Lincoln Electric IM613-B manual Troubleshooting

Page 38

E-4

 

TROUBLESHOOTING

E-4

 

 

 

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

PROBLEMS

POSSIBLE CAUSE

RECOMMENDED

 

 

(SYMPTOMS)

COURSE OF ACTION

 

 

 

 

 

 

 

4.

Tip seizes in diffuser.

a. Tip overheating due to prolonged

 

 

 

 

or excessive high current and/or

 

 

 

 

duty cycle welding.

 

 

 

 

Note: A light application of high

 

 

 

 

temperature antiseize lubri-

 

 

 

 

cant (such as Lincoln E2067

 

 

 

 

Graphite Grease) may be

 

 

 

 

applied to tip of threads.

 

 

 

 

 

5.

Unit shuts off while welding or

a. Wire feed shut down circuit

 

 

attempting to weld, status light is

maybe electrically open. (Leads

 

 

red/green alternating between

570 and 572 in wire feed head.

 

 

colors every second. Unit tries to

b. The wire drive motor may be

 

 

recover after 30 seconds and

 

 

may repeat again.

overloaded. Check for mechani-

 

 

 

 

cal restrictions in the wire feeding

If all recommended possible areas of

 

 

 

path.

misadjustment have been checked

 

 

 

 

and the problem persists, Contact

6.

Drive roll does not turn although

a. Check for loose or broken leads

your local Lincoln Authorized

Field Service Facility.

arc voltage is present, and solenoid

at the wire drive motor.

 

is on. Feed head and Control Box

b. Defective wire feed motor or feed

 

status LEDs are both solid green.

 

 

 

 

head PC board. Note: With WFS

 

 

 

 

set to max control board should

 

 

 

 

supply 24 VDC to motor (leads

 

 

 

 

#550, #551).

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER FEED 11

Image 38
Contents Safety Depends on You IM613-BSafety Electric Shock can kill Safety IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents P315 Series Section ESection F Installation Power FeedHanging Safety PrecautionWire Feeder to Power Source Configurations On the FloorCable Connections Work Cable Connections Selecting the Proper Gear Ratio Wire Drive Gear Ratio High or LOW SpeedChanging the Wire Drive Ratio CurrentRatio Change Procedure DIP Switch Setup Setting DIP Switches in the Control BOXSetting DIP Switches in the Wire Drive Figure A.4FAST-MATEGUN Adapter Guide Tubes Procedure to Install Drive Rolls and Guide TubesDrive Roll KIT and Guide Tube Installation GUN Connection Guidelines GUN and Cable AssembliesMagnum Guns General GuidelinesCylinder may explode if damaged Gmaw Shielding GASLifting Handle Buildup of Shielding GAS may harm health or killGeneral Panel Installation Guidelines Optional Panels for Control BOXOperation K1542-11 MX2 PanelOptional Control Box Panels Lower PanelsK1542-4 CV/Gouge PanelStd K1640-1 Dual Procedure / Memory Door Panel Optional K1542-12 MSP2 Panel OptionalControl BOX Panels -- SET UP Controls Description Control BOX -- PC Board AdjustmentsControl BOX -- Using Operating Limits Control BOX -- Setting Operating LimitsSTEP/4 Step Switch Wire Drive OperationWire Drive Settings -- External Cold Feed / GAS Purge SwitchElectrode Polarity Wire Reel Loading READI-REELS, Spools or CoilsWire Drive -- PC Board Adjustments Gear BOX RatioDrive Roll Pressure Setting Feeding Electrode and Brake AdjustmentGAS Guard Regulator Setting Making a Weld Wire Reel ChangingWire Feed Overload Protection Component Status Lights Status Light StatesStatus Light States CON’T Table C.1 Drive Roll and Guide Tube Kits AccessoriesWire Size Roll Drive Driven Solid Steel Electrode Cored ElectrodeK1543, K1544 and K1545 Input Cable Assemblies General Panel Installation GuidelinesDescription of Optional CON- Trol BOX Panels K659-1 GAS Guard Regulator Wire Spindle AdaptersK1536-1 Water Flow Sensor KIT K1649-1 Mounting Bracket HorizontalWire Drive Motor and Gearbox MaintenanceMaintenance Gun and Cable Maintenance1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideTroubleshooting Your local Lincoln Authorized Possible Cause Recommended Symptoms Course of ActionField Service Facility Troubleshooting Possible Cause Course of ActionEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Possible Cause Err 004 Err 001Err 003 Err 005Err 200 Err 020Err 100 Err 201Err 211 Err 212Wiring Diagram Power Feed 11 Wire Feeder Diagrams Wiring DiagramL10834 Power Feed Basic Course $700.00Precaucion Warnung