TIMER OPERATION

Before using the timer function, be sure that the Remote Controller is set to the correct current time (P. 5).

To Use the ON timer or OFF timer

1

Press the START/STOP button (Fig. 6 Q)

(if the unit is already operating, proceed to step 2).

 

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

2

Press the TIMER MODE button (Fig. 6 N) to select the

OFF timer or ON timer operation.

 

Each time the button is pressed the timer function changes in the follow-

 

ing order:

 

 

 

 

 

 

 

CANCEL

 

OFF

ON

 

 

 

 

 

 

PROGRAM(OFF ON, OFF ON)

The indoor unit’s greenTIMER Indicator Lamp (Fig. 3 6) will light.

3

Use the TIMER SET buttons (Fig. 6 O) to adjust the

desired OFF time or ON time.

Set the time while the time display is flashing (the flashing will continue for about five seconds).

button: Press to advance the time. button: Press to reverse the time.

About five seconds later, the entire display will reappear.

To Cancel the Timer

Use the TIMER button to select “CANCEL”. The air conditioner will return to normal operation.

To Change the Timer Settings

Perform steps 2 and 3.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed,Thermostat Setting, SUPER QUIET mode), after making the timer setting wait until the entire display reappears, then press the appropriate buttons to change the operating condition desired.

To Use the Program timer

1

Press the START/STOP button (Fig. 6 Q).

(if the unit is already operating, proceed to step 2).

The indoor unit’s OPERATION Indicator Lamp (red) (Fig. 3 5) will light.

To Cancel the Timer

Use the TIMER MODE button to select “CANCEL”.

The air conditioner will return to normal operation.

2

Set the desired times for OFF timer and ON timer.

See the section “To Use the ON timer or OFF timer” to set the desired

 

mode and times.

 

About three seconds later, the entire display will reappear.

 

The indoor unit’sTIMER Indicator Lamp (green) (Fig. 3 6) will light.

3

Press the TIMER MODE button (Fig. 6 N) to select the

PROGRAM timer operation (OFF

 

ON or OFF

 

ON

 

 

will display).

The display will alternately show “OFF timer” and “ON timer”, then change to show the time setting for the operation to occur first.

The program timer will begin operation. (If the ON timer has been selected to operate first, the unit will stop operating at this point.)

About five seconds later, the entire display will reappear.

About the Program timer

The program timer allows you to integrate OFF timer and ON timer operations in a single sequence.The sequence can involve one transition from OFF timer to ON timer, or from ON timer to OFF timer, within a twenty-four hour period.

The first timer function to operate will be the one set nearest to the current time.

The order of operation is indicated by the arrow in the Remote Controller’s Display (OFF ON, or OFF ON).

One example of Program timer use might be to have the air conditioner automati- cally stop (OFF timer) after you go to sleep, then start (ON timer) automatically in the morning before you arise.

To Change the Timer Settings

1.Follow the instructions given in the section “To Use the ONTimer or OFFTimer” to se- lect the timer setting you wish to change.

2.Press the TIMER MODE button to select either OFF ON or OFF ON.

To Stop Air Conditioner Operation while the Timer is Operating

Press the START/STOP button.

To Change Operating Conditions

If you wish to change operating conditions (Mode, Fan Speed, Thermostat Setting, SU- PER QUIET mode), after making the timer setting wait until the entire display reap- pears, then press the appropriate buttons to change the operating condition desired.

En-8

9315345363_OM.indb Sec1:8

9/16/2010 2:48:50 PM

Image 9
Contents Español Français English Operating Manual Mode D’EMPLOI Manual DE FuncionamientoSafety Precautions ContentsFeatures and Functions Maintenance Filter Reset Thermo SensorEn-2 En-3 Name of PartsIndoor Unit Operating Control Panel Fig Manual Auto button En-4En-5 PreparationEn-6 OperationEn-7 About Mode OperationTo Stop Operation Press the START/STOP button Q About Auto Changeover OperationEn-8 Timer OperationAbout the Sleep Timer Sleep Timer OperationManual Auto Operation En-9Adjusting the Direction of AIR Circulation Types of Air flow Direction SettingEn-10 En-11 Swing OperationTo select Swing Operation Press the Swing button T About Swing OperationEn-12 Cleaning and CareInstall the two Air filters and close the Intake Grille Install the Air cleaning filter set setReplacing dirty Air cleaning filters Replace them by two new Air cleaning filtersSymptom Problem TroubleshootingEn-14 NormalSymptom Items to check Event of Power InterruptionOperating Tips En-15Temperature and Humidity Range SpecificationCooling Mode Dry Mode Outdoor temperature Indoor temperature About 64 to 90 FPrécautions DE Sécurité SommaireFr-1 ’utilisez pas de gaz inflammables à près du climatiseurCaractéristiques ET Fonctions Fr-2Capteur Thermique Thermo Sensor Fr-3 Nomenclature DES OrganesManual Auto Fr-4Fr-5 PréparatifsFonctionnement Pour choisir le mode souhaitéFr-6 Réglage du thermostat Appuyez sur la touche SET TEMP. fig LPropos du mode de fonctionnement Fr-7Arrêt du climatiseur Appuyez sur la touche START/STOP Q Fr-8 Fonctionnement PAR Minuterie DE ProgrammationFonctionnement Temporisé Fonctionnement MANUEL-AUTOMATIQUEFr-9 Réglage DE LA Direction DU Flux D’AIR Fr-10Positions de réglage de direction du flux d’air Propos du mode oscillant Swing Fonctionnement OscillantFr-11 Fr-12 Nettoyage ET EntretienNettoyez la poussière avec un aspirateur ou en lavant Nettoyez à l’eauFr-13 Remplacement de filtres de nettoyage d’air salesRemplacez-les par deux nouveaux filtres De nettoyage d’air Remarques sur les filtres de nettoyage d’airFr-14 Guide DE DépannageSymptôme Problème Voyez FonctionsFr-15 Conseils D’UTILISATIONRemise en marche automatique En cas de coupure de courantFr-16 SpécificationsPlage de température et d’humidité Température intérieure Environ 64 à 90 FPrecauciones DE Seguridad ÍndiceEs-1 No emplee gases inflamables cerca del acondicionador de aireEs-2 Características Y FuncionesEs-3 Denominación DE LOS ComponentesBotón de control del ventilador Es-4Es-5 PreparativosEs-6 FuncionamientoPara seleccionar el modo de funcionamiento Para ajustar el termostatoNotas sobre el funcionamiento de los modos Es-7Refrigeración DeshumectaciónEs-8 Funcionamiento CON TemporizadorEs-9 Funcionamiento Manual Y AutomáticoPara cambiar los ajustes del tiempo Notas sobre el temporizador de desconexión automática SleepAjuste DE LA Dirección DE Circulación DEL Aire Es-10Tipos de ajustes de la dirección del flujo de aire Funcionamiento DE Vaivén Es-11Observaciones sobre el funcionamiento del vaivén Es-12 Limpieza Y MantenimientoSustitución de los filtros de limpieza de aire sucios Es-13Sustitúyalos dos filtros de limpieza de Aire nuevos Acerca de los filtros de limpieza de aireLocalización DE Averías Síntoma Problema Vea la PáginaEs-14 FuncionesEs-15 Consejos Para EL FuncionamientoReinicio automático En el caso de una interrupción de la alimentaciónEs-16 EspecificaciónMargen de temperatura y humedad Temperatura interior Aprox a 90 F9315345363OM.indb 16/2010 24904 PM 9315345363OM.indb 16/2010 24904 PM 9315345363OM.indb 16/2010 24904 PM