Lincoln Electric IM613-B manual Procedure to Install Drive Rolls and Guide Tubes

Page 16

A-8

INSTALLATION

A-8

 

 

 

WIRE FEED DRIVE ROLL KITS AND FAST-MATEGUN ADAPTER GUIDE TUBES

NOTE: The maximum rated solid and cored wire sizes and selected drive ratios are shown on the SPECIFICATIONS in the front of this section. The electrode sizes that can be fed with each drive roll and wire guide are stenciled on each part. Check the kit for proper components. Kit specifications can be found in the ACCESSORIES section.

FAST-MATEGUN ADAPTER GUIDE TUBES

Guide Tubes for Steel Wire:

The Power Feed 11 is supplied with 4 wire guide tubes which allow the I.D. of the Fast-Mategun adapter to be optimized for every wire size. The vari- ous size wire guide tubes are identified by the number of rings scribed toward one end of the tube and should be selected per the table below.

Wire Size

Number

 

of Rings

.023"-.045" (0.6-1.2mm)

1

.045"-1/16" (1.2-1.6mm)

2

1/16"-5/64" (1.6-2.0mm)

3

5/64"-7/64" (2.0-2.8mm)

4

Guide Tubes for Aluminum Wire:

For optimum aluminum wire feeding the appropriate plastic lined guide tube should be used per the table below. These must be ordered.

Part

Wire Size

Tube

Number

 

Color

S24129-1

.030"-.035" (0.8-0.9mm)

Black

 

S24129-2

.035"-3/64" (0.9-1.2mm)

Blue

S24129-3

1/16" (1.6mm)

Red

PROCEDURE TO INSTALL DRIVE ROLLS AND GUIDE TUBES

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

When feeding without Power Feed 11 Cold Feedfeature, electrode and drive mechanism are hotto work and ground and could remain energized several seconds after the gun trigger is released.

Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform this installation.

Observe all additional Safety Guidelines detailed throughout this manual.

DRIVE ROLL KIT AND GUIDE TUBE INSTALLATION

1)Turn OFF Welding Power Source.

2)Pull open Pressure Door to expose rolls and wire guides.

3)Remove Outer Wire Guide by turning knurled thumb screws counter-clock-wise to unscrew them from Feed plate.

4)Remove drive rolls, if any are installed, by pulling straight off shaft. Remove inner guide.

Note: Not all Drive Roll and Wire Guide changes require changing the Gun Adapter Guide Tubes. See FAST-MATEGUN ADAPTER GUIDE TUBES in this section for the proper size guide tube required for the wire size to be used. If a guide tube change is NOT required skip Steps 5 & 6 And go to Step 7.

5)Loosen the small Knurled Knob on the Feedhead. This the Knurled Knob that is closest to the Gun Adapter and is used to secure the wire guide tube into the Gun Adapter.

6)Insert the new wire guide tube (either end, tube is symmetric) into the incoming end of the Gun Adapter (This will remove an existing tube if pre- sent) until it flush with the incoming end and re- tighten the small Knurled Knob.

POWER FEED 11

Image 16
Contents Safety Depends on You IM613-BSafety Electric Shock can kill Safety IiiPrécautions DE Sûreté Sûreté Pour Soudage a L’ArcThank You Table of Contents Section F Section EP315 Series Installation Power FeedSafety Precaution Wire Feeder to Power Source ConfigurationsHanging On the FloorCable Connections Wire Drive Gear Ratio High or LOW Speed Changing the Wire Drive RatioWork Cable Connections Selecting the Proper Gear Ratio CurrentRatio Change Procedure DIP Switch Setup Setting DIP Switches in the Control BOXSetting DIP Switches in the Wire Drive Figure A.4Drive Roll KIT and Guide Tube Installation Procedure to Install Drive Rolls and Guide TubesFAST-MATEGUN Adapter Guide Tubes GUN and Cable Assemblies Magnum GunsGUN Connection Guidelines General GuidelinesGmaw Shielding GAS Lifting HandleCylinder may explode if damaged Buildup of Shielding GAS may harm health or killGeneral Panel Installation Guidelines Optional Panels for Control BOXOperation K1542-4 CV/Gouge PanelStd Control Box Panels Lower PanelsK1542-11 MX2 PanelOptional K1640-1 Dual Procedure / Memory Door Panel Optional K1542-12 MSP2 Panel OptionalControl BOX Panels -- SET UP Controls Description Control BOX -- PC Board AdjustmentsControl BOX -- Using Operating Limits Control BOX -- Setting Operating LimitsWire Drive Operation Wire Drive Settings -- ExternalSTEP/4 Step Switch Cold Feed / GAS Purge SwitchWire Reel Loading READI-REELS, Spools or Coils Wire Drive -- PC Board AdjustmentsElectrode Polarity Gear BOX RatioGAS Guard Regulator Setting Feeding Electrode and Brake AdjustmentDrive Roll Pressure Setting Wire Feed Overload Protection Wire Reel ChangingMaking a Weld Component Status Lights Status Light StatesStatus Light States CON’T Accessories Wire Size Roll Drive Driven Solid Steel ElectrodeTable C.1 Drive Roll and Guide Tube Kits Cored ElectrodeDescription of Optional CON- Trol BOX Panels General Panel Installation GuidelinesK1543, K1544 and K1545 Input Cable Assemblies Wire Spindle Adapters K1536-1 Water Flow Sensor KITK659-1 GAS Guard Regulator K1649-1 Mounting Bracket HorizontalMaintenance MaintenanceWire Drive Motor and Gearbox Gun and Cable Maintenance1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideTroubleshooting Field Service Facility Possible Cause Recommended Symptoms Course of ActionYour local Lincoln Authorized Troubleshooting Possible Cause Course of ActionEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Possible Cause Err 001 Err 003Err 004 Err 005Err 020 Err 100Err 200 Err 201Err 211 Err 212Wiring Diagram Power Feed 11 Wire Feeder Diagrams Wiring DiagramL10834 Power Feed Basic Course $700.00Precaucion Warnung