button Electrical PowerInspect the Metering Rolls Fuel CheckUnload TWO Speed Operation Load AugerUnload ONE Speed Operation Metering Roll OperationBurner Test Fire FAN SwitchesBurner Safety Meter Roll 2 Speed DisplayDryer Shutdown Emergency Dryer ShutdownPNEG-951 Dryer Startup and Operation Fan and Auger Delays Initial Setup ParametersTimer and Delay Settings Dryer ShutdownLoad Delay OUT of Grain TMR position Unload Delay Setting Up The Temperature Set Points Drying mode switch is in the Continuous positionStartup Procedure StartupContinuous Flow Drying Mode Full Heat-Continuous Flow OperationDry and Cool-Continuous Flow Operation Staged Batch Drying Mode Continuous-Batch OperationPNEG-951 Dry Timer Operating Display Screens Main Display ScreenPNEG-951 Safety Circuit Shutdown Messages Fan x Loss of Airflow FAN and Heater Generated ErrorsAir Switch x Stuck Fan x No AirflowGrain x Overheat Housing x High LimitGrain Temp Short Ignition FailurePlenum Temp Open Illegal FlameMotor Overload Plenum Temp ShortAir System Failure INPUT/OUTPUT Generated ErrorsVapor x High Limit Aux Load OverloadMeter Rolls Failed Grain Discharge WarningLoad Motor Overload Out of GrainCont-Batch Mode Chng Master Display Generated ErrorsUser Safety Unload Motor OverloadNetwork Failed I/O Network Failed MastService and Maintanance Seasonal Inspection and Service Lubrication ProcedureFAN Blade Removal and Installation FAN Removaland Installation Heater Parts Removal and Installation FAN Motor RemovalMeter Roll Servicing Main ControlsHOW to Clear a Jammed Metering Roll Trouble Analysis Procedure PNEG-951 PNEG-951 PNEG-951 PNEG-951 Special Setup Screens AIR Switch Testing Meter Roll DisableMeter Roll Reverse Reverse time Select Unload MethodAttempt to Refill Select Dryer AddressModel Number Temperature Scale FAN/HEATER SelectPossible reasons for using On/Off burner SET Time & DateContrast Adjustment PNEG-951 Drying Charts Series Dryers Continuous Dry & Cool Staged Batch Continuous Full Heat Continuous Dry & Cool Staged Batch PNEG-951 Technical Reference Control Panel Jumper Wiring Control Panel Internal Wiring PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 Lower Control BOX Back Panelwiring Network FAN/HEATER Interface FAN Computer Pinouts FAN Control BOX Upper Terminal Strip Upper Back Panel Control Wiring 100 PNEG-951 PNEG-951 101 GSI Group, Inc 1004 E. Illinois St Assumption, IL Phone Fax