QTechnical Data
Input voltage: | |||
Starting current: | < 25 A | ||
Input current: | max. 0.6 A (Effective value) | ||
Power |
|
|
|
consumption: | 55 W | ||
Return current*: | < 5 mA (no AC input) | ||
Nominal voltage: | 12 V DC |
|
|
| |||
Nominal current: | 0,8 / 3,6 A | ||
Charging voltage: | 14.4 V ± 0.25 V or | ||
| 14.7 V ± 0.25 V | ||
Charging current: | max. 3.6 A (3.6 A ± 10 % or | ||
| 0.8 A ± 10 %) | ||
Noise value**: | max. 150 mV | ||
Battery type: | 12 V lead acid battery | ||
| 1.2 Ah - 120 Ah | ||
Type of housing |
|
|
|
protection: | IP 65 (dustproof, waterproof) | ||
Dimensions: | 180 x 62 x 40 mm | ||
| (L x W x H) | ||
Weight: | 0.5 kg approx. | ||
Noise level: | < 50 dB (A) (tested from a | ||
| distance of 50 cm) |
*= Return current is the current used by the charging station battery, when no mains cur- rent is connected.
**= Noise value is the disturbance of current and voltage.
WARNING! Explosive gases - prevent | T4X | KH 3157 |
|
| |
flames and sparks. Before charging, | ||
study instruction sheet. Disconnect | 12 V DC | 0,8 / 3,6 A · IP65 |
supply before making or breaking | Polarity: red clamp (+), black clamp | |
battery connections. Provide for good |
|
|
ventilation. |
|
|
| Date of manufacture: 02/2008 |
Kompernaß GmbH · D- 44867 Bochum · Germany · www.kompernass.com
Introduction / Safety
QSafety
Safety information
mDanger! Avoid danger to life and limbs
caused by improper use!
JDo not operate the appliance with a damaged
cable, power cord or plug.
mCAUTION! A damaged power cord causes danger to life by electric shock.
JIf damaged, have the power cord j repaired by authorised and trained technicians only! Please contact the service department for your country!
JDo not allow toddlers or children
near the charging station without
the potential danger in the handling of electrical equipment.
JExplosion hazard! Protect your-
self from a highly explosive oxyhydro- gen gas reaction! Gaseous hydrogen
can leak from the battery during the charging and discharging process. Oxyhydrogen gas is an explosive mixture of gaseous hydrogen and oxygen. The result is the
JDanger of explosion and fire! Make sure that explosive and flam- mable substances e.g. petrol or sol-
vents can be ignited when using the charging station!
mDanger of chemical burns! Protect your eyes and skin against chemical burns caused by acid (sulphuric acid) upon contact with the battery! Do not look directly at the connected battery and use the following: