Lincoln Electric IM613-B manual Setting DIP Switches in the Wire Drive, Figure A.4

Page 15

A-7

INSTALLATION

A-7

 

 

 

S2 DIP Switch Bank on Control Box Motherboard (For software version S24456-1)

Switch

Off

 

 

On

 

 

 

 

 

1

Network Group ID, MSB

(Assigns Control Box to a specific group) (Off is factory setting)

 

 

 

 

 

2

Network Group ID, LSB

(Assigns Control Box to a specific group ) (Off is factory setting)

 

 

 

 

3

4-Step Domestic Configuration

4-Step European Configuration

 

 

 

 

 

4

Power Feed 10 / Dual

 

 

Power Feed 11

 

 

 

 

5

Procedure change with trigger OFF

Procedure change with trigger ON

 

 

 

 

6

Must be off for normal operation

Adjust lower limits

 

 

 

 

7

Must be off for normal operation

Adjust upper limits

 

 

 

 

8

Must be on for all units (Permits selection of extended modes)

 

 

 

 

 

Note: the factory shipped settings for Switch S2 are as follows:

PF-11

European - Switches 1,2

& 5-7 OFF;

Switches 3,4,8 ON

PF-11

World

- Switches 1-3

& 5-7 OFF;

Switches 4, 8 ON

SETTING DIP SWITCHES IN THE WIRE

 

DRIVE

FIGURE A.4

 

There is one DIP switch bank on the control board of

 

the wire drive. Its labeled S1 and is located and ori-

 

ented as shown in Figure A.4.

S1

O N 1 2 3 4 5 6 7

8

S1 DIP Switch Bank on Wire Drive Control Board (For software version S24468-1)

Switch

Off

 

 

 

On

 

 

 

 

 

1

Network Group ID, MSB

(Assigns Wire Drive to a specific group)

 

 

 

 

 

2

Network Group ID, LSB

(Assigns Wire Drive to a specific group )

 

 

 

 

 

3

Network Feed Head ID, MSB

(Assigns feed head number to wire drive)

 

 

 

 

 

 

4

Network Feed Head ID

 

(Assigns feed head number to wire drive)

 

 

 

 

 

5

Network Feed Head ID, LSB

(Assigns feed head number to wire drive)

 

 

 

 

 

 

6

Spare

 

 

 

 

 

 

 

 

7

Electrode Sense Polarity = Positive

Electrode Sense Polarity = Negative

 

 

 

 

 

 

Switch position must match polarity of weld cable attached to feed plate.

8

Gear Box Ratio = Low

Gear Box Ratio = High

Switch position must match actual gear box ratio of wire drive.

Note: the factory shipped settings for Switches 1-7 is OFF, Switch 8 is ON.

POWER FEED 11

Image 15
Contents IM613-B Safety Depends on YouSafety Electric Shock can kill Iii SafetySûreté Pour Soudage a L’Arc Précautions DE SûretéThank You Table of Contents Section E Section FP315 Series Power Feed InstallationOn the Floor Safety PrecautionWire Feeder to Power Source Configurations HangingCable Connections Current Wire Drive Gear Ratio High or LOW SpeedChanging the Wire Drive Ratio Work Cable Connections Selecting the Proper Gear RatioRatio Change Procedure Setting DIP Switches in the Control BOX DIP Switch SetupFigure A.4 Setting DIP Switches in the Wire DriveProcedure to Install Drive Rolls and Guide Tubes Drive Roll KIT and Guide Tube InstallationFAST-MATEGUN Adapter Guide Tubes General Guidelines GUN and Cable AssembliesMagnum Guns GUN Connection GuidelinesBuildup of Shielding GAS may harm health or kill Gmaw Shielding GASLifting Handle Cylinder may explode if damagedOptional Panels for Control BOX General Panel Installation GuidelinesOperation Control Box Panels Lower Panels K1542-4 CV/Gouge PanelStdK1542-11 MX2 PanelOptional K1542-12 MSP2 Panel Optional K1640-1 Dual Procedure / Memory Door Panel OptionalControl BOX -- PC Board Adjustments Control BOX Panels -- SET UP Controls DescriptionControl BOX -- Setting Operating Limits Control BOX -- Using Operating LimitsCold Feed / GAS Purge Switch Wire Drive OperationWire Drive Settings -- External STEP/4 Step SwitchGear BOX Ratio Wire Reel Loading READI-REELS, Spools or CoilsWire Drive -- PC Board Adjustments Electrode PolarityFeeding Electrode and Brake Adjustment GAS Guard Regulator SettingDrive Roll Pressure Setting Wire Reel Changing Wire Feed Overload ProtectionMaking a Weld Status Light States Component Status LightsStatus Light States CON’T Cored Electrode AccessoriesWire Size Roll Drive Driven Solid Steel Electrode Table C.1 Drive Roll and Guide Tube KitsGeneral Panel Installation Guidelines Description of Optional CON- Trol BOX PanelsK1543, K1544 and K1545 Input Cable Assemblies K1649-1 Mounting Bracket Horizontal Wire Spindle AdaptersK1536-1 Water Flow Sensor KIT K659-1 GAS Guard RegulatorGun and Cable Maintenance MaintenanceMaintenance Wire Drive Motor and GearboxHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting Possible Cause Recommended Symptoms Course of Action Field Service FacilityYour local Lincoln Authorized Troubleshooting Course of Action Possible CauseEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Possible Cause Err 005 Err 001Err 003 Err 004Err 201 Err 020Err 100 Err 200Err 212 Err 211Wiring Diagram Power Feed 11 Wire Feeder Wiring Diagram DiagramsL10834 Power Feed $700.00 Basic CoursePrecaucion Warnung