Briggs & Stratton 074001 Check Safety Valve, Check Quick Connect Fittings and Tank Drain Valves

Page 12

MAINTENANCE

Check Safety Valve

1.Pull ring on safety valve (see Figure 6) and observe that safety valve operates freely.

Figure 6 - Safety Valve

Safety Valve Ring

Pressure Switch

2.If valve is stuck or does not operate smoothly, it must be replaced with same type of valve.Take unit to authorized service facility for repair.

Check Quick Connect Fittings and Tank Drain Valves

1.Push ON - OFF switch to OFF and unplug unit.

2.Disconnect air tool or accessory from unit.

3.Pull ring on safety valve to reduce air pressure. Release safety valve ring.

WARNING

Compressed air stream from hose or tank drain can cause soft tissue damage to exposed skin and can propel objects leading to severe injury

and / or property damage.

DO NOT direct air stream at self or others.

Always wear ANSI Z87.1 approved safety glasses with side shields.

4.Open both drain valves (turn fully counterclockwise, see Figure 3, earlier) and permit accumulated water to be discharged.Valves should operate smoothly and have full range of operation.

5.After water has drained, close drain valves fully clockwise.

NOTE: If drain valves are plugged, pull safety valve ring to fully drain air from tank. Remove, clean and reinstall drain valve.

Check / Change Pump Oil

Checking Oil Level

Use these steps to check oil level:

1.Push ON - OFF switch to OFF and unplug unit.

2.Place unit on a flat, level surface.

3.Remove oil dipstick and wipe dipstick with clean cloth.

4.Reinstall dipstick into oil fill opening.

5.Carefully remove dipstick and verify that oil level is at proper level (see Figure 7).

6.If oil level is too low, add recommended oil to proper level (see Figure 7). If oil is above MAXIMUM oil level, remove excess oil, as described in next section.

Figure 7 - Oil Fill Information

Inset of

Dipstick

Oil Fill

Location

MAXIMUM

Oil Level

PROPER

Oil Level

Drain Plug

7.Reinstall oil dipstick.

Changing Oil

At recommended oil change interval, follow these steps:

1.Push ON - OFF switch to OFF and unplug unit.

2. Place unit on a flat, level surface.

WARNING

Operating air compressor and tubing are HOT and can cause burns.

DO NOT touch compressor or tubing.

Allow compressor to cool before servicing.

3.Remove oil dipstick and wipe dipstick with clean cloth.

4.Position a suitable container under oil drain plug to collect drain oil.

5.Use an adjustable wrench to remove hex head drain plug.

12

Image 12
Contents 074001 Table of Contents Safety RulesEquipment Description Make this manual available to other users of this equipment Compressor can start any time when plugged Stay ClearAssembly Carton ContentsUnpacking Features and Controls Features and ControlsOil Fill Location Break-In Procedure OperationAdd Oil OperationAir Compressor Operating Location Grounding InstructionsStarting Your Air Compressor Stopping Your Air CompressorExtension Cords Compressor Operation Product Specifications MaintenanceSpecifications / Maintenance Fill in as you completeCheck Safety Valve MaintenanceCheck Quick Connect Fittings and Tank Drain Valves Check / Change Pump OilCleaning Unit Check / Clean Air FilterCheck Safety Labels Overload Protection ResetMaintenance / Storage StorageTroubleshooting TroubleshootingPressure switch does not shut off motor Before You CallLet motor cool for 15 minutes. Press Reset Tank pressure exceeds pressure switchHave checked by a trained service technician Switch has not unloaded head pressureGlossary GlossaryPage Limited Warranty Table DES Matières Description DE L ÉquipementRègles DE Sécurité Règles DE SécuritéAvertissement Mise EN Garde ÉLOIGNEZ-VOUSAssemblage AssemblageContenu de la boîte DéballageFonctions ET Commandes Fonctions ET CommandesEmplacement pour le remplissage d’huile La jauge d’huile Raccords de connexion rapide Connectez ici les outilsOpération Ajoutez de l’huileProcédure de rodage OpérationEmplacement du compresseur d’air lors de l’utilisation Directives de mise à la terre’UTILISEZ PAS UN Adaptateur DE Mise À LA Terre Démarrage de votre compresseur d’air Arrêt de votre compresseur d’airRallonges Utilisation du compresseur Spécifications EntretienSpécifications / Entretien Entretien Vérifiez la soupape de sûretéVérifiez/changez l’huile de la pompe Vérification du niveau d’huileNettoyage de l’unité Vérifiez/nettoyez le filtre à airEntretien général Entreposage Entretien / EntreposageVérifiez les étiquettes de sécurité Réarmement du protecteur de surchargeDépannage Avant de nous contacterDépannage Le compresseur ne fournit pas Suffisamment d’air pour le’interrupteur Marche Arrêt on OFF à la Le moteur ne fonctionne pasGlossaire GlossaireRemarques Période DE Garantie Tabla DE Contenidos Descripción DEL EquipoReglas DE Seguridad Reglas DE SeguridadAdvertencia Precaución Manténgase AlejadoMontaje MontajeContenido de la caja DesembalajeCaracterísticas Y Mandos Características Y MandosAcoplamientos para conector rápido Permiten conectar Bomba del compresor de aire La bomba comprime el aire enOperación Añadir aceiteProcedimiento de preparación para el uso inicial OperaciónColocación del compresor Instrucciones de conexión a tierraNo Utilice UN Adaptador DE Conexión a Tierra Puesta en marcha del compresor de aire Parada del compresor de aireCables prolongadores Uso del compresor El compresor debe estar conectado a tierraEspecificaciones MantenimientoEspecificaciones / Mantenimiento EscapeMantenimiento Comprobar la válvula de seguridadComprobar / cambiar el aceite de la bomba Comprobación del nivel de aceiteLimpieza de la unidad Comprobar / limpiar el filtro de aireMantenimiento general Almacenamiento Mantenimiento / AlmacenamientoComprobar las válvulas de admisión y escape de la bomba Comprobar las etiquetas de seguridadDiagnositicos DE Averías Antes de llamarDiagnositicos DE Averías El compresor no suministra aire Suficiente para accionar losAccesorios El motor no funcionaGlosario GlosarioNotas Notas Período DE Garantía