MAINTENANCE / STORAGE
5.Replace air filter media in compressor filter housing.
6.Position air filter cover over air filter media. Use phillips screwdriver to secure cover with screw.
NOTE: Replace air filter media if it is extremely dirty.
Check Pump Intake and Exhaust Valves
Once each year, certain internal compressor components must be inspected. Have a trained service technician perform this check, to include the air compressor pump intake and exhaust valves.
Check Safety Labels
As often as desired or at least yearly, inspect all labels applied to the air compressor. All safety labels should be present and readable. Should any safety label be missing or illegible, obtain a replacement from an authorized service center or call the air compressor helpline at
Overload Protection Reset
This compressor is equipped with an overload protection feature that protects the motor if it overheats. If the compressor motor overheats and ‘trips’ this circuit breaker, wait 15 minutes for the motor to cool.Then push the RESET button located on the motor shroud (see Figure 10).
Figure 10 - Overload Protection RESET Button
RESETButton
Also see the Troubleshooting section on page 15 for more information.
STORAGE
Before you store your air compressor, make sure you perform the following:
1.Review “Maintenance” beginning on page 11 and perform scheduled maintenance as necessary.
2.Push ON - OFF switch to OFF and unplug unit.
3.Turn pressure control knob counterclockwise until knob turns freely.
4.Remove air tool or accessory.
WARNING
Compressed air stream from hose or tank drain can cause soft tissue damage to exposed skin and can propel objects leading to severe injury
and / or property damage.
•DO NOT direct air stream at self or others.
•Always wear ANSI Z87.1 approved safety glasses with side shields.
5.Pull ring on safety valve and drain air from air tank to reduce air pressure. Release safety valve ring.
6.Drain remaining air and water from tank by opening drain valves fully counterclockwise.
7.Rock unit forward and back to agitate condensate as it drains to obtain a more thorough emptying action.
8.After water has been drained, close drain valves fully clockwise.
9.Protect electrical cord and air hose from damage (such as being stepped on or driven over).
10.Store air compressor in clean, dry, indoor location.
14