This section gives a series of checks to be carried out on the dryer before starting for the first time in the drying season. If any of the checks fail to produce the stated result, you should consult your dealer.

YOU SHOULD NOT ATTEMPT TO USE THE DRYER UNLESS ALL THE PRE-START CHECKS HAVE BEEN SUCCESSFULLY COMPLETED.

BEFORE ATTEMPTING TO OPERATE THE DRYER MAKE SURE ALL SAFETY SHIELDS ARE IN PLACE, ALL BOTTOM CLEANOUT AND REAR ACCESS DOORS ARE CLOSED AND ALL PERSONNEL ARE CLEAR OF THE DRYER

INSPECT THE METERING ROLLS

Open all metering roll access doors and inspect each compartment for any bolts, nuts or other foreign material, that may cause possible jamming of the metering rolls.

ELECTRICAL POWER

Turn on the electrical power supply to the dryer, set all circuit breakers to on, including the safety disconnect handle mounted on front of the dryer power panel.

CONTROL POWER SWITCH

Turn the control power switch to on. The switch will light up. A copyright message, model number, total running time in hours and minutes, current date and time will appear. At this point the controller will lock out all other dryer

functions. Once the date and time appear, press the

button and the dryer will perform a safety circuit

check. If a fault is found, the cause will be displayed on the LCD. If all are found safe, the controller will supply power to the electronic fuel shut-off valve (Maxon), if so equipped, and the drying mode switch will light up, indicat- ing that the dryer is ready to be started.

RUN BUTTON

Push the dryer run button, and all the selector switches on the control panel will be activated.

FUEL CHECK

If using LP gas, make sure the tank has plenty of fuel and that the tank must not have a regulator mounted on the liquid line. Slowly open the main fuel supply valve at the tank. Then, open the electronic shut off valve (Maxon valve), if so equipped, or open the manual shut off valve on the dryer to allow fuel flow to the dryer.

If using natural gas, make sure an adequate supply is available. Turn on the valve along the supply line. Then, open the electronic shut off valve (Maxon valve). Inspect all gas lines and connections for possible leaks.

Any gas leaks must be fixed immediately!

30

PNEG-951

Image 30
Contents 3 Module Network Portable Dryer Models Page Table of Contents Drying Charts Module Network Dryer Manual Introduction Section GSI GROUP, INC. Warranty Safety First Dryer Operation Decal DC-889 Decal DC-972 Decal DC-1227 Decal DC-973 USE Caution in the Operation of this Equipment PNEG-951 Control Panel Switch Panel Layout Load Auger Switch Control Power SwitchDrying Mode Switch FAN SwitchRUN Switch Moisture Control SwitchOutside Light Switch Stop SwitchSetup Button Delay Button Screens ButtonOut of Grain Time Set Out of Grain View Grain Temps Meter Roll SP AvgUser Hour Meter Cool Button Help ButtonDRY Button Unload ButtonStats Button PNEG-951 Dryer Pre Season Checks RUN Button Electrical PowerInspect the Metering Rolls Fuel CheckUnload TWO Speed Operation Load AugerUnload ONE Speed Operation Metering Roll OperationBurner Test Fire FAN SwitchesBurner Safety Meter Roll 2 Speed DisplayDryer Shutdown Emergency Dryer ShutdownPNEG-951 Dryer Startup and Operation Fan and Auger Delays Initial Setup ParametersTimer and Delay Settings Dryer ShutdownLoad Delay OUT of Grain TMR position Unload Delay Setting Up The Temperature Set Points Drying mode switch is in the Continuous positionStartup Procedure StartupContinuous Flow Drying Mode Full Heat-Continuous Flow OperationDry and Cool-Continuous Flow Operation Staged Batch Drying Mode Continuous-Batch OperationPNEG-951 Dry Timer Operating Display Screens Main Display ScreenPNEG-951 Safety Circuit Shutdown Messages Fan x Loss of Airflow FAN and Heater Generated ErrorsAir Switch x Stuck Fan x No AirflowGrain x Overheat Housing x High LimitGrain Temp Short Ignition FailurePlenum Temp Open Illegal FlameMotor Overload Plenum Temp ShortAir System Failure INPUT/OUTPUT Generated ErrorsVapor x High Limit Aux Load OverloadMeter Rolls Failed Grain Discharge WarningLoad Motor Overload Out of GrainCont-Batch Mode Chng Master Display Generated ErrorsUser Safety Unload Motor OverloadNetwork Failed I/O Network Failed MastService and Maintanance Seasonal Inspection and Service Lubrication ProcedureFAN Blade Removal and Installation FAN Removaland Installation Heater Parts Removal and Installation FAN Motor RemovalMeter Roll Servicing Main ControlsHOW to Clear a Jammed Metering Roll Trouble Analysis Procedure PNEG-951 PNEG-951 PNEG-951 PNEG-951 Special Setup Screens Meter Roll Disable AIR Switch TestingMeter Roll Reverse Reverse time Select Unload MethodSelect Dryer Address Attempt to RefillModel Number Temperature Scale FAN/HEATER SelectPossible reasons for using On/Off burner SET Time & DateContrast Adjustment PNEG-951 Drying Charts Series Dryers Continuous Dry & Cool Staged Batch Continuous Full Heat Continuous Dry & Cool Staged Batch PNEG-951 Technical Reference Control Panel Jumper Wiring Control Panel Internal Wiring PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 PNEG-951 Lower Control BOX Back Panelwiring Network FAN/HEATER Interface FAN Computer Pinouts FAN Control BOX Upper Terminal Strip Upper Back Panel Control Wiring 100 PNEG-951 PNEG-951 101 GSI Group, Inc 1004 E. Illinois St Assumption, IL Phone Fax