Henny Penny OFG-390 manual Electrical, Requirements

Page 20

 

Model OFG- 390

2-9. ELECTRICAL

The gas fryer requires 120 volt, single phase 60 Hertz, 10

REQUIREMENTS

amp, 3 wire grounded (earthed) service, or 230 volt, single phase,

 

50 Hertz service. The 120 volt gas fryer is factory equipped with a

 

grounded (earthed) cord and plug for your protection against

 

shock, and should be plugged into a 3 prong grounded (earthed)

 

receptacle. Do not cut or remove grounding (earthing) prong. A

 

wiring diagram is located behind the right side panel, and can be

 

accessed by removing the side panel. The 230 volt plug must

 

conform to all local, state, and national codes.

To avoid electrical shock, do not disconnect the ground (earth) plug. This fryer must be adequately and safely grounded (earthed). Refer to local electrical codes for correct grounding (earthing) procedures or in absence of local codes, with The National Electrical Code, ANSI/NFPA No. 70-(the current edition). In Canada, all electrical connections are to be made in accordance with CSA C22.1, Canadian Electrical Code Part 1, and/or local codes.

To avoid electrical shock, this appliance must be equipped with an external circuit breaker which will disconnect all ungrounded (unearthed) conductors. The main power switch on this appliance does not disconnect all line conductors.

2-10

703

Image 20
Contents OPERATOR’S Manual Page Limited Warranty for Henny Penny Equipment Keep appliance area free and clear from combustibles Datos Tecnicos Para Products CE Specifications Henny Penny Head GAS Open FryerTable of Contents Assistance IntroductionProper Care Safety Hazardous Situation WHICH, if notAVOIDED, will Result in Death or Serious InjuryPage Installation Unpacking InstructionsRemove the counterweights from the pallet, which are UnpackingInstructions Strapped to the pallet, under the fryerOptional Ramp Unloading Model OFG 908 Position and install fryer to prevent tipping or move SelectingLocation Ment. Restraining ties may be used for stabilizationVentilation of Fryer GAS SupplyDuring any pressure testing of the gas supply piping Fryer must be isolated from the gas supply pipingSystem by closing its individual manual shutoff valve System at test pressures equal to or less than 1/2Model OFG 303 GAS Pressure Regulator SettingGAS Leak Test Electrical RequirementsModel OFG Page Operation Operating Components Airflow Switch High LimitIgnition Modules Spark IgnitorsSwitches IndicatorsLID Operation Melt CycleSwitches Indicators Although the Displaywillread CoolDuring the Standby MODE, the Shorten ING is HOT and will Cause BurnsSMS Controls Filling or Adding Shortening Basic Operation Cool Care Shortening Which could Result in Serious BurnsPersonal INJURY, FIRE, AND/OR Property With Prolonged USE, the FlashpointTurn COOK/PUMP switch to OFF position Filtering of ShorteningCloth or Glove When Tightening SHORTENING, IT’S Possible That the FilterConnection AT the Union on the Filter Tube is not Tightened PROPERLY. if SOLightingand Shutdown of the Burners Cleaning the Frypot Reset Regular MaintenanceFilter Pump Motor PROTECTOR-MANUALLubricating Lid Rollers -Annually Preventive MaintenanceCleaning the Nylatrons Monthly Preventive MaintenancProgramming CodeAfter the proportional control, press and release Special Program Mode Reset UsageProgramming Review UsageFactory Presets F/C, Gas/Electric, Speaker Volume Speaker Frequency, Codes, Initialize SystemTech I/O Mode Appliance TestMode Special ProgramHeat Control Troubleshooting Trouble Shooting Guide Problem Cause CorrectionError Codes Display Cause Panel Board Correction303 O S S a R Y Model OFG Shortening level also referred to as fill lines Gas fryers only See ignition modules Henny Penny Corp., Eaton, Ohio 45320, Revised