GSI Outdoors PNEG-951 manual Stats Button

Page 27

STATS BUTTON

Pressing the

button will toggle the last line of the main display screen to 3 different views

relating to the dryers approximated output rate.

This screen shows the actual turning speed of the meter rolls in RPM.

Pressing the

button again shows an approximated Bushel per hour that have passed through

the dryer using the above RPM readings as a reference. This can vary depending on the cleanliness and test weight of the grain and/or the position of the slide gates located directly above the turning metering rolls.

Pressing the

button again shows an approximated Total Bushels that have passed through the dryer

using the above RPM readings as a reference.

PNEG-951

27

Image 27
Contents 3 Module Network Portable Dryer Models Page Table of Contents Drying Charts Module Network Dryer Manual Introduction Section GSI GROUP, INC. Warranty Safety First Dryer Operation Decal DC-889 Decal DC-972 Decal DC-1227 Decal DC-973 USE Caution in the Operation of this Equipment PNEG-951 Control Panel Switch Panel Layout FAN Switch Control Power SwitchDrying Mode Switch Load Auger SwitchStop Switch Moisture Control SwitchOutside Light Switch RUN SwitchSetup Button Delay Button Screens ButtonOut of Grain Time Set Out of Grain Meter Roll SP Avg View Grain TempsUser Hour Meter Unload Button Help ButtonDRY Button Cool ButtonStats Button PNEG-951 Dryer Pre Season Checks Fuel Check Electrical PowerInspect the Metering Rolls RUN ButtonMetering Roll Operation Load AugerUnload ONE Speed Operation Unload TWO Speed OperationMeter Roll 2 Speed Display FAN SwitchesBurner Safety Burner Test FireEmergency Dryer Shutdown Dryer ShutdownPNEG-951 Dryer Startup and Operation Dryer Shutdown Initial Setup ParametersTimer and Delay Settings Fan and Auger DelaysLoad Delay OUT of Grain TMR position Unload Delay Drying mode switch is in the Continuous position Setting Up The Temperature Set PointsStartup Startup ProcedureFull Heat-Continuous Flow Operation Continuous Flow Drying ModeDry and Cool-Continuous Flow Operation Continuous-Batch Operation Staged Batch Drying ModePNEG-951 Dry Timer Main Display Screen Operating Display ScreensPNEG-951 Safety Circuit Shutdown Messages Fan x No Airflow FAN and Heater Generated ErrorsAir Switch x Stuck Fan x Loss of AirflowIgnition Failure Housing x High LimitGrain Temp Short Grain x OverheatPlenum Temp Short Illegal FlameMotor Overload Plenum Temp OpenAux Load Overload INPUT/OUTPUT Generated ErrorsVapor x High Limit Air System FailureOut of Grain Grain Discharge WarningLoad Motor Overload Meter Rolls FailedUnload Motor Overload Master Display Generated ErrorsUser Safety Cont-Batch Mode ChngNetwork Failed Mast Network Failed I/OService and Maintanance Lubrication Procedure Seasonal Inspection and ServiceFAN Blade Removal and Installation FAN Removaland Installation FAN Motor Removal Heater Parts Removal and InstallationMain Controls Meter Roll ServicingHOW to Clear a Jammed Metering Roll Trouble Analysis Procedure PNEG-951 PNEG-951 PNEG-951 PNEG-951 Special Setup Screens Meter Roll Disable AIR Switch TestingMeter Roll Reverse Select Unload Method Reverse timeSelect Dryer Address Attempt to RefillModel Number FAN/HEATER Select Temperature ScaleSET Time & Date Possible reasons for using On/Off burnerContrast Adjustment PNEG-951 Drying Charts Series Dryers Continuous Dry & Cool Staged Batch Continuous Full Heat Continuous Dry & Cool Staged Batch PNEG-951 Technical Reference Control Panel Jumper Wiring Control Panel Internal Wiring PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 Lower Control BOX Back Panelwiring Network FAN/HEATER Interface FAN Computer Pinouts FAN Control BOX Upper Terminal Strip Upper Back Panel Control Wiring 100 PNEG-951 PNEG-951 101 GSI Group, Inc 1004 E. Illinois St Assumption, IL Phone Fax