| TROUBLESHOOTING | |||
|
|
|
|
|
|
| Observe all Safety Guidelines detailed throughout this manual | ||
|
| PROBLEMS | POSSIBLE CAUSE | RECOMMENDED |
|
| (SYMPTOMS) | COURSE OF ACTION | |
|
|
| ||
|
|
|
| |
4. | Tip seizes in diffuser. | a. Tip overheating due to prolonged |
| |
|
|
| or excessive high current and/or |
|
|
|
| duty cycle welding. |
|
|
|
| Note: A light application of high |
|
|
|
| temperature antiseize lubri- |
|
|
|
| cant (such as Lincoln E2067 |
|
|
|
| Graphite Grease) may be |
|
|
|
| applied to tip of threads. |
|
|
|
|
| |
5. | Unit shuts off while welding or | a. Wire feed shut down circuit |
| |
| attempting to weld, status light is | maybe electrically open. (Leads |
| |
| red/green alternating between | 570 and 572 in wire feed head. |
| |
| colors every second. Unit tries to | b. The wire drive motor may be |
| |
| recover after 30 seconds and |
| ||
| may repeat again. | overloaded. Check for mechani- |
| |
|
|
| cal restrictions in the wire feeding | If all recommended possible areas of |
|
|
| path. | misadjustment have been checked |
|
|
|
| and the problem persists, Contact |
6. | Drive roll does not turn although | a. Check for loose or broken leads | your local Lincoln Authorized | |
Field Service Facility. | ||||
arc voltage is present, and solenoid | at the wire drive motor. |
| ||
is on. Feed head and Control Box | b. Defective wire feed motor or feed |
| ||
status LEDs are both solid green. |
| |||
|
|
| head PC board. Note: With WFS |
|
|
|
| set to max control board should |
|
|
|
| supply 24 VDC to motor (leads |
|
|
|
| #550, #551). |
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.