GSI Outdoors PNEG-951 manual Dry and Cool-Continuous Flow Operation

Page 43

12.Run the fan(s) and heater(s) for about 10% longer than the (APPROX. DRYING TIME) required for the moisture you are trying to dry.

13.Example: 10% removal would be about 54 minutes, 15% removal would be about 76 minutes and 20% removal would be about 100 minutes. Add 10 minutes to insure that the grain is dry.

14.After the time in step 12 turn the UNLOAD to 1 SPEED and set the METER ROLL SPEED, (HIGH SPEED). to the setting for 1 SPEED operation. Grain should begin to run at this time. Run time for this is about 10% longer than the (APPROX. DRYING TIME) required for the moisture you are trying to dry. This allows the moisture in the dryer to reach an even gradient top to bottom without having any highs or lows in it. It will however, over dry some of the corn a little.

15.Increase the drying temperature to 190 deg. for single fans or for multiple fan dryers set the heat cham- bers 30 to 60 degrees apart. Hottest at the top, most cool at the bottom.

16.DO NOT TRY TO ADJUST THE DRYER FOR MOISTURE DURING THIS PROCESS OR YOU WILL ESTABLISH HIGH AND LOW SWINGS IN THE MOISTURE CONTROL. IT WILL TAKE SEVERAL HOURS TO WORK ITSELF OUT.

17.After the run time in step 14 you are ready to set up the moisture control. Now turn the MOISTURE CONTROL to the ON position. Set the temperature to about 100 deg.

18.Turn the UNLOAD to 2 SPEED. Set the METER ROLL SPEED, LOW SPEED and HIGH SPEED. to the settings listed for them. Let the dryer run on these settings before trying to adjust moisture or meter roll settings. These settings will not have your grain moisture adjusted exactly where you want it, but will be a good place to start initially. A little different moisture at the bottom of the storage bin is not usually a problem as long as you have full floor aeration.

19.After the run time in step 18 you are ready to adjust the moisture control, and the meter roll speeds if required. Each time you make an adjustment to the moisture control it will take about the time shown in the drying charts to see the results of this adjustment.

Dry and Cool-Continuous Flow Operation

1. Turn the control power switch to on.

2. After the date and time appear on screen, press the

button.

3.Turn the DRYING MODE switch to CONT. FLOW.

4.Make sure the UNLOAD switch is OFF.

5.Make sure the MOISTURE CONTROL switch is OFF.

6.Open the main fuel supply valve on the tank if using LP gas, or open the fuel supply line if using natural gas. Turn on the Maxon electric shut off valve, if so equipped, or open the manual shut off valve to allow fuel flow to the dryer.

7.Push the DRYER POWER START switch.

8.The dryer should already be filled with grain. Turn the LOAD AUGER switch to the AUTO position. In both the auto and manual positions, the dryer grain level switch will automatically keep the dryer full of grain. In the auto position the dryer will shut down after a preset time period on the out of grain timer.

PNEG-951

43

Image 43
Contents 3 Module Network Portable Dryer Models Page Table of Contents Drying Charts Module Network Dryer Manual Introduction Section GSI GROUP, INC. Warranty Safety First Dryer Operation Decal DC-889 Decal DC-972 Decal DC-1227 Decal DC-973 USE Caution in the Operation of this Equipment PNEG-951 Control Panel Switch Panel Layout FAN Switch Control Power SwitchDrying Mode Switch Load Auger SwitchStop Switch Moisture Control SwitchOutside Light Switch RUN SwitchSetup Button Screens Button Delay ButtonOut of Grain Time Set Out of Grain Meter Roll SP Avg View Grain TempsUser Hour Meter Unload Button Help ButtonDRY Button Cool ButtonStats Button PNEG-951 Dryer Pre Season Checks Fuel Check Electrical PowerInspect the Metering Rolls RUN ButtonMetering Roll Operation Load AugerUnload ONE Speed Operation Unload TWO Speed OperationMeter Roll 2 Speed Display FAN SwitchesBurner Safety Burner Test FireEmergency Dryer Shutdown Dryer ShutdownPNEG-951 Dryer Startup and Operation Dryer Shutdown Initial Setup ParametersTimer and Delay Settings Fan and Auger DelaysLoad Delay OUT of Grain TMR position Unload Delay Drying mode switch is in the Continuous position Setting Up The Temperature Set PointsStartup Startup ProcedureFull Heat-Continuous Flow Operation Continuous Flow Drying ModeDry and Cool-Continuous Flow Operation Continuous-Batch Operation Staged Batch Drying ModePNEG-951 Dry Timer Main Display Screen Operating Display ScreensPNEG-951 Safety Circuit Shutdown Messages Fan x No Airflow FAN and Heater Generated ErrorsAir Switch x Stuck Fan x Loss of AirflowIgnition Failure Housing x High LimitGrain Temp Short Grain x OverheatPlenum Temp Short Illegal FlameMotor Overload Plenum Temp OpenAux Load Overload INPUT/OUTPUT Generated ErrorsVapor x High Limit Air System FailureOut of Grain Grain Discharge WarningLoad Motor Overload Meter Rolls FailedUnload Motor Overload Master Display Generated ErrorsUser Safety Cont-Batch Mode ChngNetwork Failed Mast Network Failed I/OService and Maintanance Lubrication Procedure Seasonal Inspection and ServiceFAN Blade Removal and Installation FAN Removaland Installation FAN Motor Removal Heater Parts Removal and InstallationMain Controls Meter Roll ServicingHOW to Clear a Jammed Metering Roll Trouble Analysis Procedure PNEG-951 PNEG-951 PNEG-951 PNEG-951 Special Setup Screens AIR Switch Testing Meter Roll DisableMeter Roll Reverse Select Unload Method Reverse timeAttempt to Refill Select Dryer AddressModel Number FAN/HEATER Select Temperature ScaleSET Time & Date Possible reasons for using On/Off burnerContrast Adjustment PNEG-951 Drying Charts Series Dryers Continuous Dry & Cool Staged Batch Continuous Full Heat Continuous Dry & Cool Staged Batch PNEG-951 Technical Reference Control Panel Jumper Wiring Control Panel Internal Wiring PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 Lower Control BOX Back Panelwiring Network FAN/HEATER Interface FAN Computer Pinouts FAN Control BOX Upper Terminal Strip Upper Back Panel Control Wiring 100 PNEG-951 PNEG-951 101 GSI Group, Inc 1004 E. Illinois St Assumption, IL Phone Fax