Change during operation: N = impossible, Y* = possible (enabled by using
FUNC DATA
), Y= possible (enabled by using )
E: Extension Terminal Functions
Func- |
|
|
|
|
| Change |
| |
tion |
|
|
| Min. | Factory | User | ||
Name | Setting range | Unit | during | |||||
code | unit | setting | setting | |||||
|
|
| operation | |||||
No. |
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
E01 | X1 terminal function | Use the code values listed below to se- | - | - | 0 | N |
| |
| X2 terminal function | lect [X1], [X2] and [X3] terminal func- |
|
|
|
|
| |
E02 | - | - | 2 | N |
| |||
| X3 terminal function | tions. |
|
|
|
|
| |
E03 | - | - | 3 | N |
| |||
|
| 0: Multistep frequency 1 (SS1) |
|
|
|
|
| |
|
| 1: Multistep frequency 2 (SS2) |
|
|
|
|
| |
|
| 2: |
|
|
|
|
| |
|
| 3: Alarm reset (RST) |
|
|
|
|
| |
|
| 4: External alarm (THR) |
|
|
|
|
| |
|
| 5: Write enable command for keypad |
|
|
|
|
| |
|
|
|
|
|
|
| ||
|
| 6: PID control cancel (Hz/PID) |
|
|
|
|
| |
|
| 7: Link operation selection (LE) |
|
|
|
|
| |
|
|
|
|
|
|
|
|
C: Control Functions of Frequency
Func- |
|
|
|
| Factory | Change |
| |
tion | Name | Setting range |
| Min. | User | |||
Unit | during | |||||||
code | unit | setting | setting | |||||
|
|
| operation | |||||
No. |
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
C01 | Jump frequency 1 | 0 to 120Hz | Hz | 1 | 0 | Y |
| |
C02 | 2 |
|
| 1 | 0 | Y |
| |
C03 | 3 |
|
| 1 | 0 | Y |
| |
C04 | (Hysteresis) | 0 to 30Hz | Hz | 1 | 3 | Y |
| |
C05 | Multistep frequency 1 | 0.0 to 120Hz | Hz | 0.1 | 0.0 | Y |
| |
C06 | 2 |
|
| 0.1 | 0.0 | Y |
| |
|
|
|
|
|
|
|
| |
C07 | 3 |
|
| 0.1 | 0.0 | Y |
|