GSI Outdoors PNEG-951 manual Drying Charts

Page 4

 

Meter Roll Reverse

70

 

Select Unload Method

71

 

Select Dryer Address

72

 

Attempt to Refill

72

 

Model Number

72

 

Temperature Scale

73

 

Fan/Heater Select

73

 

Set Time & Date

74

 

Contrast Adjustment

75

Section 9

Drying Charts

77

 

2000 Series

78

 

3000 Series

81

Section 10

Technical Reference

85

 

2 Fan Control Panel Wiring

86

 

3 Fan Control Panel Wiring

88

 

4 Fan Control Panel Wiring

90

 

6 Fan Control Panel Wiring

92

 

Lower Control Box Back Panel Wiring

94

 

Network Fan/Heater Interface

95

 

Fan Computer Pinouts

96

 

Fan Can Control Box

97

 

Upper Terminal Strip

98

 

Upper Control Back Panel Wiring

99

4

PNEG-951

Image 4
Contents 3 Module Network Portable Dryer Models Page Table of Contents Drying Charts Module Network Dryer Manual Introduction Section GSI GROUP, INC. Warranty Safety First Dryer Operation Decal DC-889 Decal DC-972 Decal DC-1227 Decal DC-973 USE Caution in the Operation of this Equipment PNEG-951 Control Panel Switch Panel Layout Control Power Switch Drying Mode SwitchLoad Auger Switch FAN SwitchMoisture Control Switch Outside Light SwitchRUN Switch Stop SwitchSetup Button Screens Button Delay ButtonOut of Grain Time Set Out of Grain View Grain Temps Meter Roll SP AvgUser Hour Meter Help Button DRY ButtonCool Button Unload ButtonStats Button PNEG-951 Dryer Pre Season Checks Electrical Power Inspect the Metering RollsRUN Button Fuel CheckLoad Auger Unload ONE Speed OperationUnload TWO Speed Operation Metering Roll OperationFAN Switches Burner SafetyBurner Test Fire Meter Roll 2 Speed DisplayDryer Shutdown Emergency Dryer ShutdownPNEG-951 Dryer Startup and Operation Initial Setup Parameters Timer and Delay SettingsFan and Auger Delays Dryer ShutdownLoad Delay OUT of Grain TMR position Unload Delay Setting Up The Temperature Set Points Drying mode switch is in the Continuous positionStartup Procedure StartupContinuous Flow Drying Mode Full Heat-Continuous Flow OperationDry and Cool-Continuous Flow Operation Staged Batch Drying Mode Continuous-Batch OperationPNEG-951 Dry Timer Operating Display Screens Main Display ScreenPNEG-951 Safety Circuit Shutdown Messages FAN and Heater Generated Errors Air Switch x StuckFan x Loss of Airflow Fan x No AirflowHousing x High Limit Grain Temp ShortGrain x Overheat Ignition FailureIllegal Flame Motor OverloadPlenum Temp Open Plenum Temp ShortINPUT/OUTPUT Generated Errors Vapor x High LimitAir System Failure Aux Load OverloadGrain Discharge Warning Load Motor OverloadMeter Rolls Failed Out of GrainMaster Display Generated Errors User SafetyCont-Batch Mode Chng Unload Motor OverloadNetwork Failed I/O Network Failed MastService and Maintanance Seasonal Inspection and Service Lubrication ProcedureFAN Blade Removal and Installation FAN Removaland Installation Heater Parts Removal and Installation FAN Motor RemovalMeter Roll Servicing Main ControlsHOW to Clear a Jammed Metering Roll Trouble Analysis Procedure PNEG-951 PNEG-951 PNEG-951 PNEG-951 Special Setup Screens AIR Switch Testing Meter Roll DisableMeter Roll Reverse Reverse time Select Unload MethodAttempt to Refill Select Dryer AddressModel Number Temperature Scale FAN/HEATER SelectPossible reasons for using On/Off burner SET Time & DateContrast Adjustment PNEG-951 Drying Charts Series Dryers Continuous Dry & Cool Staged Batch Continuous Full Heat Continuous Dry & Cool Staged Batch PNEG-951 Technical Reference Control Panel Jumper Wiring Control Panel Internal Wiring PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 Lower Control BOX Back Panelwiring Network FAN/HEATER Interface FAN Computer Pinouts FAN Control BOX Upper Terminal Strip Upper Back Panel Control Wiring 100 PNEG-951 PNEG-951 101 GSI Group, Inc 1004 E. Illinois St Assumption, IL Phone Fax