Briggs & Stratton 074001 Storage, Check Pump Intake and Exhaust Valves, Check Safety Labels

Page 14

MAINTENANCE / STORAGE

5.Replace air filter media in compressor filter housing.

6.Position air filter cover over air filter media. Use phillips screwdriver to secure cover with screw.

NOTE: Replace air filter media if it is extremely dirty.

Check Pump Intake and Exhaust Valves

Once each year, certain internal compressor components must be inspected. Have a trained service technician perform this check, to include the air compressor pump intake and exhaust valves.

Check Safety Labels

As often as desired or at least yearly, inspect all labels applied to the air compressor. All safety labels should be present and readable. Should any safety label be missing or illegible, obtain a replacement from an authorized service center or call the air compressor helpline at 1-800-743-4115.

Overload Protection Reset

This compressor is equipped with an overload protection feature that protects the motor if it overheats. If the compressor motor overheats and ‘trips’ this circuit breaker, wait 15 minutes for the motor to cool.Then push the RESET button located on the motor shroud (see Figure 10).

Figure 10 - Overload Protection RESET Button

RESETButton

Also see the Troubleshooting section on page 15 for more information.

STORAGE

Before you store your air compressor, make sure you perform the following:

1.Review “Maintenance” beginning on page 11 and perform scheduled maintenance as necessary.

2.Push ON - OFF switch to OFF and unplug unit.

3.Turn pressure control knob counterclockwise until knob turns freely.

4.Remove air tool or accessory.

WARNING

Compressed air stream from hose or tank drain can cause soft tissue damage to exposed skin and can propel objects leading to severe injury

and / or property damage.

DO NOT direct air stream at self or others.

Always wear ANSI Z87.1 approved safety glasses with side shields.

5.Pull ring on safety valve and drain air from air tank to reduce air pressure. Release safety valve ring.

6.Drain remaining air and water from tank by opening drain valves fully counterclockwise.

7.Rock unit forward and back to agitate condensate as it drains to obtain a more thorough emptying action.

8.After water has been drained, close drain valves fully clockwise.

9.Protect electrical cord and air hose from damage (such as being stepped on or driven over).

10.Store air compressor in clean, dry, indoor location.

14

Image 14
Contents 074001 Equipment Description Table of ContentsSafety Rules Make this manual available to other users of this equipment Compressor can start any time when plugged Stay ClearUnpacking AssemblyCarton Contents Oil Fill Location Features and ControlsFeatures and Controls Add Oil Break-In ProcedureOperation OperationAir Compressor Operating Location Grounding InstructionsExtension Cords Starting Your Air CompressorStopping Your Air Compressor Compressor Operation Specifications / Maintenance Product SpecificationsMaintenance Fill in as you completeCheck Quick Connect Fittings and Tank Drain Valves Check Safety ValveMaintenance Check / Change Pump OilCleaning Unit Check / Clean Air FilterMaintenance / Storage Check Safety LabelsOverload Protection Reset StoragePressure switch does not shut off motor TroubleshootingTroubleshooting Before You CallHave checked by a trained service technician Let motor cool for 15 minutes. Press ResetTank pressure exceeds pressure switch Switch has not unloaded head pressureGlossary GlossaryPage Limited Warranty Règles DE Sécurité Table DES MatièresDescription DE L Équipement Règles DE SécuritéAvertissement Mise EN Garde ÉLOIGNEZ-VOUSContenu de la boîte AssemblageAssemblage DéballageEmplacement pour le remplissage d’huile La jauge d’huile Fonctions ET CommandesFonctions ET Commandes Raccords de connexion rapide Connectez ici les outilsProcédure de rodage OpérationAjoutez de l’huile Opération’UTILISEZ PAS UN Adaptateur DE Mise À LA Terre Emplacement du compresseur d’air lors de l’utilisationDirectives de mise à la terre Rallonges Démarrage de votre compresseur d’airArrêt de votre compresseur d’air Utilisation du compresseur Spécifications / Entretien SpécificationsEntretien Vérifiez/changez l’huile de la pompe EntretienVérifiez la soupape de sûreté Vérification du niveau d’huileEntretien général Nettoyage de l’unitéVérifiez/nettoyez le filtre à air Vérifiez les étiquettes de sécurité EntreposageEntretien / Entreposage Réarmement du protecteur de surchargeDépannage DépannageAvant de nous contacter ’interrupteur Marche Arrêt on OFF à la Le compresseur ne fournit pasSuffisamment d’air pour le Le moteur ne fonctionne pasGlossaire GlossaireRemarques Période DE Garantie Reglas DE Seguridad Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadAdvertencia Precaución Manténgase AlejadoContenido de la caja MontajeMontaje DesembalajeAcoplamientos para conector rápido Permiten conectar Características Y MandosCaracterísticas Y Mandos Bomba del compresor de aire La bomba comprime el aire enProcedimiento de preparación para el uso inicial OperaciónAñadir aceite OperaciónNo Utilice UN Adaptador DE Conexión a Tierra Colocación del compresorInstrucciones de conexión a tierra Cables prolongadores Puesta en marcha del compresor de aireParada del compresor de aire Uso del compresor El compresor debe estar conectado a tierraEspecificaciones / Mantenimiento EspecificacionesMantenimiento EscapeComprobar / cambiar el aceite de la bomba MantenimientoComprobar la válvula de seguridad Comprobación del nivel de aceiteMantenimiento general Limpieza de la unidadComprobar / limpiar el filtro de aire Comprobar las válvulas de admisión y escape de la bomba AlmacenamientoMantenimiento / Almacenamiento Comprobar las etiquetas de seguridadDiagnositicos DE Averías Diagnositicos DE AveríasAntes de llamar Accesorios El compresor no suministra aireSuficiente para accionar los El motor no funcionaGlosario GlosarioNotas Notas Período DE Garantía