Briggs & Stratton 074001 Air Compressor Operating Location, Grounding Instructions

Page 8

OPERATION

Air Compressor Operating Location

Locate the air compressor in a clean, dry and well-ventilated area for operation.The air compressor should be placed at least 12 inches (30 cm) away from walls or other obstructions that could interfere with airflow.

The air compressor pump and shroud are designed to allow for proper cooling.The ventilation openings on the compressor are necessary to maintain proper operating temperature. DO NOT place rags or containers on or near these openings.The air filter must be kept clear of obstructions that could reduce airflow to the air compressor.

If you have any problems with the operation of your air compressor, call the air compressor helpline at

1-800-743-4115.If calling for assistance, please have the model, revision, and serial number from the data tag available.

Grounding Instructions

1.The cord set and plug supplied with this unit contains a grounding pin.This plug MUST be used with a grounded outlet.

WARNING

Improper grounding can result in electrical shock.

DO NOT use grounding adapters.

DO NOT modify the plug provided. If it does not fit the available outlet, a qualified electrician should install a proper outlet.

A qualified electrician MUST make repairs to the cord set or plug.

2.Make sure power outlet being used has same configuration as air compressor’s plug (see Figure 4).

DO NOT USE A GROUND ADAPTER!

Figure 4 - Correctly Rated 15 AMP Power Duplex Outlet

3.Inspect plug and cord before each use. DO NOT use compressor if there are signs of damage.

4.If these grounding instructions are not completely understood, or if in doubt that air compressor is correctly grounded, have installation checked by a qualified electrician.

8

Image 8
Contents 074001 Equipment Description Table of ContentsSafety Rules Make this manual available to other users of this equipment Compressor can start any time when plugged Stay ClearUnpacking AssemblyCarton Contents Oil Fill Location Features and ControlsFeatures and Controls Break-In Procedure OperationAdd Oil OperationAir Compressor Operating Location Grounding InstructionsExtension Cords Starting Your Air CompressorStopping Your Air Compressor Compressor Operation Product Specifications MaintenanceSpecifications / Maintenance Fill in as you completeCheck Safety Valve MaintenanceCheck Quick Connect Fittings and Tank Drain Valves Check / Change Pump OilCleaning Unit Check / Clean Air FilterCheck Safety Labels Overload Protection ResetMaintenance / Storage StorageTroubleshooting TroubleshootingPressure switch does not shut off motor Before You CallLet motor cool for 15 minutes. Press Reset Tank pressure exceeds pressure switchHave checked by a trained service technician Switch has not unloaded head pressureGlossary GlossaryPage Limited Warranty Table DES Matières Description DE L ÉquipementRègles DE Sécurité Règles DE SécuritéAvertissement Mise EN Garde ÉLOIGNEZ-VOUSAssemblage AssemblageContenu de la boîte DéballageFonctions ET Commandes Fonctions ET CommandesEmplacement pour le remplissage d’huile La jauge d’huile Raccords de connexion rapide Connectez ici les outilsOpération Ajoutez de l’huileProcédure de rodage Opération’UTILISEZ PAS UN Adaptateur DE Mise À LA Terre Emplacement du compresseur d’air lors de l’utilisationDirectives de mise à la terre Rallonges Démarrage de votre compresseur d’airArrêt de votre compresseur d’air Utilisation du compresseur Spécifications / Entretien SpécificationsEntretien Entretien Vérifiez la soupape de sûretéVérifiez/changez l’huile de la pompe Vérification du niveau d’huileEntretien général Nettoyage de l’unitéVérifiez/nettoyez le filtre à air Entreposage Entretien / EntreposageVérifiez les étiquettes de sécurité Réarmement du protecteur de surchargeDépannage DépannageAvant de nous contacter Le compresseur ne fournit pas Suffisamment d’air pour le’interrupteur Marche Arrêt on OFF à la Le moteur ne fonctionne pasGlossaire GlossaireRemarques Période DE Garantie Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad Reglas DE SeguridadAdvertencia Precaución Manténgase AlejadoMontaje MontajeContenido de la caja DesembalajeCaracterísticas Y Mandos Características Y MandosAcoplamientos para conector rápido Permiten conectar Bomba del compresor de aire La bomba comprime el aire enOperación Añadir aceiteProcedimiento de preparación para el uso inicial OperaciónNo Utilice UN Adaptador DE Conexión a Tierra Colocación del compresorInstrucciones de conexión a tierra Cables prolongadores Puesta en marcha del compresor de aireParada del compresor de aire Uso del compresor El compresor debe estar conectado a tierraEspecificaciones MantenimientoEspecificaciones / Mantenimiento EscapeMantenimiento Comprobar la válvula de seguridadComprobar / cambiar el aceite de la bomba Comprobación del nivel de aceiteMantenimiento general Limpieza de la unidadComprobar / limpiar el filtro de aire Almacenamiento Mantenimiento / AlmacenamientoComprobar las válvulas de admisión y escape de la bomba Comprobar las etiquetas de seguridadDiagnositicos DE Averías Diagnositicos DE AveríasAntes de llamar El compresor no suministra aire Suficiente para accionar losAccesorios El motor no funcionaGlosario GlosarioNotas Notas Período DE Garantía