Briggs & Stratton 074001 Table of Contents, Equipment Description, Safety Rules

Page 2

SAFETY RULES

SAVE THESE INSTRUCTIONS

TABLE OF CONTENTS

Safety Rules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-4

Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

Features and Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

Operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-9

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-13

Storage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Glossary. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Français. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20-37

Espanõl . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38-56

EQUIPMENT DESCRIPTION

This manual contains operation and maintenance information for a twin tank single-stage air compressor that produces

5.1CFM at 40 PSI (2.8 bars) and 4.0 CFM at 90 PSI (6.2 bars) using an 120 Volt A.C. electric motor.This high quality system features a direct drive oil lube pump with cast iron sleeve, an easy start valve, and two air outlets.This unit also features a motor overload protection feature with manual restart.

Every effort has been made to ensure that information in this manual is accurate and current. However, we reserve the right to change, alter or otherwise improve the product and this document at any time without prior notice.

Statement of Use

This air compressor has been manufactured to provide an adequate volume of compressed air for operating a variety of light-duty air tools (hand grinders, nailers, ratchets, staplers), spraying equipment, and inflators requiring less than 5.1 CFM air flow for operation. Operate this compressor ONLY in an ambient temperature range from 32° to 95°F (0° to 35°C). This compressor is designed for a maximum of 70% duty per hour at full load.

Copyright © 2005 Briggs & Stratton Power Products Group, LLC. All rights reserved. No part of this material may be reproduced or transmitted in any form by any means without the express written permission of Briggs & Stratton Power Products Group, LLC.

SAFETY RULES

This is the safety alert symbol. It is used to alert you to potential personal injury hazards. Obey all safety messages that follow this symbol to avoid possible injury or death.

The safety alert symbol () is used with a signal word (DANGER, CAUTION,WARNING), a pictorial and/or a safety message to alert you to hazards. DANGER indicates a hazard which, if not avoided, will result in death or serious injury.WARNING indicates a hazard which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard which, if not avoided, might result in minor or moderate injury. CAUTION, when not used with the safety alert symbol (), indicates a situation that could result in equipment damage. Follow safety messages to avoid or reduce the risk of injury or death.

Hazard Symbols and Meanings

Air Injection

Auto-start

Compressed Air

Electrical Shock

Explosion

Fire

Flying Objects

Hot Surface

Inhalation

2

Image 2
Contents 074001 Equipment Description Table of ContentsSafety Rules Make this manual available to other users of this equipment Compressor can start any time when plugged Stay ClearUnpacking AssemblyCarton Contents Oil Fill Location Features and ControlsFeatures and Controls Add Oil Break-In ProcedureOperation OperationAir Compressor Operating Location Grounding InstructionsExtension Cords Starting Your Air CompressorStopping Your Air Compressor Compressor Operation Specifications / Maintenance Product SpecificationsMaintenance Fill in as you completeCheck Quick Connect Fittings and Tank Drain Valves Check Safety ValveMaintenance Check / Change Pump OilCleaning Unit Check / Clean Air FilterMaintenance / Storage Check Safety LabelsOverload Protection Reset StoragePressure switch does not shut off motor TroubleshootingTroubleshooting Before You CallHave checked by a trained service technician Let motor cool for 15 minutes. Press ResetTank pressure exceeds pressure switch Switch has not unloaded head pressureGlossary GlossaryPage Limited Warranty Règles DE Sécurité Table DES MatièresDescription DE L Équipement Règles DE SécuritéAvertissement Mise EN Garde ÉLOIGNEZ-VOUSContenu de la boîte AssemblageAssemblage DéballageEmplacement pour le remplissage d’huile La jauge d’huile Fonctions ET CommandesFonctions ET Commandes Raccords de connexion rapide Connectez ici les outilsProcédure de rodage OpérationAjoutez de l’huile Opération’UTILISEZ PAS UN Adaptateur DE Mise À LA Terre Emplacement du compresseur d’air lors de l’utilisationDirectives de mise à la terre Rallonges Démarrage de votre compresseur d’airArrêt de votre compresseur d’air Utilisation du compresseur Spécifications / Entretien SpécificationsEntretien Vérifiez/changez l’huile de la pompe EntretienVérifiez la soupape de sûreté Vérification du niveau d’huileEntretien général Nettoyage de l’unitéVérifiez/nettoyez le filtre à air Vérifiez les étiquettes de sécurité EntreposageEntretien / Entreposage Réarmement du protecteur de surchargeDépannage DépannageAvant de nous contacter ’interrupteur Marche Arrêt on OFF à la Le compresseur ne fournit pasSuffisamment d’air pour le Le moteur ne fonctionne pasGlossaire GlossaireRemarques Période DE Garantie Reglas DE Seguridad Tabla DE ContenidosDescripción DEL Equipo Reglas DE SeguridadAdvertencia Precaución Manténgase AlejadoContenido de la caja MontajeMontaje DesembalajeAcoplamientos para conector rápido Permiten conectar Características Y MandosCaracterísticas Y Mandos Bomba del compresor de aire La bomba comprime el aire enProcedimiento de preparación para el uso inicial OperaciónAñadir aceite OperaciónNo Utilice UN Adaptador DE Conexión a Tierra Colocación del compresorInstrucciones de conexión a tierra Cables prolongadores Puesta en marcha del compresor de aireParada del compresor de aire Uso del compresor El compresor debe estar conectado a tierraEspecificaciones / Mantenimiento EspecificacionesMantenimiento EscapeComprobar / cambiar el aceite de la bomba MantenimientoComprobar la válvula de seguridad Comprobación del nivel de aceiteMantenimiento general Limpieza de la unidadComprobar / limpiar el filtro de aire Comprobar las válvulas de admisión y escape de la bomba AlmacenamientoMantenimiento / Almacenamiento Comprobar las etiquetas de seguridadDiagnositicos DE Averías Diagnositicos DE AveríasAntes de llamar Accesorios El compresor no suministra aireSuficiente para accionar los El motor no funcionaGlosario GlosarioNotas Notas Período DE Garantía