| TROUBLESHOOTING | ||
|
|
|
|
|
|
| Observe all Safety Guidelines detailed throughout this manual | ||
|
| PROBLEMS | POSSIBLE CAUSE | RECOMMENDED |
|
| (SYMPTOMS) | COURSE OF ACTION | |
|
|
| ||
|
|
| ||
10. Speed does not change when | a. |
| ||
| weld current flows. Status lights | the same value. |
| |
| are solid green. | b. Possible problem with current |
| |
|
|
|
| |
|
|
| sensor electronics in power |
|
|
|
| source. Check power source man- |
|
|
|
| ual to trouble shoot current sensor |
|
|
|
| electronics. |
|
|
|
|
| |
11. | Voltmeter and/or ammeter do | a. 67 and/or 21 voltage sense leads |
| |
| not function properly even | may have intermittent or poor con- |
| |
| though status lights are solid | nections. Check. |
| |
| green. Welding may vary from |
|
| |
| normal procedure. | b. Possible problem with power |
| |
|
|
| source electronics. |
|
|
|
|
| |
12. | Purge switch on feed head does | a. Defective gas purge switch or |
| |
| not activate solenoid but trigger | feed head board. Check continuity | If all recommended possible areas of | |
| closure in MIG or pulse modes | with gas purge switch held down | ||
| does. | across J1 pins 3 and 5. Release | misadjustment have been checked | |
|
|
| purge switch and note there | and the problem persists, Contact |
|
|
| should be no continuity now. If | your local Lincoln Authorized |
|
|
| either of these fail, the problem is | Field Service Facility. |
|
|
| either in the gas purge switch or |
|
|
|
| harnessing. If no failure, replace |
|
|
|
| feed head board. |
|
|
|
|
| |
13. | Cold feed switch does not acti- | a. Defective cold feed switch or feed |
| |
| vate the motor but trigger does | head PC board. Check continuity |
| |
| in MIG or Pulse modes. LEDs | with cold feed switch held up |
| |
| are solid green on both CB and | across plug pins 3 and 4 of J1. |
| |
| feed head boards. | Release the cold inch switch and |
| |
|
|
| note that there should be no conti- |
|
|
|
| nuity now. If either of these fail, |
|
|
|
| the problem is either in the purge |
|
|
|
| switch or harnessing. If continuity |
|
|
|
| O.K., replace feed head board. |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.