TROUBLESHOOTING

PROBLEM

CAUSE

CORRECTION

 

1.

Prolonged excessive use of air.

1.

Decrease amount of air used.

 

2.

Compressor is not large enough for air

2.

Check the accessory requirement. If it is

 

 

requirement.

 

higher than the CFM or pressure supplied by

Compressor is not

 

 

 

your air compressor, you need a larger

 

 

 

capacity air compressor.

supplying enough air to

 

 

 

3.

Hole in hose.

3.

Check and replace if required.

operate accessories.

 

 

 

 

 

4.

Check valve restricted or leaks air.

4.

Remove and clean or replace check valve.

 

5.

Restricted air intake filter.

5.

Tighten fittings. Clean or replace air intake

 

 

 

 

filter (see page 13).

 

 

 

 

 

 

1.

Motor overload protection switch has

1.

Let motor cool for 15 minutes. Press RESET

 

 

tripped.

 

to reset overload switch.

 

2.

Tank pressure exceeds pressure switch

2.

Motor will start automatically when tank

 

 

“cut-in” pressure.

 

pressure drops below “cut-in” pressure

 

 

 

 

setting.

 

3.

Loose electrical connections.

3.

Check wiring connection inside pressure

 

 

 

 

switch and terminal box area.

 

4.

Possible defective motor or starting

4.

Have checked by a trained service technician.

 

 

capacitor.

 

 

 

5.

Pressure release valve on pressure

5.

Drain pressure by setting ON/AUTO - OFF

Motor will not run.

 

switch has not unloaded head pressure.

 

switch to OFF. If the valve does not open,

 

 

 

replace pressure switch.

 

 

 

 

 

6.

Fuse blown, circuit breaker tripped.

6A.

Check fuse box for blown fuse and replace as

 

 

 

 

necessary. Reset circuit breaker. DO NOT use

 

 

 

 

a fuse or circuit breaker with higher rating

 

 

 

 

than that specified for that branch circuit.

 

 

 

B.

Check for proper fuse. Use a time delay fuse.

 

 

 

C. Check for low voltage conditions and/or

 

 

 

 

proper extension cord.

 

 

 

D. Disconnect all other electrical loads from

 

 

 

 

circuit used by air compressor OR operate

 

 

 

 

air compressor on dedicated branch circuit.

 

 

 

 

 

16

Image 16
Contents 074001 Safety Rules Table of ContentsEquipment Description Make this manual available to other users of this equipment Compressor can start any time when plugged Stay ClearCarton Contents AssemblyUnpacking Features and Controls Features and ControlsOil Fill Location Break-In Procedure OperationAdd Oil OperationAir Compressor Operating Location Grounding InstructionsStopping Your Air Compressor Starting Your Air CompressorExtension Cords Compressor Operation Product Specifications MaintenanceSpecifications / Maintenance Fill in as you completeCheck Safety Valve MaintenanceCheck Quick Connect Fittings and Tank Drain Valves Check / Change Pump OilCleaning Unit Check / Clean Air FilterCheck Safety Labels Overload Protection ResetMaintenance / Storage StorageTroubleshooting TroubleshootingPressure switch does not shut off motor Before You CallLet motor cool for 15 minutes. Press Reset Tank pressure exceeds pressure switchHave checked by a trained service technician Switch has not unloaded head pressureGlossary GlossaryPage Limited Warranty Table DES Matières Description DE L ÉquipementRègles DE Sécurité Règles DE SécuritéAvertissement Mise EN Garde ÉLOIGNEZ-VOUSAssemblage AssemblageContenu de la boîte DéballageFonctions ET Commandes Fonctions ET CommandesEmplacement pour le remplissage d’huile La jauge d’huile Raccords de connexion rapide Connectez ici les outilsOpération Ajoutez de l’huileProcédure de rodage OpérationDirectives de mise à la terre Emplacement du compresseur d’air lors de l’utilisation’UTILISEZ PAS UN Adaptateur DE Mise À LA Terre Arrêt de votre compresseur d’air Démarrage de votre compresseur d’airRallonges Utilisation du compresseur Entretien SpécificationsSpécifications / Entretien Entretien Vérifiez la soupape de sûretéVérifiez/changez l’huile de la pompe Vérification du niveau d’huileVérifiez/nettoyez le filtre à air Nettoyage de l’unitéEntretien général Entreposage Entretien / EntreposageVérifiez les étiquettes de sécurité Réarmement du protecteur de surchargeAvant de nous contacter DépannageDépannage Le compresseur ne fournit pas Suffisamment d’air pour le’interrupteur Marche Arrêt on OFF à la Le moteur ne fonctionne pasGlossaire GlossaireRemarques Période DE Garantie Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad Reglas DE SeguridadAdvertencia Precaución Manténgase AlejadoMontaje MontajeContenido de la caja DesembalajeCaracterísticas Y Mandos Características Y MandosAcoplamientos para conector rápido Permiten conectar Bomba del compresor de aire La bomba comprime el aire enOperación Añadir aceiteProcedimiento de preparación para el uso inicial OperaciónInstrucciones de conexión a tierra Colocación del compresorNo Utilice UN Adaptador DE Conexión a Tierra Parada del compresor de aire Puesta en marcha del compresor de aireCables prolongadores Uso del compresor El compresor debe estar conectado a tierraEspecificaciones MantenimientoEspecificaciones / Mantenimiento EscapeMantenimiento Comprobar la válvula de seguridadComprobar / cambiar el aceite de la bomba Comprobación del nivel de aceiteComprobar / limpiar el filtro de aire Limpieza de la unidadMantenimiento general Almacenamiento Mantenimiento / AlmacenamientoComprobar las válvulas de admisión y escape de la bomba Comprobar las etiquetas de seguridadAntes de llamar Diagnositicos DE AveríasDiagnositicos DE Averías El compresor no suministra aire Suficiente para accionar losAccesorios El motor no funcionaGlosario GlosarioNotas Notas Período DE Garantía